Extron DTP HD DA 4K Series • SIS Configuration and Control
11
number, and
60-
xxxx
-01
is the catalog part number.
This is followed by a
Password
prompt if a password has been set.
NOTE:
The factory configured passwords for all accounts on this device have been set
to the device serial number. Passwords are case sensitive.
Using the Command and Response Table
Command and Response Table for SIS Commands
starts on page 15. Symbols
are used throughout the table to represent variables in the command response fields.
Command and response examples are shown throughout the table. The ASCII to HEX
conversion table (see figure 9) is for use with the command and response table.
Figure 9.
ASCII to Hex Conversion Table
NOTE:
For commands and examples of computer or device responses used in this
guide, the character "
0
" is the number zero and "O" is the capital letter "o".
Symbol Definitions
]
= CR/LF (carriage return with line feed)
|
or
}
= Soft carriage return (no line feed)
•
= Space
E
or W = Escape key
NOTE:
If unit does not support or recognize the entered commands, nothing happens
and no response is issued.
X!
=
Output selection
0-4
or loop out to
4
(DTP HD DA4 models)
0-8
or loop out to
8
(DTP HD DA8 models)
X@
=
Status
0
= disabled/off/undetected
1
= enabled/on/detected
X#
=
Video color bit depth
0
= Auto (based on EDID of sink, default)
1
= Force 8-bit
X$
=
EDID memory location
See the
DTP HD DA 4K Series EDID Memory
X%
=
EDID data as 256
bytes of hex data (text
representation)
X^
=
Native resolution and refresh
rate (translated from hex)
Example: 1600x1200 @ 60 Hz
Using the Command and Response Table
9
Summary of Contents for DTP HD DA 4K Series
Page 2: ...Safety Instructions ...
Page 6: ......