• Avoid contact between equipment and clothing. The wrist or ankle strap protects only the
equipment from ESD voltages on the body; ESD voltages on clothing can still cause
damage.
• Avoid touching any connector pins.
• Do not remove the wrist or ankle strap until the installation is complete.
Preventing electrostatic damage in new cable installations
With new cable installations, you are recommended to use an ESD discharge cable to reduce the
potential for damage from static, that can build up in cables. The following figure illustrates an ESD
cable.
Figure 3: Job aid
To install the ESD discharge cable, perform this procedure.
1. Connect the ground lug on the ESD discharge cable to a safe and suitable earth ground.
2. Connect all RJ45 cable connectors to the female RJ45 connector of the ESD discharge
cable for at least 5 seconds, and then connect each RJ45 cable connector to the switch.
3. Leave cables connected to the networking equipment. After you connect cables to
networking equipment, the cables do not build up charge.
Technical specifications
The following table provides the technical specifications for the individual switches in this series.
Ensure that the area where you install the switch and where it operates meets these requirements.
Installing the VSP 4000 4850GTS Series
August 2018
Installing Virtual Services Platform 4850GTS Series
20