CTL208CM Control Panel Module • Serial Communications

CTL208CM Control Panel Module • Serial Communications

Serial Communications, cont’d

Control panel module responses

When a command is valid, the module performs the command
and sends the following response:

[R0 {address} {echo of the command sent}]

When a command is invalid, either because the command is not
recognized or contains invalid parameters, the module sends
the following response:

[R1 {address} {echo of the command sent}]

Using the command/response table

The command/response table begins on page 4-13.  Upper or
lower case letters are acceptable in the command field.  The
table below shows the hexadecimal equivalent of each ASCII
command.

ASCII to HEX  Conversion Table

Space

Symbols, defined starting on page 4-11, are used throughout the
table to represent variables in the command/response fields.
Command and response examples are shown throughout the
table.

Symbols

 =

Line feed

X1

 =

Address number

00 - 98 (00 addresses all units but individual units do
not respond, 97 is the factory-installed default).

The very first command that you send to the control panel module
must be the connect, [CC

X1

], command, where 

X1

 is the module’s

address.  The control panel module 

will not accept

 other

commands or respond until it has been addressed.

The very last command that you send to the control panel module
should be the connect, [CC

X1

], command, where 

X1

 is a different

address.  This prevents the control panel module from accepting
and responding to commands for other devices.

X2

 =

Button number and string (primary or secondary) (figure 4-8)

Buttons 1 and 5 are closest to the top of the CTL208.  Orient the
CTL208 so that the text on the rear of the unit is right-side up to
determine the top of the module.

4-10

4-11

X3

 =

ASCII button code Up to 128 alphanumeric characters.

If you need to use the bracket delimiters in a stored
ASCII command, you need to use the insert
brackets feature.  Under this feature, one character
replaces the left bracket ( [ ) and another character
replaces the right bracket ( ] ).  The default values
are a single quote mark ( ‘ ) in place of the left
bracket and a double quote ( “ ) in place of the right
bracket.  The CTL208 replaces the characters with
the bracket delimiters in the stored ASCII or hex
command string.

X4

 =

Bracket position

1 = left bracket, 2 = right bracket.

Figure 4-8 — Button numbers

5

6

7

8

1

Button

number

Button

number

2

3

4

X2

s must be 2-digit numbers.

X2

# Button/string

X2

# Button/string

01 = 1/primary

11 = 1/secondary

02 = 2/primary

12 = 2/secondary

03 = 3/primary

13 = 3/secondary

04 = 4/primary

14 = 4/secondary

05 = 5/primary

15 = 5/secondary

06 = 6/primary

16 = 6/secondary

07 = 7/primary

17 = 7/secondary

08 = 8/primary

18 = 8/secondary

im Vertrieb von

            CAMBOARD Electronics

www.camboard.de

Tel. 07131 911201
Fax 07131 911203

[email protected]

Summary of Contents for Control Panel CTL208CM

Page 1: ...PM Industrial Building Singapore 368363 65 6383 4400 Fax 65 6383 4664 Extron Electronics Japan Daisan DMJ Building 6F 3 9 1 Kudan Minami Chiyoda ku Tokyo 102 0074 Japan 81 3 3511 7655 Fax 81 3 3511 7656 www extron com 2003 Extron Electronics All rights reserved 8 Button Control Panel Module with Serial Control Output 68 836 01 Rev A Printed in the USA 07 03 CTL208CM im Vertrieb von CAMBOARD Electr...

Page 2: ...nur von qualifiziertem Servicepersonal durchgeführt werden Die internen Komponenten des Gerätes sind wartungsfrei Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall dieses Gerät selbst öffnen da beim Entfernen der Abdeckungen die Gefahr eines elektrischen Schlags und oder andere Gefahren bestehen Schlitze und Öffnungen Wenn das Gerät Schlitze oder Löcher im Gehäuse aufweist die...

Page 3: ...module s rear panel DIP switches Step 5 Connect a serial cable between the control panel module and a computer Step 6 Connect the external power supply to the control panel module Step 7 Program the control panel module s buttons as desired using either the Extron ICS100 control software or the Extron ASCII character command set Step 8 If necessary set the control panel module s serial control set...

Page 4: ...gramming the CTL208 4 13 Table of Contents Step 10 If the rear of the control panel module will be inaccessible when the installation is complete the module should be powered up and its operation should be tested before the final installation Apply or connect power to all devices in the system Step 11 Test the system Ensure that the controlled device responds as desired to the control panel module...

Page 5: ...ademarks mentioned in this manual are the properties of their respective owners Appendix Reference Information A 1 Specifications A 2 Parts List A 3 Included parts A 3 Mini AAP mounting options A 3 Wall mounting solutions A 3 Architectural solutions A 4 Table solutions A 4 Wall mounting hardware A 4 im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camb...

Page 6: ...I or hex string programmed to a button when you press that button The module sends the secondary string when you press the button a second time Button grouping Buttons that are in toggle mode can also be assigned to a group When one button is selected the control panel module deselects all other buttons in the group Button timeout Buttons that are in toggle mode can be further set to automatically...

Page 7: ...odule 2 Chapter Two Installation Installation Overview UL Requirements for Wall Box Installation Wall Mounting Site Preparation DeviceConfiguration Wall Mounting Rear Panel Setup 1 4 im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de ...

Page 8: ...e mini AAP mounting option as necessary See Wall mounting in this chapter for details about wall mounting the panel 18 Restore power to all devices 2 3 Installation Overview CAUTION Installation and service must be performed by authorized personnel only UL Listed electrical boxes are recommended See UL Requirements for Wall Box Installation in this chapter 1 If desired order a custom engraved fron...

Page 9: ...shield can be cut back to the point where the cable exits the cable clamp Both braided and foil shields should be connected to an equipment ground at the other end of the cable 2 5 2 4 UL Requirements for Wall Box Installation The following Underwriters Laboratories UL requirements pertain to the installation of the CTL208CM into a wall or furniture figure 2 1 2 5 Installation Cable Conduit Extron...

Page 10: ...rt the wall box into the opening and attach it to the wall stud or furniture with nails or screws leaving the front edge flush with the outer wall or furniture surface figure 2 3 The illustration applies to both two gang and four gang wall boxes Wall opening flush with edge of box Installation Cable Cable Clamp Screws or Nails Wall Stud Figure 2 3 Attaching a wall box to a stud If attaching the wa...

Page 11: ... 1 SERIAL MODE 0 RS232 2 3 TERMINATION 1 RS485 RS422 1 120 OHMS 0 OPEN END UNIT 4 RESERVED 5 FACTORY RESET 0 NORMAL SPARE 6 1 3 2 Figure 2 7 Rear panel view 2 9 2 8 Wall Mounting The physical orientation of the control panel module is important when you are programming and operating the buttons Buttons 1 and 5 figure 2 5 are on top when the CTL208 is right side up Orient the CTL208 so that the tex...

Page 12: ...tch Function On 1 On 1 1 Serial mode RS 485 position RS 422 position 2 Rx termination On 1 or Off 0 On 1 or Off 0 On 1 if full duplex or Off 0 if half duplex 3 Tx termination Off 0 Off 0 Off 0 Off 0 RS 232 position If the CTL is the last unit in a daisy chain The default settings for all switches for an RS 232 connection is off 0 DIP switch 3 should be turned on for an RS 485 full duplex connectio...

Page 13: ...on Installation cont d CTL208CM Control Panel Module 3 Chapter Three Operation ButtonModes Send Programmed Commands Factory Reset 2 12 im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de ...

Page 14: ...er set to automatically toggle off after a user defined period of time up to 255 minutes Timeouts cannot be assigned to buttons that are set to operate in groups Send Programmed Commands 5 6 7 8 1 Button number Button number 2 3 4 Figure 3 1 Power connector wiring The actions that occur when you push a programmed button vary depending on how the button is programmed Single mode Push the button to ...

