background image

SP505-en-GB_V1.1   10/18 

Specifications 

Display 

3 ¾ digit LCD display (3999 counts) 

Measurements 

Solar Radiation Power  

Sampling Rate 

Approximately 0.25 seconds 

Over-range Display 

“OL“ 

Tripod mount 

On rear panel 

Power 

2 x 1.5V ‘AAA’ batteries 

Battery life 

Approx. 50 hours  

Automatic power off (APO) 

After approx. 10 minutes of inactivity  

Operating Temperature/Humidity 

5 to 40

o

C (41 to 104

o

F) / 80% RH max 

Operating Altitude 

2000 meters (7000 ft.) maximum 

Storage Temperature/Humidity 

-10 to 60

o

C (14 to 140

o

F) / 70% RH max 

Dimensions/Weight 

108 x 48 x 23mm (4.3 x 1.9 x 0.9”) /80g (2.8oz) 

Safety 

For indoor use only. EMC: EN61326 (1997), A1 (1998), A2 (2001); 
Pollution degree 2 

Electrical Specifications (25±5

°

C) 

Solar Power 

Unit 

Range 

Resolution 

Accuracy* 

W/m

2

 

0 to 3999 

0.1 

±10 W/m

2

 or ±5%rdg; whichever is greater 

BTU (ft

2

*h) 

0 to 634 

0.1 

±3 BTU (ft

2

*h) or ±5%rdg; whichever is greater 

*Additional temperature error: ±0.38 W/m

or ±0.12 BTU ft

2

*h per °C from 25°C 

 

Copyright © 2018 FLIR Systems, Inc. 

All rights reserved including the right of reproduction in whole or in part in any form 

ISO-9001 Certified 

www.extech.com 

Summary of Contents for SP505

Page 1: ...USER MANUAL Solar Power Meter Model SP505 Additional User Manual Translations available at www extech com ...

Page 2: ...ations of this User Manual and for Customer Support Safety Please read the entire User Manual before operating this device Use the meter only as specified and do not attempt to service or open the meter housing Do not allow children to handle the meter Please dispose of batteries and meter responsibly and in accordance with all applicable laws and regulations Do not look directly into the sun dama...

Page 3: ...e displayed power measurement A display of OL indicates that the measured power is beyond the range of the meter Other Application Examples Automobile Headlight Measurements 1 Turn on the headlights and short press the power button to power the meter 2 Face the sensor top of meter toward one headlight and then the other recording each reading 3 Turn the high beams on and measure both headlights ag...

Page 4: ...hargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dispose of this instrument in household waste The user is obligated to take end of life devices to a designated collection point for the disposal of electrical and ele...

Page 5: ...ximum Storage Temperature Humidity 10 to 60o C 14 to 140o F 70 RH max Dimensions Weight 108 x 48 x 23mm 4 3 x 1 9 x 0 9 80g 2 8oz Safety For indoor use only EMC EN61326 1997 A1 1998 A2 2001 Pollution degree 2 Electrical Specifications 25 5 C Solar Power Unit Range Resolution Accuracy W m2 0 to 3999 0 1 10 W m2 or 5 rdg whichever is greater BTU ft2 h 0 to 634 0 1 3 BTU ft2 h or 5 rdg whichever is g...

Reviews: