Introduction 

Congratulations on your purchase of Extech model MM560 or MM570 
digital multimeter. Properly used, this meter will provide many years of 
reliable service. 
 
MultiMaster™ Meters provides high resolution, high accuracy, true rms 
measurements of AC Voltage and Current, DC Voltage and Current, 
AC+DC, Resistance, Frequency, Capacitance, Duty Cycle, dBm, Peak, 
%4-20, Diode, and Continuity. The MultiMaster™ also offers RS-232 PC 
Interface data acquisition capabilities as an option. Model MM570 offers 
dual input Temperature measurements and very wide bandwidth. 

Safety 

International Safety Symbols 

 

!

  Caution !  Refer to the explanation in this Manual 

  Caution !  Risk of electric shock 

 Earth 

(Ground) 

  Double Insulation or Reinforced insulation 

 Fuse 

 

AC, Alternating Current or Voltage 

  DC, Direct Current or Voltage 

 

AC+DC, Current or Voltage 

 

Safety Precautions 

1.  Improper use of this meter can cause damage, shock, injury or death. 

Read and understand this users manual before operating the meter. 

2.  Make sure any covers or battery doors are properly closed and 

secured. 

3.  Always remove the test leads before replacing the battery or fuses. 
4.  Inspect the condition of the test leads and the meter itself for any 

damage before operating the meter. Repair or replace any damage 
before use. 

5.  To reduce the risk of fire or electric shock, do not expose this product 

to rain or moisture. 

6.  Do not exceed the maximum rated input limits. 

Summary of Contents for MultiMaster MM560

Page 1: ...User s Guide MultiMaster Digital MultiMeter Series With PC Interface Models MM560 MM570...

Page 2: ...prevent damage in transit This warranty does not apply to defects resulting from action of the user such as misuse improper wiring operation outside of specification improper maintenance or repair or...

Page 3: ...fer to the explanation in this Manual Caution Risk of electric shock Earth Ground Double Insulation or Reinforced insulation Fuse AC Alternating Current or Voltage DC Direct Current or Voltage AC DC C...

Page 4: ...that the terminals are not live 12 If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired 13 The product is intended only for...

Page 5: ...DC CURRENT Range Accuracy Burden Voltage 500 00 A 0 15 20d 0 15mV A 5000 0 A 0 1 20d 0 15mV A 50 000mA 0 15 10d 3 3mV mA 500 00mA 0 1 20d 3 3mV mA 5 0000A 0 5 10d 0 03V A 10 000A 0 5 20d 0 03V A 10A c...

Page 6: ...o 20kHz 1kHz to 20kHz 500 00mV 0 5 20d 1dB 5 0000V 50 000V 0 8 20d 2dB 500 00V 0 5 20d 3dB 1000 0V Unspecified Unspecified 20kHz to 100kHz 500 00mV 2 0 40d 5 0000V 50 000V 4 0 40d 500 00V 1000 0V Unsp...

Page 7: ...000mA 500 00mA 3 3mV mA 5 0000A 10 000A 0 7 50d 1 0 40d 0 03V A 1kHz to 10kHz 500 00 A 5000 0 A 0 15mV A 50 000mA 500 00mA 2 0 50d 3 3mV mA 5 0000A 10 000A Unspecified Unspecified 0 03V A 10A continuo...

Page 8: ...range 10V min 500V range 100V min Sensitivity 1000V range 900V min FREQUENCY LOGIC LEVEL Range 5 0000Hz to 2 00000MHz Accuracy 0 002 4d Sensitivity 2 5Vp square wave DUTY CYCLE Range 0 10 to 99 99 Acc...

Page 9: ...equency bandwidth for non sinusoidal waveforms Sensing DC AC True RMS AC DC True RMS Digital Display 4 4 5 digits 50000 count 5 4 5 digits 500000 count for DCV 6 digits 999999 count for Hz Bar Graph D...

Page 10: ...for DMMs was first released in IEC61010 1 2nd Edition in year 2001 and was yet an UL published standard at the time this manual was written E M C Meets EN61326 1997 1998 A1 EN61000 4 2 1995 and EN6100...

Page 11: ...he average value is then scaled upward calibrated to read the RMS value of a sine wave In measuring pure sinusoidal waveform this technique is fast accurate and cost effective In measuring non sinusoi...

Page 12: ...the AC bandwidth of the DMM Therefore wide AC bandwidth plays an important role in a high performance DMM In reality complex waveforms noise and distorted waveforms contain a much higher frequency spe...

Page 13: ...multimeters are Autoranging with manual override Smart Power Auto Power Off APO Smart Power automatically shuts the meter down after approximately 17 minutes of inactivity APO can be disabled on powe...

Page 14: ...T key to toggle between AC and dBm 4 In VDC press the SELECT key to toggle between DC and AC DC 5 In mV press the SELECT key to toggle between DC AC and AC DC 6 Read the voltage measurement on the dis...

Page 15: ...an the phase to earth voltage To avoid accidentally exceeding the voltage rating of the protection fuse s always consider the phase to phase voltage as the working voltage for the protection fuse s 4...

Page 16: ...15 6 For Continuity tests if the resistance is less than the threshold 20 to 200 an audible tone will sound...

Page 17: ...nge to automatically get the most appropriate trigger level When activated from voltage function you can also press the RANGE key momentarily to select another trigger level range manually The analog...

Page 18: ...only 1 Insert the T1 Temperature Probe into the COM and TEMP input jacks observing polarity 2 Insert the T2 Temperature Probe into the 10A and mA A input jacks observing polarity 3 Set the function s...

Page 19: ...be disabled automatically in this mode Smart Power Auto Power Off Smart Power shuts the meter down automatically after approximately 17 minutes of inactivity The 17 minute time period is reset any tim...

Page 20: ...the meter from any circuit remove the test leads from the input jacks and turn OFF the meter before opening the case Do not operate with open case Install only the same type of fuse or equivalent Cle...

Page 21: ...M6 IEC6LF22 FS1 for A mA current input For MM560 0 63A 500V F IR 200kA fast acting fuse For MM570 1A 1000V F IR 10kA acceptable alternative 0 44A 1000V IR 10kA FS2 for A current input For MM560 12 5A...

Reviews: