Maintenance 

Battery Replacement 

When the ON LED begins to flash, the batteries need to be replaced. 

1. 

Remove the clips from any conductors. 

2. 

Remove the screw holding the battery compartment cover and remove the cover. 

3. 

Replace the four AA batteries. 

4. 

Replace the battery cover. 

 

You, as the end user, are legally bound (

Battery ordinance

) to return all used batteries 

and accumulators; 

disposal in the household garbage is prohibited!

 

You can hand over your used batteries / accumulators at collection points in your 
community or wherever batteries / accumulators are sold! 

Disposal: 

Follow the valid legal stipulations in respect of the disposal of the device at the 

end of its lifecycle. 

 

Cleaning and storage 

Periodically wipe the case with a damp cloth. Do not use abrasives or solvents.  

A small standby current flows when the meter is off. If the meter is not to be used for a period longer 
than 60 days, remove the batteries and store them separately. 

Specifications 

Measurement Principle  

Static induction  

Input Voltage  

75 to 1000VAC  

Frequency Range  

45 to 65Hz  

Max conductor diameter 

33mm (1.3”) 

Probe length 

86cm (34”) 

Auto-Off  

5 min. without sequence detection  

Low Battery Warning  

Power LED flashes  

Batteries 

4 x 1.5V AA 

Current consumption  

15mA  

Operating Temperature & Humidity  

-10°C to 50°C (14°F to 122°F) Max. 80% R.H.  

Storage temperature & Humidity  

-20°C to 60° (-4°F to 140°F) Max. 80% R.H.  

Safety 

This meter is intended for origin of installation use and 
protected, against the users, by double insulation per 
EN61010-1 to Category IV 600V and Category III 1000V; 
Pollution Degree 2.  

Approvals CE 

 

Copyright 

©

 2011 Extech Instruments Corporation (a FLIR company) 

All rights reserved including the right of reproduction in whole or in part in any form. 

 

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com 

Summary of Contents for PRT200

Page 1: ...User s Guide Non Contact Phase Rotation Tester Model PRT200 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com ...

Page 2: ...dicates that under normal use hazardous voltages may be present Double insulation Safety Notes 1 Read the following safety information carefully before attempting to operate the tester 2 Use the tester only as specified in this manual or the protection provided by the tester may be impaired 3 This instrument cannot identify a missing earth line 4 To assure accurate results do not touch the clips d...

Page 3: ...ce LED 2 Rotation LEDs 3 Live indication LEDs 4 Power on and low battery LED 5 Power switch 6 Brightness switch 7 Counter Clockwise phase sequence LED 8 Rotation LEDs 9 Buzzer 1 Magnets 2 Battery compartment cover 3 Battery compartment screw 1 2 1 3 1 2 3 4 5 6 7 8 9 7 ...

Page 4: ...ate Indication Three live conductors L1 L2 L3 LEDs are ON Open phases L1 L2 or L3 LED is OFF for open phases Missing Earth line LED does not light up for missing earth line Earth line Delta connection Phase with flashing LED is an earth phase Positive CW phasing The CW Rotation LEDs flash in clockwise direction as indicated with arrow marks The buzzer sounds intermittently Negative CCW phasing The...

Page 5: ...current flows when the meter is off If the meter is not to be used for a period longer than 60 days remove the batteries and store them separately Specifications Measurement Principle Static induction Input Voltage 75 to 1000VAC Frequency Range 45 to 65Hz Max conductor diameter 33mm 1 3 Probe length 86cm 34 Auto Off 5 min without sequence detection Low Battery Warning Power LED flashes Batteries 4...

Reviews: