Table 38: Power Specifications (DC Power Supplies) (continued)
Maximum wire size
14 AWG (1.5 mm2 copper stranded).
DC Output
+12.2VDC, 61.5A; +12Vaux, 2.5A
Power (W)
750 W
Table 39: Environmental Specifications (All Power Supply Units)
Operating temperature
0°C to 55°C (normal operation)
Storage temperature
-40°C to 70°C
Operating humidity
20% to 90% relative humidity, non-condensing
Operational shock
30 m/s
2
(3 G)
Power Cord Requirements for AC-Powered Switches and AC
Power Supplies
An AC power cord is not included with the AC power supply.
Power cords used with AC-powered switches or AC power supplies must meet the following
requirements:
•
The power cord must be agency-certified for the country of use.
•
The power cord must have an IEC320-C13 connector for connection to the switch or power supply.
•
The power cord must have an appropriately rated and approved wall plug applicable to the country
of installation.
•
For cords up to 6 feet (2 m) long, the wire size must be 18 AWG (.75 mm
2
) minimum; over 6 feet, the
minimum wire size is 16 AWG (1.0 mm
2
).
For details about obtaining AC power cords for use in your country, refer to
www.extremenetworks.com/product/powercords/