![Extraflame IRMA PLUS Manual Download Page 14](http://html.mh-extra.com/html/extraflame/irma-plus/irma-plus_manual_2454211014.webp)
85C°
85C°
14
ENGLISH
ADDITIONAl THeRmOsTAT fOR DUCTING mOTOR CONTROl
For models with ducting motor there is also the possibility of thermostatting the motor itself. The connection of an external thermostat will
allow to control the ducting motor independently from stove functioning.
At this point just set the desired temperature on the thermostat; the thermostat will control the functioning of the second motor:
with temperature to be reached (closed contact) the second motor will follow the trend of
the stove.
when the temperature has been reached (open contact), it takes the ducting motor to 1st
speed and will be displayed by the flashing LEd relating to the ducting motor.
The ducting thermostat clamp is fitted with a jumper as standard.
See the example drawing to the side.
Features:
ducting outlet diameter: 2x80 mm
maximum recommended ducting length 2m
it is not possible to thermostat the ducting
possibility to adjust the fan speed in percentage
ReARms
The figures below illustrate the positions of the tank (85°c) rearms. contact the qualified technician if one of the rearms should be triggered,
so as to verify the cause.
Summary of Contents for IRMA PLUS
Page 1: ...MADE IN ITALY design production lcd 004276517 Rev 008 UK pellet stoves USER MANUAL ...
Page 2: ...2 ENGLISH ...
Page 4: ...4 004276809 000 FOGLIO APPLICAZIONE SILICONE ILENIA Silicone ILENIA ENGLISH ...
Page 6: ...6 004276829 000 FOGLIO APPL SIL SIBILLA SIBILLA PLUS Silicone SIBILLA SIBILLA PLUS ENGLISH ...
Page 29: ...A B C E E E F F D F D D 29 ENGLISH ...
Page 37: ...37 ENGLISH ...
Page 38: ...38 ENGLISH ...
Page 39: ...39 ENGLISH ...