Page 15: ...curs on the full minute Thus the timeout can occur up to 59 seconds earlier than the number of minutes programmed Over the length of the average timeout setting this early timeout is considered of no consequence Factory Reset With power removed set rear panel DIP switch 5 to on up Reapply power Set switch 5 back to off down The DIP switch factory reset performs the following functions Resets the c...

Page 16: ...he Browse button An open file window appears 3 Navigate to the drive or folder that contains the software 4 Double click the setup icon 5 Click Ok in the Run window 6 Click Ok in the InlineControl Setup window 7 Click the icon button in the next InlineControl Setup to install the software in the default Extron directory in the Program group If you want to specify a different directory click on the...

Page 17: ...nel module can also take commands after receiving a broadcast address of 00 but it will not send responses Broadcast addressing is for multiple units on an RS 485 serial line in half duplex mode After you are finished sending commands to the control panel module always end the session by selecting a different address than the one assigned to the CTL208 This prevents the module from responding to c...

Page 18: ...ss the button the CTL sends the hex value 6 In the Button Codes window figure 4 7 enter the desired primary code in the Code 1 window Codes that are intended to be hex codes must be in pairs Use a leading 0 if necessary Letters must be upper case Many common keyboard key codes which are often required for ASCII or hex control of another device are available in the selection buttons on the bottom o...

Page 19: ... module s serial port is factory configured to 9600 baud no parity no flow control half duplex mode If you change the serial protocols communications between the computer and the control panel module are lost until the computer is updated to match the new control panel module settings The communications protocols of the control panel module should match the protocols of the device to be controlled...

Page 20: ...y last command that you send to the control panel module should be the connect CC X1 command where X1 is a different address This prevents the control panel module from accepting and responding to commands for other devices X2 Button number and string primary or secondary figure 4 8 Buttons 1 and 5 are closest to the top of the CTL208 Orient the CTL208 so that the text on the rear of the unit is r...

Page 21: ...ature Any character other than 0 is the character that will be replaced by a bracket or when the X3 code is saved to a CTL208 button X6 Hex button code Similar to the ASCII button code X3 with the addition of an ASCII to hex conversion before the value is stored For example if you send the ASCII value 0F the CTL converts it to the hex value 0F When you press the button the CTL sends 0F hex Entries...

Page 22: ...t to default CPp R0 X1 CPp Reset the control panel module to its default serial port settings 9600 baud no parity Xoff and half duplex mode View serial port parameters CPp R0 X1 CPp X11 X12 X13 X14 Button code programming continued View a button s hex code PCHp X2 R0 X1 PCHp X2 X6 Reset button code ASCII or hex PCLp X2 R0 X1 PCLp X2 Clear any codes assigned to a button The CTL will not send any co...

Page 23: ...l lockout FP R0 X1 FP Toggle front panel status enabled to disabled or disabled to enabled View front panel lockout FP R0 X1 FP X15 Enable disable responses Enable serial responses RES1 R0 X1 RES1 Control panel module sends responds to serial port commands Disable serial responses RES0 none Control panel module does not send responses to serial port commands Control panel module reset Reset contro...

Page 24: ...rence Information A 2 Specifications Control remote Serial control port 1 RS 232 RS 422 or RS 485 5 pole captive screw connector Baud rate and protocol 1200 2400 4800 9600 default 19200 or 38400 baud 8 bit 1 stop bit no parity default even parity or odd parity half default fullduplex Pin configurations RS 232 3 TX 5 RX 1 Gnd RS 422 RS 485 3 TX 2 TX 5 RX 4 RX 1 GND Program control Extron s ICS100 c...

Page 25: ...CIA112 2 CIA112 black without cable guards CIA112 3 CIA112 Inline white without cable guards CIA112 4 RGB 478 Mxi black 60 592 02 RGB 48 Mxi white 60 592 03 Table solutions Description Part number CPM208 1 Mini AAP bay 60 589 13 CPM212 1 Tabletop mini AAP bay black 60 590 11 CPM212 2 Tabletop mini AAP bay white 60 590 21 Wall mounting harware Description Part number One gang J box 2 5 deep 980130 ...

Reviews: