3. Slide the transceiver from the module slot.

4. If the transceiver does not slide easily from the module slot, use a gentle side-to-side rocking

motion while firmly pulling the transceiver from the slot.

5. Attach a dust cover over the fiber-optic bores and store the transceiver in a safe place until

you need it.

Important:

Discard transceivers in accordance with the proper laws and regulations.

AC power supply specifications

This section describes the regulatory AC power specifications for the VSP 4000 4450GSX series
switches.

The following table describes the regulatory AC power specifications for the VSP 4450GSX-PWR+
switch and its TAA compliant version. The regulatory AC power specifications are based on the
maximum rated capacity of the power supplies and are not based on typical power consumption,
which is lower.

Table 1: AC power specifications

4450GSX-PWR+

Input Current:

12A/6A

Input Voltage (rms):

100 to 240VAC at 50 to 60 Hz

Power Consumption:

248 W maximum

Thermal Rating:

508 BTU/Hr maximum

Inrush Current:

70 A maximum

Turn on Condition:

1 second maximum after application of AC power

Important:

12 V output rise time, from 10 to 90 per cent, must be the maximum of 50 ms and monotonic under all
defined input and output conditions.

November 2017

Installation Job Aid for VSP 4450GSX Series

7

Summary of Contents for VSP 4450GSX Series

Page 1: ...SD ESD notices provide information about how to avoid discharge of static electricity and subsequent damage to products Caution Caution notices provide information about how to avoid possible service...

Page 2: ...ion When mounting this device in a rack do not stack units directly on top of one another in the rack Each unit must be secured to the rack with appropriate mounting brackets Mounting brackets are not...

Page 3: ...nlight No nearby sources of severe electromagnetic noise No excessive dust Adequate power source within six feet one 15 Amp circuit required for each power supply At least 2 inches 5 08 cm on all side...

Page 4: ...To install a VSP 4000 on a table or shelf perform this procedure 1 Attach the included rubber footpads on the bottom of the switch at the locations indicated 2 Set the switch on a table or shelf as i...

Page 5: ...ndard 19 inch 48 2 centimeter equipment rack The rack is bolted to the floor and braced if necessary The rack is grounded to the same grounding electrode used by the power service in the area The grou...

Page 6: ...transceiver into the proper module on the switch Apply a light pressure to the transceiver until it clicks and locks into position in the module 5 Remove the dust cover from the transceiver optical bo...

Page 7: ...escribes the regulatory AC power specifications for the VSP 4450GSX PWR switch and its TAA compliant version The regulatory AC power specifications are based on the maximum rated capacity of the power...

Page 8: ...wer specifications The VSP 4000 4450GSX PWR including the TAA compliant version supports dual 54V 1000W Power over Ethernet Plus PoE AC power supplies Important Ensure that you use only 1000W power su...

Page 9: ...pecifications for this switch Table 3 DC power supply specifications Description DC DC 12V 300 W Output power 300 W Input voltage 48 V DC Input current 10 A Output voltage 12 V DC Output current 25 A...

Page 10: ...ower supply is fully seated in the slot Secure the power supply with the two thumb screws Note The switch chassis can prevent an incorrect installation of a power supply If you insert a power supply u...

Page 11: ...he cord 100 or 120VAC 50 60 Hz Single phase United Kingdom BS1363 male plug with fuse Harmonized cord 240VAC 50 Hz Single phase Australia AS3112 1981 male plug 240VAC 50 Hz Single phase Danger Using p...

Page 12: ...Figure 3 DC power cable Figure 4 DC power cord housing unit with terminals November 2017 Installation Job Aid for VSP 4450GSX Series 12...

Reviews: