 Care 

&

 Cleaning

CLEAN THE SOURCE

The removable parts, including

the glass lid, upper seal, reservoir

cup, glass collector, and lower seal,

should be hand washed with a mild

soap and water.
The base where the electronics are

housed can not be put into water

at any time. To clean the base, 
gently wipe with a damp towel.

Glass lid

Narrow ring

of the upper seal

CARE FOR THE SOURCE:

It is very important to rememer the Source is an advanced piece of
technology and requires a certain degree of care to keep it in top
operating condition.

Glass Globe:  The glass globe will chip or crack if dropped or with a collision with
another object. If the glass suffers any damage the ability for a vacuum to form may
become impossible. If this happens replacement globes are available for purchase.

Crucible Cup:  The Crucible must never be tightened down onto the heating post.
Lightly turn the cup onto the threaded heating post until it meets resistance and 
stop turning.

Vacuum Relief Screw:  NEVER REMOVE the screw all the way. To release the
vacuum turn only 4 full turns to the left and wait for the pressure to equalize.
Removing the screw can result in cross threading and will make creating a
vacuum impossible. If this happens send the unit back to ExtractCraft for repairs,
but it's not covered under the manufacture defects warranty.

Green Button:  Keep green button clean and clear of any debris or sticky 
elements.  If the button becomes stuck, you can use a small amount of alcohol on 
a cotton swap then let dry over night.  If free movement is not restored, send back 
to ExtractCraft for repairs.

Summary of Contents for Source Turbo

Page 1: ...Turbo Mode User Manual...

Page 2: ...TURBO MODE USER MANUAL Version 07 September 14 2017 Part 1007 1051 ExtractCraft 105 South Sunset Street Unit M Longmont CO 80501 United States Phone 720 307 8628 customer support info extractcraft com...

Page 3: ...ractions Alcohol Solvent Source Operation Making a Plant Extract 3 Care Cleaning 9 Mobile Application 10 Installing the Mobile App Setting up Bluetooth Launch the Source App Using the Menu Understandi...

Page 4: ...n source Keep alcohol away from children and pets Always allow the outer collector to cool before opening the lid Do not immerse base unit in water or liquid of any kind PLANT EXTRACT WARNING WARNING...

Page 5: ...se petals may take hours or longer for the best result Some extracts bene t from using alcohol that has been thoroughly chilled in the freezer during the tincture process others are best prepared at r...

Page 6: ...and filters funnel for rebottling the alcohol suitable container for storing extract 3 MAKE THE TINCTURE Place clean plant matter in a clean glass container Divide large pieces into similar smaller l...

Page 7: ...make good contact with the lower seal 7 INSTALL THE RESERVOIR CUP Carefully reach inside the collector and gently screw the reservoir cup onto the threaded post Lightly screw by hand only Do not tight...

Page 8: ...11 START THE SOURCE Normal Mode Press the green button once or select the START PROCESS button on the app to start in normal mode 1 slow flash of the green button indicates the process starting 2 fast...

Page 9: ...If a seal is not established within 10 seconds check the following Make sure the vacuum relief screw located below the green button on the base closed Inspect the lower seal collector and upper seal...

Page 10: ...llector and the plant extracts remain in the reservoir cup The extraction can be ended at any point as a tincture oil sap or wax like substance otherwise known as an absolute or concrete The target co...

Page 11: ...voir from the post and transfer the extract into a storage container Store the extract in a sealed container away from direct light and heat and out of reach of pets and children 20 COLLECT ALCOHOL FO...

Page 12: ...vacuum to form may become impossible If this happens replacement globes are available for purchase Crucible Cup The Crucible must never be tightened down onto the heating post Lightly turn the cup on...

Page 13: ...rce app and under the app image tap GET Once you have the app installed you should see the Source app icon on your device CONFIRM BLUETOOTH ON Use Settings to verify that you have Bluetooth ON LAUNCH...

Page 14: ...ears tap the refresh icon 3 The refresh will display all current available units Tap the unit you want to use so it is grayed out with a check mark next to it 4 With the desired unit selected close th...

Page 15: ...the time remaining for the current cycle This can be reset to the max 120 min by turning the machine off and on Altitude Ft Reflects the default altitude that has been programmed into the unit If the...

Page 16: ...d hold the button for a full 10 seconds and release 3 Observe the lighted button flash quickly 10 times 4 Push the button once for every 1 000 feet of elevation up to 8 000 feet Sea Level no pushing j...

Page 17: ...matically stops after 120 minutes Check the consistency and taste and continue to your desired result for the peach habanero extract Add full solution directly to a full bottle of tequila or add 1 5 d...

Page 18: ...e base is ON before launching the Source app The Source process turned off but the extraction is not finished Automatic shut down due to time allowance The Source process runs for a maximum of 120 min...

Page 19: ...ot covered under warranty Before sending in a repair contact ExtractCraft at info extractcraft com for help resolving the issue If needed we will send instructions and a Return Merchandise Authorizati...

Page 20: ...ExtractCraft com 720 307 8628 info ExtractCraft com Like us on Facebook...

Reviews: