Extreme Networks AP60C Hardware User'S Manual Download Page 2

This icon indicates a general caution. Failure to comply with a caution notification can result in damage to equipment.

This icon indicates an electrical caution. Failure to comply with an electrical notification can result in serious injury or
death, and extensive damage to equipment.

This icon indicates a laser caution. Failure to comply with a laser caution can result in serious injury.

The following table lists the safety precautions you should follow when installing your AP460C devices.

Extreme Networks devices must be installed by a professional installer who is certified to install these types of devices
and to ensure that they are properly grounded and meet applicable local and national electrical codes.

These devices are intended for indoor use only.

Warning

: This is a Class A product. In a domestic environment this product may cause radio interference in which case

the user may be required to take adequate measures.

Do not install the device in an environment where the operating ambient temperature might exceed the recom-
mended ranges.

For products available in the USA/Canada market, for the 2.4 GHz band, only channels 1-11 can be operated. Selec-
tion of other channels is not possible.

Changes or modifications made to this device that are not expressly approved by the party responsible for com-
pliance could void the user's authority to operate the equipment.

Use only attachments and accessories specified by Extreme Networks.

These devices are not intended for use by persons (including children) with reduced physical, sensory, or mental cap-
abilities, or with lack of experience of knowledge unless they are given supervision or instruction concerning use of the
devices by a person who is responsible for their safety. Children should be supervised to ensure that they do not play
with the devices.

Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. ESD damage occurs when elec-
tronic components are improperly handled and can result in complete or intermittent failures. Be sure to follow ESD-pre-
vention procedures when handling electronic components and equipment.

During operation, the surfaces of the AP460C device can become hot. Use caution when handling.

To

 

meet

 

federal

 

radiation

 

exposure

 

requirements,

 

these

 

devices

 

should

 

be

 

installed

 

at

 

a minimum

 

distance

 

of

 

1

2

"

 

(

30 

cm)

 

from

 

people

 

or

 

animals.

Install the AP

The following sections describe how to mount your AP in an outdoor location on a pole or flat surface.

Shipping Carton Contents

The AP460C shipping cartons contain the following items:

l

AP460C chassis with two installed M20 cable gland assemblies and plugs, two installed M25 seal caps.

l

Hardware bag containing grounding hardware (M4 screw, split washer, and lock washer)

l

Read Me card.

AP60C Hardware Guide

2

AP460C Hardware Guide

2

To meet Canadian radiation exposure requirements, these devices should be installed at aminimum distance of 

14" (35 cm) from people or animals.

Summary of Contents for AP60C

Page 1: ...ich the AP will be deployed to meet regulatory requirements and for optimal wireless operation To do this follow these steps The country code selection is for World models only and is not available to...

Page 2: ...e equipment Use only attachments and accessories specified by Extreme Networks These devices are not intended for use by persons including children with reduced physical sensory or mental cap abilitie...

Page 3: ...warnings For best performance deploy AP460C devices in relatively open areas at least 100 30 5 m apart from each other Install the Device on a Vertical or Horizontal Pole Use the following steps to i...

Page 4: ...o provide four mounting bolts or screws and wall mount anchors that are appropriate for the wall type where youare installing the device 1 Insert the four M5 bolts that come in the bracket accessory k...

Page 5: ...or horizontal mounts be sure that the ports are facing earth to reduce the chance of water entering the chassis As an added security measure youcan thread a safety strap through one of the cable strap...

Page 6: ...sal power cord with US plug l AH ACC PW CBL UK 6 universal power cord with UK plug l AH ACC PW CBL EU 6 universal power cord with EU plug l AH ACC PW CBL AU 6 universal power cord with AU plug l AH AC...

Page 7: ...ssover standard Cat2 Cat5 Cat5e or Cat6 Ethernet cables automatically The AP receives power through an Ethernet connection to the ETH0 port from PSE power sourcing equipment that is compatible with th...

Page 8: ...factory default settings To prevent the reset button from resetting the configuration enter this command no reset button reset config enable When this command is enabled pressing the button for 5 seco...

Page 9: ...5 850 GHz operating frequency l 802 11n modulation l Rates MCS0 MCS7 6 5 MBps 600Mbps l 1x1 2x2 4x4 MIMO radio l HT20 HT40 support l A MPDU and A MSDU frame aggregation 802 11ac l 5 150 5 350 5 470 5...

Page 10: ...dBm 11g 54 Mbps 15 dBm 48 Mbps 16 dBm 36 Mbps 17 dBm 6 Mbps 18 dBm HE20 MCS 0 1 2 18 dBm MCS 3 17 dBm MCS 4 5 16 dBm MCS 6 7 15 dBm MCS 8 9 14 dBm MCS 10 11 12 dBm 2 4 G Sensitivity 11b 1 Mbps 99 dB...

Page 11: ...17 dBm MCS 9 16 dBm MCS 10 15 dBm MCS 11 14 dBm HE80 MCS 0 1 2 19 dBm MCS 3 4 5 18 dBm MCS 6 7 8 17 dBm MCS 9 16 dBm MCS 10 15 dBm MCS 11 14 dBm HE160 MCS 0 1 2 19 dBm MCS 3 4 5 18 dBm MCS 6 7 8 17 dB...

Page 12: ...MCS 4 80 db MCS 5 76 db MCS 6 74 db MCS 7 73 db MCS 8 69 db MCS 9 67 db MCS 10 63 db MCS 11 60 db HE80 MCS 0 88 db MCS 1 85 db MCS 2 83 db MCS 3 80 db MCS 4 77 db MCS 5 73 db MCS 6 71 db MCS 7 69 db...

Page 13: ...at compliant PoE l Eth1 Ethernet port autosensing 10 100 1000Base T TXMbps Antennas l 3 integrated single band 5 1 5 8 GHz omnidirectional antennas l 4 integrated dual band 2 4 1 5 GHz and 5 1 5 8 GHz...

Page 14: ...AP60C Hardware Guide 15 AP460C Hardware Guide 15 Antenna Plots The antenna plots for the AP460C are available below The Ethernet port location is noted on each chart...

Page 15: ...AP60C Hardware Guide 16 AP460C Hardware Guide 16...

Page 16: ...AP60C Hardware Guide 17 AP460C Hardware Guide 17...

Page 17: ...DC 0 45A 19 2W Max PoE without USB IEEE 802 3af 37 42 5VDC Maximum l 54V DC 0 43A 23 3W Max PoE with USB 2 5W IEEE 802 3at only 42 5 57VDC USB 0 5A l 42 5V DC 0 49A 20 8W Max PoE without USB IEEE 802...

Page 18: ...53 EU l English Hereby Extreme Networks declares that this Undefined variable Primary AP640 is in compliance with the essential require ments and other relevant provisions of Directive 2014 53 EU l E...

Page 19: ...5250 5350 5470 5600 5650 5850 MHz l BLE 2402 2480 MHz c Taiwan l l 802 11b g n ac 2 4 GHz band 2412 2462 MHz l l 802 11a n ac ax 5 GHz band 5180 5320 5500 5825 MHz l l BLE 2412 2462 MHz EU Radio Freq...

Page 20: ...5150 5350 MHz EIRP 23 dBm 5470 5850 MHz EIRP 30 dBm 5725 5850 MHz 14 dBm l BLE 2402 2480 MHz EIRP 8 dBm German Deutsch Dieses Produkt unterst tzt die folgenden Funkfrequenzen und Leistungsstufen in de...

Page 21: ...GHz band 2400 2483 MHz EIRP 20 dBm l 802 11a ac n ax 5 GHz band 5150 5350 MHz EIRP 23 dBm 5470 5850 MHz EIRP 30 dBm 5725 5850 MHz 14 dBm l BLE 2402 2480 MHz EIRP 8 dBm Slovenian Slovenija Ta izdelek...

Page 22: ...m nyek teljes t se rdek ben ezeket az eszk z ket legal bb 20 cm t vols gra kell felszerelni az emberek vagy az llatokt l Korl toz sok 5150 5350 MHz csak belt ri haszn latra Italian Italiano Per soddis...

Page 23: ...his equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance of 12 30 cm between the radiat...

Page 24: ...Dclaration d exposition aux radiations Cet quipement est conforme aux limites d exposition aux rayonnements IC tablies pour un environnement non contr l Cet quipement doit tre install et utilis avec u...

Reviews: