EXAMPLES OF CORRECT CONNECTION TO THE CHIMNEY

In the presence of type B gas appliances with intermittent operation not intended for heating, they must have their own aeration and/or 

ventilation opening. 
The air inlets must meet the following requirements:

 

Š

they must be protected with grids, metal mesh, etc., but without reducing the net useful section;

 

Š

they must be made so as to make the maintenance operations possible;

 

Š

positioned so that they cannot be obstructed;

The  clean  and  non-contaminated  air 

fl

ow  can  also  be  obtained  from  a  room  adjacent  to  that  of  installation  (indirect  aeration  and 

ventilation), as long as the 

fl

ow takes place freely through permanent openings communicating with the outside.

The adjacent room cannot be used as a garage, or to store combustible material or for any other activity with a 

fi

re hazard, bathroom, 

bedroom or common room of the building.

FLUE GAS EXHAUST

The heat generator works in depression and is equipped with an outlet fan for 

fl

ue gas extraction. There must be a single exhaust system for 

the generator. Using a 

fl

ue that is shared with other devices is not allowed.

The components of the 

fl

ue gas exhaust system must be chosen in relation to the type of appliance to be installed in compliance with:

 

Š

UNI/ TS 11278 in the event of metal chimneys, with particular attention to that stated in the speci

fi

cation; 

 

Š

UNI EN 13063-1 and UNI EN 13063-2, UNI EN 1457, UNI EN 1806 in the event of non-metallic chimneys.

 

Š

The length of the horizontal section must be minimal and, in any case, no longer than 3 metres, with a minimum upward slope of 3%

 

Š

There must not be more than 4 direction changes including the one due to the use of the "T" element.

 

Š

A “T” 

fi

tting with a condensation collection cap must be provided at the base of the vertical section.

 

Š

If the exhaust is not inserted in an existing 

fl

ue, a vertical section with a windproof end piece is required (UNI 10683).

 

Š

The vertical duct can be inside or outside the building. If the smoke duct is inserted in an existing 

fl

ue, it must be certi

fi

ed for solid fuel.

 

Š

If the smoke duct is outside the building, it must always be insulated.

 

Š

The smoke ducts must have at least one airtight inlet for 

fl

ue gas sampling.

 

Š

All the sections of the 

fl

ue gas duct must be accessible to inspection.

 

Š

Inspection openings must be provided for cleaning.

 

Š

If the generator has a fume temperature lower than  160°C+ ambient temperature caused by the high yield (contact technicians) it 

MUST be resistant to humidity.

 

Š

fl

ue system that does not respect the previous points or, in general, that does not comply with the regulations, may cause condensation 

phenomena inside it.

CHIMNEY CAP

The chimney caps must meet the following requirements:

 

Š

they must have a useful outlet section no less than double that of the chimney/ducted system on which it is installed;

 

Š

they must be adapted in order to prevent the penetration of rain and snow in the chimney/ducted system;

 

Š

they must be built so that, in the event of winds coming from all directions and from any angle, the expulsion of combustion products 

is in any case ensured;

Protection  from  rain 

and wind

Condensation-proof 

"T" 

fi

tting with 

inspection plug 

Insulated 

fl

ue

Insulated "T" 

fi

tting with 

inspection plug

Protection from rain and wind

"T" 

fi

tting with 

i n s p e c t i o n 

plug

CONNECTION TO THE MAINS ELECTRIC SUPPLY

The generator is supplied with an electric power cable to be plugged into a 230V 50 Hz socket, possibly with a circuit breaker switch. The 

socket must be easily accessible.

The electrical system must be compliant with standards. The e

ffi

ciency of the earthing circuit must be checked. Unsuitable earthing of the 

system can cause malfunctioning for which the manufacturer will not be held liable. 

Power supply variations beyond 10% can cause faulty operation of the product.

FOR GERMANY ONLY

The product can be connected to a shared 

fl

ue

 (multi-connection) provided that the requirements of the regional and national regulations, 

amongst which DIN EN 13384-2, DIN V 18160-1, DIN 18896 and of the MFeuV-2007 (Muster-Feuerungsverordnung) are strictly complied with, 

and that the local chimney sweep has checked and approved the installation conditions. 

Please also remember the following indications, which the end user must comply with:

t

The device can be operated only with the doors closed.

t

The doors and all setting devices must remain closed when the device is not on (except for cleaning and maintenance operations).

Summary of Contents for COMFORT P70 AIR

Page 1: ...MADE IN ITALY design production INSERTO COMFORT P70 AIR P70 AIR PLUS 004280424 Rev 000 UK PELLET STOVES USER MANUAL...

Page 2: ...2 ENGLISH APPLY TECHNICAL DATA LABEL...

Page 3: ...AL MENU 25 GENERAL WARNINGS 25 FIRST IGNITION SETTINGS 26 DATE TIME 26 LANGUAGE 26 DEGREES 26 OPERATION AND LOGIC 27 MODES 28 FRONT AIR 28 AIR DUCTING P70 AIR PLUS ONLY 28 AIR ZONE CONTROL P70 AIR PLU...

Page 4: ...ance has been installed as well as the instructions contained in this manual The use of the appliance must comply with all local regional national and European regulations The Manufacturer cannot be h...

Page 5: ...IF IT IS DISCONNECTED FROMTHE MAINS IT IS ADVISED TO POSITION THE POWER SUPPLY CABLE SO THAT IT DOES NOT COME INTO CONTACT WITH HOT PARTS OFTHE APPLIANCE THE POWER SUPPLY PLUG MUST BE ACCESSIBLE AFTE...

Page 6: ...CLEAN THE MAJOLICAS IT IS RECOMMENDED TO USE A SOFT DRY CLOTH IF A DETERGENT OR LIQUID IS USED THE LATTER COULD PENETRATE INSIDE THE CRACKLES HIGHLIGHTING THEM SINCE THE PRODUCT CAN TURN ON AUTOMATICA...

Page 7: ...mestichotwaterproductionandinadjacentandcommunicating rooms 3 where the depression measured in situ between the external and internal environment is greater than 4 Pa N B Watertight appliances can als...

Page 8: ...lways be insulated The smoke ducts must have at least one airtight inlet for flue gas sampling All the sections of the flue gas duct must be accessible to inspection Inspection openings must be provid...

Page 9: ...S OF INSERTO COMFORT P70 AIR A Ambient air outlet E Pellet hopper I TA inlet B Access to combustion chamber and ash drawer F Fuse J 230V power supply C Emergency module G Rail K Combustion air inlet D...

Page 10: ...S A Room air outlet E Pellet hopper J 230V power supply B Access to combustion chamber and ash drawer F Air ducting Z1 outlet K Combustion air inlet C Emergency module G H Fuse Bulb thermostat reactiv...

Page 11: ...or cleaning at the end of the season If there is no pre existing chimney one can be built using an insert holder pedestal optional kit In fact the latter fixes the insert to the ground ASSEMBLY place...

Page 12: ...oor and release the latch using the poker supplied Remove the 6 screws and remove the flue pipe from the base Fix the base to the existing flue pipe ATTENTION RESPECT THE 50MM HEIGHT FOR OPENING AND C...

Page 13: ...NGLISH Fix the base to the kit if it is a new installation optional kit Block the rails with two screwdrivers and secure the flue pipe to the base with 6 screws Close the insert and block the latch 3b...

Page 14: ...ITH TOTAL MINIMUM SURFACE 240 CM UPPER PART HOT AIR OUTLET WITH TOTAL MINIMUM SURFACE 240 CM The possible set ups which must be respected are indicated below EXISTING INSTALLATION FOR INSTALLATION ON...

Page 15: ...must be guaranteed the coatings must be made of non flammable material IMPORTANT ALL THE OPENINGS CREATED FOR THE CORRECT AIR CIRCULATION MUST PREVENT THE ENTRY OF HAZARDOUS PARTS BY USING SPECIFIC GR...

Page 16: ...wise to block Holes present on two sides for the extraction of the insert via pokers Extraction of the insert allows both the pellets to be loaded inside the hopper and routine maintenance cleaning th...

Page 17: ...to very high pressures This type of fuel is fully ecological as no glues are used to hold it together Indeed the pellets remain compact over time due to a natural substance found in wood lignin As we...

Page 18: ...earms should be triggered so as to verify the cause FUSE If the stove is not powered it is recommended to have the fuse checked by a qualified technician OPTIONAL LOADING ACCESSORIES FRONT PELLET LOAD...

Page 19: ...the temperature has been reached contact open the motor will switch to minimum The duct thermostat terminal features a standard bridge See the example image COMFORT P70 AIR PLUS HOT AIR DUCTING The mo...

Page 20: ...ture from 7 to 37 C Oncethespecificactivationthresholdhasbeenreachedandexceeded attemperature to be satisfied the air ducting motor will follow the stove settings When the set TEMPERATURE is reached t...

Page 21: ...he basic operation of the stove in the event the handheld remote is damaged or malfunctions The functions that can be managed from the emergency module are Key P1 Stove ignition switch off L1 Blue LED...

Page 22: ...uccessful the display will read In this case repeat the procedure J THE RADIO CONTROL IS ALREADY CONFIGURED WITH RADIO ID 0 IF THERE IS ANOTHER STOVE TO AVOID INTERFERENCES A NEW CONFIGURATION MUST BE...

Page 23: ...ent The radio control is fitted with an LCD backlit display The display remains lit for 5 seconds After a certain period of time in order to minimise battery consumption the display turns off sleep mo...

Page 24: ...TA DISPLAY Display text Temperature detected in room Set ambient temperature Power 1 5 Hour Chrono active STAND BY active Battery low display text Time Indicates contact of the external additional th...

Page 25: ...the product it is necessary to perform the following checks If it is intended to be connected to a hydraulic system it must be complete and fully functional and in compliance with the instructions giv...

Page 26: ...to set the desired unit of measurement To set OK SETTINGS DEGREES FIRST IGNITION SETTINGS After connecting the power cord at the back of the generator turn the switch if any to position I The switch...

Page 27: ...radio control temperature probe If the contact is open fulfilled the stove works at minimum power If the contact is closed request the stove works at the set power If the setting is on HOT set above 3...

Page 28: ...O ARE INSUFFICIENT N B IF THESE ADJUSTMENTS DO NOT SOLVE THE PROBLEM OF PELLET DEPOSITS IN THE BURN POT PLEASE CONTACT YOUR LOCAL SERVICE CENTRE AIR DUCTING P70 AIR PLUS ONLY This menu allows you to s...

Page 29: ...esired power Current day and time settings are essential for the correct operation of the Chrono To set OK CHRONO PRGX ENABLING Allows the chrono and the different stove time slots to be enabled disab...

Page 30: ...00 23 00 08 00 16 30 t 22 18 2 1 30 ENGLISH Time slot 1 start 02 00 stop 23 00 Set Power 3 Set Temp 22 C Time slot 2 start 08 00 stop 16 30 Set Power 1 Set Temp 18 C stove operation Time slot Set Pow...

Page 31: ...RMOSTAT OPTIONAL STAND BY FUNCTION SET TO OFF FACTORY SETTING When the STAND BY function is not activated OFF if the stove exceeds the room temperature set on the supplementary thermostat open contact...

Page 32: ...ery life by 30 The battery life depends on the usage To set OK SETTINGS DEPRESSURE NOTICE DELAY SWITCH OFF Youcanprogramadelayedswitch offforthestove Forexample ifitis8pmandthedelayedswitch offissetto...

Page 33: ...anty CLEANING THE CERAMIC GLASS Never use abrasive or chemically aggressive detergents for cleaning The ceramic glass must be cleaned when the glass is completely cold To clean the ceramic glass simpl...

Page 34: ...Suck up the ash from the burn pot seat and combustion chamber Re position the burn pot in its slot and push it towards the fire wall and reposition the flame guard A Suck up the ash deposit from the...

Page 35: ...aults and or malfunctions which may require subsequent technical assistance Requests for routine maintenance are not covered by the warranty GASKETS PELLET HOPPER LID DOOR ASH DRAWER AND BURN POT The...

Page 36: ...36 ENGLISH HEAT EXCHANGER...

Page 37: ...d cleaning flue pipe and T fitting B Gaskets inspections door replace if necessary burn pot and heat exchanger C Combustion chamber and heat exchanger full cleaning including ignition plug pipe D Hopp...

Page 38: ...g and cleaning flue pipe and T fitting B Gaskets inspections door replace if necessary burn pot and heat exchanger C Combustion chamber and heat exchanger full cleaning including ignition plug pipe D...

Page 39: ...operation the stove will enter COOLING STAND BY and then restart automatically when the conditions are right clod stove etc AIR ZONE CONTROL This message visible in the WORK phase indicates that the...

Page 40: ...kindly asked to separate this equipment and or batteries or accumulators included from other types of waste and to arrange for disposal by the municipal waste service It is possible to ask your local...

Page 41: ...41 ENGLISH...

Page 42: ...42 ENGLISH...

Page 43: ...43 ENGLISH...

Page 44: ...ITALY 39 0445 865911 39 0445 865912 info extraflame it www lanordica extraflame com TO FIND THE SERVICE CENTRE NEAREST TO YOU CONTACT YOUR DEALER OR CONSULT THE SITE WWW LANORDICA EXTRAFLAME COM The m...

Reviews: