SAFETY

Read the following safety instructions before 

attempting to operate this product.

Keep these instructions in a safe place or store 

in the carry case for future reference.

SAVE ALL WARNINGS AND INSTRUCTIONS 

FOR FUTURE REFERENCE.

     WARNING: Read and understand all 

instructions.

 

Use only accessories that are recommended 

for your model.

 Tool service must be performed only by 

qualified  repair  personnel.  Repairs,  service 

or  maintenance  performed  by  unqualified 

personnel will void the warranty. Only approved 

and authorised service technicians can carry 

out warranty repairs.

!

!

 Position the optical level securely on a level 

surface. Damage or serious injury could result 

if the optical level falls.

  

      WARNING: DO NOT DISASSEMBLE 

THE OPTICAL LEVEL. There are no user 

serviceable parts inside. Disassembling the 

optical level will void all warranties on the 

product. Do not modify the product in any way. 

Summary of Contents for 32x

Page 1: ...3 2 x O P T I C A L L E V E L I N S T R U C T I O N M A N U A L...

Page 2: ...2...

Page 3: ...vice must be performed only by qualified repair personnel Repairs service or maintenance performed by unqualified personnel will void the warranty Only approved and authorised service technicians can...

Page 4: ...rry case Extreme 32x with attached lens cap not pictured ITEM CHECKLIST Please ensure the following items are included with your optical level If anything is missing please contact your retailer Plumb...

Page 5: ...AL LEVEL OVERVIEW 5 8 x 11 tripod thread 360 protractor Bubble vial Bubble vial mirror Optical view guide Front lens element Panning screw Panning screw Focusing knob Levelling screw Base plate Carry...

Page 6: ...g the levelling screws USING YOUR OPTICAL LEVEL Point the instrument towards the desired area Use a bright background or hold a white sheet of paper in front of the area Turn the eyepiece until the cr...

Page 7: ...the upper and lower hairs Multiply the figure by 100 to calculate the distance between the instrument and the staff Angle measurement Point the instrument towards the first point Set the protractor ba...

Page 8: ...e vial Take an accurate measurement reading from staff A Example 1 924m Take an accurate measurement reading from staff B Example 1 712m Subtract the measurement of staff B from staff A Example 1 924m...

Page 9: ...by adjusting the levelling screws until level Turn the instrument 90 at a time and check the position of the bubble inside the vial If the bubble moves out of the centre ring a service and calibratio...

Page 10: ...g the measurements and calculations shown in these steps a service and calibration is required COMPENSATOR Place the instrument onto a solid tripod between two staves spaced 30m to 50m apart Level off...

Page 11: ...11 1 712m 1 696m 1 484m 1 924m 0 212m STAFF B STAFF A...

Page 12: ...months if ongoing accurate levelling is required or an impact has occurred The operator should check the accuracy of the instrument before precision levelling is attempted Failure to do so may result...

Page 13: ...r any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major...

Page 14: ...14 To assist you with any queries or technical questions please contact customer support Australia 1300 658 338 New Zealand 0800 367 527 CUSTOMER SUPPORT...

Page 15: ...pecifications Extreme 32x Product code 60163 Warranty 10 Years Accuracy 1mm at 1km double run Compensator range 15 Magnification 32x Minimum focus 1m Objective aperture 36mm Weight kg 1 80 Dimensions...

Page 16: ...www spoton com au...

Reviews: