Fan operating noise:
–
Based on ISO 7779
–
< 60 dB-A
Safety agency approvals
•
CAN/CSA-22.2 No.60950-1-07/UL 60950-1-Second Edition
•
EN 60825-1 Safety of Laser Products - Part 1: Equipment Classification, Requirements and User’s Guide
•
EN 60825-2 Safety of Laser Products - Part 2: Safety of Optical Fibre Communications Systems
•
CE EN60950-1: 2006
•
TUV EN60950-1: 2006
•
IEC EN60950-1:2005
Electromagnetic approvals
•
FCC Part 15, Subpart B (Class A)
•
EN 55022 (CE mark) (Class A)
•
CISPR-22 (class A)
•
ICES-003 (Canada) (Class A)
•
AS/NZ 55022 (Australia) (Class A)
•
VCCI (Japan) (Class A)
•
EN 61000-3-2
•
EN 61000-3-3
•
EN 61000-6-3
Port specifications
This section provides pin assignments for the following ports:
•
Device’s console port (serial connector)
•
Device’s management port (RJ-45 unshielded twisted pair (UTP) connector)
DANGER
The intra-building port or ports of the equipment or subassembly is suitable for connection to intra-building or unexposed
wiring or cabling only. The intra-building port or ports of the equipment or subassembly MUST NOT be metallically
connected to interfaces that connect to the outside plant (OSP) or its wiring. These interfaces are designed for use as
intra-building interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE, Issue 5) and require isolation from
the exposed OSP cabling. The addition of Primary Protectors is not sufficient protection in order to connect these
interfaces metallically to OSP wiring.
Safety agency approvals
ExtremeSwitching CES 2000 Series and ExtremeRouting CER 2000 Series Hardware Installation Guide
72
9035631-01