DTP T USW 333 • Setup Guide

This guide provides instructions for an experienced installer to set up and operate the 
Extron DTP T USW 333 switching video transmitter. The DTP T USW 333 transmitter switches among 
an analog video and two digital (HDMI) video inputs and, paired with a compatible receiver, can 
extend the selected signal up to 330 feet (100 m). If the selected input is HDMI, the extended video 
signal is HDCP-compliant.

Installation

Step 1 — Mounting

Turn off or disconnect all equipment power sources and mount the transmitter as required.

Step 2 — Making Connections

Inputs

a

 

Input 1 (RGB) connector

 — Connect a VGA cable

 

between this port and the VGA output port of the analog video

 

source.

b

 

Input 2 and 3 (HDMI) connectors

 — Connect HDMI cables

 

between these ports and the HDMI output ports of the digital video

 

sources.

NOTE:

 

See the 

LockIt

®

 Lacing Brackets

 on page 3 of this guide to securely fasten the HDMI connectors to the transmitter.

c

 

Audio input

 — Connect an unbalanced stereo audio source to this 3.5 mm mini stereo jack for an analog audio input.

NOTE:

 

Audio is not embedded in the HDMI signal; it is transmitted simultaneously and is present on all inputs.

Over DTP RS-232 and IR pass-through

d

 

RS-232 and IR connector

 — To pass serial or infrared data or control signals on the Over 

DTP RJ-45 output, connect the controlling device to the transmitter via the RS-232 and IR 
captive screw connector. Connect the device to be controlled to the receiver.

DTP output to receiver

ATTENTION:

  Do not connect this device to a computer data or telecommunications network.

e

 

DTP RJ-45 connector

 — Connect the transmitter DTP Out port to the DTP In port on the receiver. Extron 

recommends that you terminate both cable ends in accordance with the following specifications, at a 
minimum:

• 

TIA/EIA T 568B 

 

CAT 6a, shielded

• 

24 AWG, solid conductor

Signal LED

 — Lights when the unit is outputting a TMDS clock signal on the DTP output.

Link LED

 — Lights when a valid link is established between the units on the DTP cable.

Remote control

f

 

Remote Contact port

 — If desired, for contact closure control, plug a locally-constructed contact closure control device into this 

3.5 mm, 4-pole captive screw port. Momentarily short the pin for the desired input (1, 2, or 3) to G to select that input. To force an 
input to be always selected, leave the short in place.

NOTES:

• 

Contact closure control overrides front panel input selections.

• 

For contact closure control, auto-input switching mode must be off (see 

Selecting the switch mode

 on the next page).

POWER

12V
         

2

--A MAX

Rx

G

Tx

Rx

Tx

G

RS-232 

IR

Rx

Tx

1

RGB, Y, R-Y, B-Y

HDMI

HDMI

SIG                 LINK

DTP OUT

AUDIO

CONTACT

RS-232

TALLY

3

1

2 3 G

1

2 3 +V

RESET

INPUTS

OVER DTP

REMOTE

4

6

10

5

1

2

9

2

3

8

7

5

Pin

1

2

3

6

7

8

4

Wire color

White-green

Green

White-orange

White-blue

Orange

White-brown

Brown

Blue

TIA/EIA T

568B

TP Wires

12345678

Pins:

Tx

Rx

Rx

Tx

Gnd

Gnd

IR Device

RS-232 Device

Rx

Tx

Rx

Tx
G

RS-232 

IR

OVER DT

P

Reviews: