Extech Instruments SDL900 User Manual Download Page 9

EXTECH

 

INSTRUMENTS

 

9

                                                      

SDL900

en

GB_V1.4

   

5/15

 

Battery

 

Replacement

 

 

When

 

the

 

low

 

battery

 

icon

 

 

appears

 

on

 

the

 

LCD,

 

the

 

batteries

 

must

 

be

 

replaced.

 

Several

 

hours

 

of

 

accurate

 

readings

 

are

 

still

 

possible

 

in

 

this

 

condition;

 

however

 

batteries

 

should

 

be

 

replaced

 

as

 

soon

 

as

 

possible:

 

 

Remove

 

the

 

two

 

(2)

 

Phillips

 

screws

 

from

 

the

 

rear

 

of

 

the

 

meter

 

(directly

 

above

 

the

 

top

 

of

 

the

 

tilt

 

stand).

 

 

Remove

 

and

 

safely

 

place

 

the

 

battery

 

compartment

 

and

 

screws

 

where

 

they

 

will

 

not

 

be

 

damaged

 

or

 

lost.

 

 

Replace

 

the

 

six

 

(6)

 

1.5V

 

‘AA’

 

batteries

 

observing

 

polarity.

 

 

Replace

 

the

 

battery

 

compartment

 

cover

 

with

 

the

 

two

 

(2)

 

Phillips

 

screws.

 

  

Note:

 

The

 

meter

 

can

 

also

 

be

 

powered

 

by

 

a

 

DC

 

9V

 

Power

 

Adapter.

 

The

 

meter

 

will

 

be

 

permanently

 

powered

 

ON

 

when

 

the

 

DC

 

adapter

 

is

 

used

 

as

 

the

 

power

 

supply

 

(the

 

power

 

button

 

function

 

is

 

disabled).

 

 
 

All EU users are legally bound by the battery ordinance to return all used batteries to 
collection points in the community or wherever batteries / accumulators are sold! 
Disposal in the household garbage is prohibited! 

 

Summary of Contents for SDL900

Page 1: ...USER GUIDE AC DC Magnetic Meter Model SDL900...

Page 2: ...al material electrical laboratory and field use DC and AC magnetic field measurements North and South pole indicator Automatic temperature compensation Zero button for DC magnetic function Separate pr...

Page 3: ...ton 4 POWER Button 5 SET Button 6 RANGE Up Arrow Button 7 FUNCTION Down Arrow Button 8 ENTER LOG Button 9 MAX MIN Button 10 RS 232 Output Terminal Side 11 Reset Button Side 12 DC 9V Power Adapter Inpu...

Page 4: ...the display will show the AC indicator The display will not show the N or S indicator Contact and press the testing material to the probe head see Fig 1 The display will show the magnetic field value...

Page 5: ...Set sampling time from 0 3600 seconds POFF Auto power OFF management BEEP Set beeper ON OFF DEC Set SD card Decimal character comma for metric or decimal for imperial SD F Format the SD memory card UN...

Page 6: ...ies the decimal function is represented by the comma symbol Use the and buttons to select USA or EURO Selecting USA enables the decimal point format Selecting EURO enables the comma format Press the E...

Page 7: ...MPTY and exit the DATALOGGER mode In this case switch the meter OFF and try again with a valid SD card 4 Pause the datalogger by pressing the LOG button momentarily The DATALOGGER icon will stop flash...

Page 8: ...ill flash each time a data point is stored Use the and buttons to select one of the 99 data memory positions in which to record To exit the manual datalogging mode press and hold the LOG button for at...

Page 9: ...battery compartment and screws where they will not be damaged or lost Replace the six 6 1 5V AA batteries observing polarity Replace the battery compartment cover with the two 2 Phillips screws Note...

Page 10: ...e 2 15 000 G x 1 G Accuracy at 23 5 C DC 5 rdg 10 dgt AC 5 rdg 20 dgt Frequency Response AC Measurement 50 Hz 60 Hz Sensor Hall Sensor Datalogger Sampling Time and Setting Range Auto 1 second to 3600...

Page 11: ...d the backlight is OFF Approx 35 mA DC If the backlight is on the power consumption increases by approximately 3 mA Weight meter and probe 303g 10 7 oz Dimensions Main Instrument 182 x 73 x 47 5 mm 7...

Reviews: