RPS-500p Connector
See
and
on page 77 for pin locations and function.
Note
The following information is for troubleshooting purposes only. For proper operation, use only
the 1 meter RPS cable supplied with the RPS-500p. This cable is specially designed for this
application and meets all necessary regulatory and safety standards. The use of non-
approved cables will void your warranty.
Figure 48: RPS-500p Connector Pin Locations
Table 31: RPS-500p Connector Pins
Pin
Function
Pin
Function
1
- 55 V return
8
Ground
2
- 55 VDC
9
No connection
3
12 VDC output
10
RPS present
4
12 VDC output
11
Status 1 Status
5
12 VDC output
12
Status 2
6
12 VDC output
13
Power good
7
Ground
14
Ground
Power Cord Requirements for AC-Powered Switches and AC
Power Supplies
An AC power cord is not included with the AC power supply.
Power cords used with AC-powered switches or with Summit AC power supplies must meet the
following requirements:
•
The power cord must be agency-certified for the country of use.
•
The power cord must have an IEC320-C13 connector for connection to the switch or power supply.
Technical Specifications
ExtremeSwitching 210 and 220 Series Switches: Hardware Installation Guide
77