CHAPTER 28
PAGE 37
MAINTENANCE MANUAL EXTRA 300/SC
PAGE DATE: 12. February 2019
W A R N I N G
Stripping solvents can be toxic and volatile. Use only
in well ventilated areas. Avoid physical contact with
solvent and do not inhale vapors. Keep solvent contain-
ers covered when not in use.
5
Clean sealing surfaces mechanically and with Acetone.
6
Install in reverse sequence of removal after applying Scotch
Clad 776 (see Chapter 51-30-04) for sealing to both sides
of the sealing ring and the grooves inside the tank.
7
Check proper shape and installation of float wire as per para-
graph 28-40-05.
28-40-05
Float Wire
Adjustment
1
Remove the lever-type tank unit per Chapter 28-40-04.
N O T E
Figures 18 and 19 are mirror inverted also valid for
the float wire in the RH wing tank if the optional MVP-
50P is installed.
2
Remove the float wire and bend it in form like shown in the
following Figure 18:
Figure 18
Float Wire Adjustment