26 Jan., 2006

18 AWG 

(19/30) 

0.048" 

1.22 mm, 

Bare Cu 

6.2 ohms/ 

1k ft 

20.3 ohms/ 

1 km 

22 AWG 

(7/30) 

0.030" 

0.76 mm, 

Bare Cu 

14.7 ohms/ 

1k ft 

48.2 ohms/ 

1 km 

18 AWG 

(19/30) 

0.048" 

1.22 mm, 

Bare Cu 

6.2 ohms/ 

1k ft 

20.3 ohms/ 

1 km 

22 AWG 

(7/30) 

0.030" 

0.76 mm, 

Bare Cu 

14.7 ohms/ 

1k ft 

48.2 ohms/ 

1 km 

Alum. Foil 

(100%)

Tinned Cu 

Serve (95%)

12.2 ohms/

1k ft,

40.0 ohms/

1 km

Alum. Foil and 

Tinned Cu 

Braid (85%)

Alum./

Polyester Tape 

with 24 AWG

Tinned Cu 

Drain Wire 

Under Tape 

(100%)

26 ohms/

1k ft

85.3 ohms/

1 km

Alum. Foil 

(100%)

Tinned Cu 

Serve (95%)

12.2 ohms/

1k ft,

40.0 ohms/

1 km

Alum./

Polyester Tape 

with 24 AWG

Tinned Cu 

Drain Wire 

Under Tape 

(100%)

26 ohms/

1k ft

85.3 ohms/

1 km

22-148-02 (500') 

22-148-03 (1000') 
CTL 

insulated 
conduct-

ors 

insulated 
conduct-

ors 

insulated 
conduct-

ors 

insulated 
conduct-

ors 

0.065  1.65 

0.068 

90 

78 

17.3 

90 

78 

17.3 

56.8 

56.8 

1.73 

0.065  1.65 

0.068  1.73 

500 

1000

152.4

304.8

Single:

red, black

500 152.4

1000 304.8

NEC CL2

CM

UL 1581

CSA FT-4

75 °C

Overall 

cable 

Overall 

cable 

21

44

9.5

20.0

22-119-02 (500') 

22-119-03 (1000') 
CTLP 

22

9.9

46

20.7

Single: 

white, violet 

Shielded Pair: 

0.140      3.56 

Single: 

white, violet 

Shielded Pair: 

0.140      3.56 

Overall: 

0.230      5.84 

gray 

Single:

red, black

Overall: 

0.207      5.26 

blue 

NEC CL2P 

CMP 

UL 910 

CSA FT-6 

60 °C 

Overall Cable: 

Alum./ 

Polyester Foil 

with 24 AWG 

Tinned Cu 

Drain Wire 

(100%)

15 ohms/

1k ft,

49 ohms/

1 km

24 AWG

(7/32)

0.024"

0.61 mm,

Tinned Cu

24 ohms/

1k ft,

79 ohms

1 km

24

22-195-03 (1000')
CTL24LC-2P

shielded 

twisted 

pairs

25

1000 304.8

0.050

1.3

11.3

Single:

red, black, 

green, white

Overall:

0.210      5.33

blue

NEC CMP

UL 910

60 °C

conductor-

conductor

conductor-

conductor,

connected to 

shield

16

52

30

98

68%

Specifications — CTL Cable

Specifications — CTL Cable

Part No. (length) 
Model 

Description 

dB/

100 m

MHz

Nominal

Capacitance

dB/

100 ft

Nominal

Attenuation

Nom.

Vel.

of 

Prop.

Shipping 
Weights 

Standard 

Lengths 

Conductor 
(stranding) 

Diameter 

Nom. DCR 

Shielding
Materials

(% coverage)

Nom. DCR

Nom.

Imp.

(ohms)

No. 

of 

Cond. 

Ft. 

Nominal

OD

Inch

mm

Nominal 

Core OD 

Inch  mm 

pF/ft pF/m

Lbs.  kg 

Composite Cable:  (2) 18 AWG Insulated Conductors • (2) 22 AWG Insulated Conductors with Shield 

Nonplenum Cable 

• Gas Injected Foamed Polyolefin Insulation • PVC Inner Jackets • Gray PVC Outer Jacket 

Plenum Cable 

• Gas-injected Foamed FEP Insulation • PVC and FEP Inner Jackets • Blue Flame-retardant PVC Outer Jacket 

UL NEC/ 

C(UL) CEC 

UL AWM 

Temp. 