Extron electronics CIA111 User Manual Download Page 11

CIA111 and CIA114 • Installation and Operation

CIA111 and CIA114 • Installation and Operation

Installation and Operation, cont’d

Mounting the CIA114F5

The CIA114F5 is designed to fit into a Steel City 665 floor box.
The installation must conform to national and local electrical
codes and to the interface’s size requirements.

CAUTION

The interface must be installed into an
Underwriters Laboratories (UL) approved Steel
City electrical floor box.  The floor box is not
included with the interface; the installer is
responsible for obtaining and installing the box.

Preparing the site and cables

1.

Choose a location that allows cable runs without
interference.  Allow enough depth for both the floor box
and the cables.  You need to run the conduit (if required by
local code) and cables under the floor before installing the
interface.

2.

Install the floor box in accordance with the documentation
that accompanied the box.

3

.

Feed cables through the floor box punch-out holes, and
secure them with cable clamps to provide strain relief.

4.

Exposed cable shields (braids or foil) are potential sources
of short circuits.  Trim back and/or insulate shields with
heat shrink.

CAUTION

To prevent short circuits, the outer foil shield can be
cut back to the point where the cable exits the cable
clamp.  Both braided and foil shields should be
connected to an equipment ground at the other end
of the cable.

5

.

Set the DIP switches and cable and test the interface before
securing the device into the floor box.  The switches and
cables will be inaccessible after installation

.

Mounting the interface to the floor box

1.

Disconnect the power supply to remove power from the
interface.

2

.

If installed, remove the floor box’s top panel and trim
frame.

3.

Place the interface through the opening in the floor and
into the floor box.  Take care not to damage the cables,
which lay behind the interface in the bottom of the box.

4.

Attach the interface to the floor box by hooking the two
locking tabs on the bottom of the interface’s faceplate into
the slots on the bottom of the box.  Secure the faceplate to
the top of the floor box with the included 1/2 inch Phillips
screws.

5

.

Install the floor box’s top panel and trim frame.

6.

Reconnect the power supply.

Figure 2-9 — CIA114F5 installed

2-12

2-13

im Vertrieb von

            CAMBOARD Electronics

www.camboard.de

Tel. 07131 911201
Fax 07131 911203

[email protected]

Summary of Contents for CIA111

Page 1: ...ngapore 368363 65 6383 4400 Fax 65 6383 4664 Extron Electronics Japan Daisan DMJ Building 6F 3 9 1 Kudan Minami Chiyoda ku Tokyo 102 0074 Japan 81 3 3511 7655 Fax 81 3 3511 7656 www extron com 2004 Ex...

Page 2: ...iziertem Servicepersonal durchgef hrt werden Die internen Komponenten des Ger tes sind wartungsfrei Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall dieses Ger t selbst ffnen da...

Page 3: ...7 Mounting the Interfaces 2 8 Mounting the CIA111 or CIA114 2 8 UL Requirements 2 8 Preparing the site and installing the wall box 2 8 Mounting optional MAAP devices CIA111 only 2 10 Mounting the int...

Page 4: ...er One Introduction About this Manual About the CIA111 CIA114 and CIA114F5 Features 68 809 01 Rev A Printed in USA 09 04 All trademarks mentioned in this manual are the properties of their respective...

Page 5: ...feature image shift and monitor emulation adjustments from the front panel Sharpness and output sync can be adjusted using rear panel controls Each interface accepts one computer video input 15 pin H...

Page 6: ...rom all the devices 8 Mount the interface into the wall or floor box refer to the section later in this chapter that addresses your specific requirements If optional MAAP devices are being installed C...

Page 7: ...nt Applying power with incorrect voltage polarity could damage the power supply and the CIA Identify the power cord positive lead by the red heat shrink wrapping around it To verify the polarity befor...

Page 8: ...cture appears check the computer s user s guide or contact Extron to determine if special commands are required to output video to the external video port Also many laptops screens shut off after the...

Page 9: ...ox and the cables You may need to install the cables into the wall furniture or conduits before installing the interface 2 Use the appropriate template in Appendix A as a guide to measure and mark the...

Page 10: ...AG E SH IFT NO MO NITO R CO MP UT ER INPU T Extron CIA111 Extron MAAP Figure 2 7 Mounting the optional MAAP device standard MAAP device shown 2 Follow steps 3 through 9 in the Installation Overview s...

Page 11: ...s of short circuits Trim back and or insulate shields with heat shrink CAUTION To prevent short circuits the outer foil shield can be cut back to the point where the cable exits the cable clamp Both b...

Page 12: ...n cont d CIA111 and CIA114 Computer Video Interface A Appendix A Reference Information Specifications Included Parts Accessories Cables and Adapters Templates 2 14 im Vertrieb von CAMBOARD Electronics...

Page 13: ...ositive or negative follows input Audio Gain Unbalanced output 6 dB balanced output 6 dB Frequency response 20 Hz to 20 kHz 0 4 dB THD Noise 0 03 1 kHz at nominal level 0 1 20 kHz at nominal level S N...

Page 14: ...lack white 60 597 12 13 CIA114F5 60 597 32 IEC power cord 9VDC 1A external power supply 28 070 01 632 1 2 inch Phillips screws 2 Tweeker small screwdriver CIA111 and CIA114 User s Manual A 4 Enclosure...

Page 15: ...th audio 70 157 03 Templates Use the appropriate template on the next two pages as a guide to measure and mark the hole in the wall or furniture for installing the wall box for mounting a CIA111 or CI...

Page 16: ...on s CIA114 TEMPLATE IS NOT FULL SIZE To install CIA114 directly into furniture cut along this line Top Panel 2 1 5 3 cm 3 0 7 6 cm SURFACE CUT OUT AREA FOR FURNITURE MOUNT 2 75 7 0 cm Location of CIA...