Extron electronics DTP T USW 333 Setup Manual Download Page 2

2

 

DTP T USW 333 • Setup Guide (Continued)

g

 

Remote Tally port

 — If desired, to remotely identify the currently selected input, plug a locally-constructed device into this 3.5 mm, 

4-pole captive screw connector. Connect the power wire for the device into the +V pin and connect the ground wire for the each 
indicator into the corresponding tally output pin: 1, 2, or 3.
When an input is selected, by either contact closure or front panel selection, the corresponding tally output pin shorts to ground, 
closing the circuit and lighting the connected indicator (LED).

h

 

Remote RS-232 port

 — Plug a serial RS-232 device into the switching transmitter via this rear 

panel 3.5 mm, 3-pole captive screw connector for remote control of the switching transmitter.

Reset button

i

 

Reset button

 — This button initiates two levels of reset. For different reset levels, use an 

Extron Tweeker or small screwdriver to press and hold the recessed button either while the 
switcher is running or while applying power. See the 

DTP T USW 333 User Guide

, available at 

www.extron.com

, for details.

Power

j

 

Power connector 

— Connect an IEC power cord between the included 12 VDC 

power supply and a 100-240 VAC, 50-60 Hz source. Connect the power supply to 
either unit, transmitter or receiver, as shown at right. Use the included tie-wrap to 
strap the cord to the captive screw connector.

NOTE:

 

Only one power supply is required. A single power supply connected to 

either unit in the pair powers both units. A power supply is included with the 
transmitter.

Front panel Configuration port

a

 

Configuration port

 — Plug a PC or other controlling device into the switching transmitter via this front 

panel mini-USB connector for remote configuration of the switching transmitter.

Operation

Switching inputs

Select the desired input by pressing the associated input button. Observe that the 
LED for the selected input lights.

NOTE:

  The switcher must be in normal (manual) mode (see below).

Selecting the switch mode

In auto-input switching mode, the switcher selects to the highest numbered input 
with a sync signal present. Turn auto-input switching mode on and off as follows:

1. 

Press and hold the Mode (Input 1) button.

2. 

Press and release the button  for the desired mode:

Auto (Input 3)

 — The Auto Switch LED lights.

Normal (Input 2)

 — The Auto Switch LED goes off.

3. 

Release the Mode button.

Locking and unlocking the front panel 
(Executive mode)

The switcher has a front panel lock feature that locks the front panel. If you try to make 
front panel input selections when the panel is locked, all front panel LEDs flash three 
times. Toggle the front panel lock on and off by pushing and holding all three Input 
buttons simultaneously for 5 seconds. All front panel LEDs flash three times. 
Release the buttons.

Interpreting the Status LEDs

Signal LEDs (1 through 3)

 —Indicate that the switcher detects horizontal sync 

(Signal LED 1) or TMDS clock (Signal LED 2 and Signal LED 3) signals on the associated input.

HDCP LEDs (2 and 3)

 —Indicate that the corresponding input signal is HDCP encrypted.

Power Supply

Output Cord

Ridges

Smooth

Captive

Screw

Connector

 3"
16 (5 mm) Max.

SECTION  A–A

A

A

REMOT

E

Rx

Tx

Gnd

RS-232 Device

G

Rx

Tx

RS-232

V

AUTO

SWITCH

CONFIG

1

1

2

3

MODE

NORMAL

AUTO

Press the button.
The LED lights 

green

.

1

2

3

MODE

NORMAL

AUTO

AUTO

SWITCH

Press and 

HOLD

 the Mode button.

Press and release the Auto or Normal button.

Release the Mode button.

Auto Switch lights (auto)
or goes out (normal).

1

2

3

MODE

NORMAL

AUTO

Press the and 

HOLD

 the all three Input buttons.

All three LEDs flash three times. Release the Input buttons.

HDCP

SIGNAL

STATUS

1

2

3

Reviews: