background image

6

   

                                     

SDL730-en-GB_V1.0   12/16

 

System

 

Reset

 

If

 

the

 

meter’s

 

keys

 

become

 

inoperable

 

or

 

if

 

the

 

display

 

freezes

 

the

 

Reset

 

button

 

can

 

be

 

used

 

to

 

reset

 

the

 

instrument.

 

 

Use

 

a

 

paper

 

clip

 

or

 

similar

 

item

 

to

 

momentarily

 

press

 

the

 

reset

 

button

 

located

 

on

 

the

 

lower

 

right

 

side

 

of

 

the

 

instrument

 

under

 

the

 

snap

off

 

compartment

 

cover.

 

 

After

 

pressing

 

the

 

Reset

 

button,

 

switch

 

the

 

instrument

 

ON

 

by

 

pressing

 

and

 

holding

 

the

 

POWER

 

key

 

for

 

at

 

least

 

1.5

 

seconds.

 

If

 

using

 

the

 

power

 

adaptor

 

unplug

 

the

 

adaptor

 

and

 

then

 

plug

 

it

 

back

 

in

 

again

 

to

 

power

 

the

 

meter.

 

Max

Min

 

Reading

 

Record

  

For

 

a

 

given

 

measurement

 

session,

 

this

 

meter

 

can

 

record

 

the

 

highest

 

(MAX)

 

and

 

the

 

lowest

 

(MIN)

 

readings

 

for

 

later

 

recall.

 

1.

 

Press

 

the

 

MAX

MIN

 

button

 

momentarily

 

to

 

access

 

this

 

mode

 

of

 

operation

 

(REC

 

icon

 

appears)

 

2.

 

The

 

meter

 

is

 

now

 

recording

 

the

 

MAX

 

and

 

MIN

 

readings.

 

3.

 

Press

 

the

 

MAX

MIN

 

button

 

again

 

to

 

view

 

the

 

current

 

MAX

 

readings

 

(MAX

 

icon

 

appears).

 

The

 

readings

 

on

 

the

 

display

 

are

 

now

 

the

 

highest

 

readings

 

encountered

 

since

 

the

 

REC

 

icon

 

was

 

switched

 

on

 

(when

 

the

 

MAX

MIN

 

button

 

was

 

first

 

pressed).

 

4.

 

Press

 

the

 

MAX

MIN

 

button

 

again

 

to

 

view

 

the

 

current

 

MIN

 

readings

 

(MIN

 

icon

 

appears).

 

The

 

readings

 

on

 

the

 

display

 

are

 

now

 

the

 

lowest

 

readings

 

encountered

 

since

 

the

 

REC

 

icon

 

was

 

switched

 

on

 

(when

 

the

 

MAX

MIN

 

button

 

was

 

first

 

pressed).

 

5.

 

To

 

exit

 

the

 

MAX

MIN

 

mode,

 

press

 

and

 

hold

 

the

 

MAX

MIN

 

button

 

for

 

at

 

least

 

1.5

 

seconds.

 

The

 

meter

 

will

 

beep,

 

the

 

REC

MAX

MIN

 

icons

 

will

 

switch

 

off,

 

the

 

MAX

MIN

 

memory

 

will

 

clear,

 

and

 

the

 

meter

 

will

 

return

 

to

 

the

 

normal

 

operating

 

mode.

  

Fittings

 

Connection

 

Connect

 

tubing

 

to

 

the

 

P1

 

(+),

 

P2

 

(

),

 

or

 

both

 

input

 

port(s).

 

If

 

both

 

inputs

 

are

 

used

 

(differential

 

mode),

 

the

 

meter

 

displays

 

a

 

positive

 

pressure

 

reading

 

if

 

the

 

P1

 

(+)

 

pressure

 

is

 

greater

 

than

 

P2

 

(

)

 

and

 

a

 

negative

 

reading

 

if

 

P2

 

(

)

 

is

 

greater

 

than

 

P1

 

(+).

 

Datalogging

 

Types

 

of

 

Data

 

Recording

 

 

Manual

 

Datalogging:

 

Manually

 

log

 

up

 

to

 

99

 

readings

 

onto

 

an

 

SD

 

card

 

via

 

push

button

 

press.

 

 

Automatic

 

Datalogging:

 

Automatically

 

log

 

data

 

onto

 

an

 

SD

 

memory

 

card

 

where

 

the

 

number

 

of

 

data

 

points

 

is

 

virtually

 

limited

 

only

 

by

 

the

 

card

 

size.

 

Readings

 

are

 

logged

 

at

 

a

 

rate

 

specified

 

by

 

the

 

user.

 

SD

 

Card

 

Information

 

 

Insert

 

an

 

SD

 

card

 

(from

 

1G

 

size

 

up

 

to

 

16G)

 

into

 

the

 

SD

 

card

 

slot

 

at

 

the

 

bottom

 

of

 

the

 

meter.

 

The

 

card

 

must

 

be

 

inserted

 

with

 

the

 

front

 

of

 

the

 

card

 

(label

 

side)

 

facing

 

toward

 

the

 

rear

 

of

 

the

 

meter.

 

 

If

 

the

 

SD

 

card

 

is

 

being

 

used

 

for

 

the

 

first

 

time

 

it

 

is

 

recommended

 

that

 

the

 

card

 

be

 

formatted

 

and

 

the

 

logger’s

 

clock

 

set

 

to

 

allow

 

for

 

accurate

 

date/time

 

stamping

 

during

 

datalogging

 

sessions.

 

Refer

 

to

 

the

 

Setup

 

Mode

 

section

 

for

 

SD

 

card

 

formatting

 

and

 

time/date

 

setting

 

instructions.

 

Summary of Contents for SDL730

Page 1: ...User Manual Heavy Duty Differential Pressure Manometer Model SDL730 Additional User Manual Translations available at www extech com ...

Page 2: ...User Guide and Customer Support Safety International Safety Symbols This symbol adjacent to another symbol or terminal indicates the user must refer to the manual for further information Meter Description 1 P1 Input positive 2 P2 Input negative 3 LCD Display 4 HOLD and Backlight key 5 MAX MIN key 6 SET and Clock key 7 RS232 output jack 8 Reset button 9 Power Adaptor jack 10 SD card slot 11 ENTER a...

Page 3: ...er is disabled Units of Measure The currently selected unit of measure is shown below the measurement value on the meter s LCD To change the unit of measure press and hold the UNIT button until the desired unit of measure appears and then release the UNIT button The meter begins scrolling through the available units of measure see table below after the UNIT button has been depressed for at least 1...

Page 4: ...ormation is provided below this list dAtE Set the clock Year Month Date Hours Minutes Seconds SP t Set the datalogger sampling rate Hours Minutes Seconds PoFF Automatic power off management Enable or disable the auto power off function bEEP Set the beeper sound ON OFF dEC Set the numerical format USA decimal 20 00 or European comma 20 00 SdF Format the SD memory card Setting the Clock Time 1 Acces...

Page 5: ...ait 7 seconds for the meter to automatically switch to the normal operating mode Numerical Format comma or decimal European and USA numerical formats differ The meter defaults to USA mode where a decimal point is used to separate units from tenths i e 20 00 The European format uses a comma i e 20 00 to separate units from tenths To change this setting 1 Access the dEC parameter 2 Use the arrow but...

Page 6: ...dings encountered since the REC icon was switched on when the MAX MIN button was first pressed 5 To exit the MAX MIN mode press and hold the MAX MIN button for at least 1 5 seconds The meter will beep the REC MAX MIN icons will switch off the MAX MIN memory will clear and the meter will return to the normal operating mode Fittings Connection Connect tubing to the P1 P2 or both input port s If both...

Page 7: ... change the sampling rate refer to the Setup Mode section the sampling rate cannot be 0 for automatic datalogging 1 Select the sampling rate in the Setup Mode to a value other than zero 2 Press and hold the LOG button for at least 1 5 seconds The meter will flash the DATALOGGER icon at the selected sampling rate indicating that readings are now being automatically recorded to the SD card 3 If a ca...

Page 8: ...d 3 Plug the SD Card directly into a PC SD card reader If the PC does not have an SD card slot use an SD card adaptor available at most outlets where computer accessories are sold 4 Power the PC and run a spreadsheet software program Open the saved documents in the spreadsheet software program see example spreadsheet data screen below Spreadsheet data example AC Power Adaptor This meter is normall...

Page 9: ...9 SDL730 en GB_V1 0 12 16 Hose Couplings This meter is supplied with a pair of hose couplings They fit 4 0mm 0 157 tubing See diagram on how to connect these couplings to the hose and the meter ...

Page 10: ...orrect polarity Replace the battery compartment cover with the two 2 Phillips screws Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dispose of this instrument in household wast...

Page 11: ...in 59 sec Data lose may occur when logging at a 1 second rate MANUAL LOGGING Set the sampling rate to 0 seconds Select 1 to 99 locations Data error number 0 1 number of total saved data Memory Card SD memory card 1G to 16GB size Data Hold Freeze the displayed reading Memory Recall Record and Recall the Maximum and Minimum readings Display update rate Approx 1 second Operating Temperature 0 to 50 C...

Page 12: ... 1 700 0 kPa 0 5 7000 hPA 5 2810 inches H2O 2 71 35 m H2O 0 05 6 905 ATP 0 005 Conversions Useful conversion Factors From To Multiplier in of H2O in of Hg 0 07355 in of H2O cm of H2O 2 54 mm of Hg in of H2O 0 53524 Copyright 2016 FLIR Systems Inc All rights reserved including the right of reproduction in whole or in part in any form ISO 9001 Certified www extech com ...

Reviews: