background image

MO297-EU-EN V4.3   4/13 

6

Condensation Mode 

The Condensation feature alerts the user when the surface temperature as measured by the IR 
thermometer is close to or has reached the Dew Point temperature. 

1.  Press the power 

 button to turn the meter on. 

2.  Simultaneously press the MOIST and RH buttons. The “COND” icon will appear. 
3.  Point the meter at a surface, press the IRT button to measure the surface temperature. The 

small display will indicate the IR surface temperature and the large display will indicate the 
difference between the IR temperature and the Dew Point temperature. 

4.  The meter will then report the potential for condensation on that surface in the following 

manner 

  If the temperature of the IRT is more than 14°C (25°F) above the Dew Point, the 

temperature difference shall be displayed, with no other warning. 

  If the temperature of the IRT is 3-14°C (5-25°F) above the Dew Point, the temperature 

difference shall be displayed, along with a standard Condensation Indicator icon.  The meter 
shall beep once to confirm that the reading is in the risk area. 

  If the temperature of the IRT is less than 3°C (5°F) above the Dew Point, the temperature 

difference shall be displayed, along with a flashing Condensation Indicator icon.  The meter 
shall beep twice to confirm that the reading is in the high-risk area. 

5. 

Press the RH button to exit the mode. 

Vapor Pressure Mode 

Ambient Vapor Pressure 

1.  With the Condensation mode active, press the MODE button to display the Vapor Pressure in 

mBAR (°F) or kPa (°C). Press the 

or 

button to toggle between mBAR or kPa. 

2.  Press the MODE button to exit the Vapor Pressure mode. 

Surface Vapor Pressure 

1. 

Enter the Vapor Pressure mode as described above. 

2. 

Press the IRT button and aim the laser pointer at the surface to be measured  to display the 
Surface Vapor Pressure in mBAR (°F) or kPa (°C). 

Alarm High and Low Limit Setting 

High and Low alarm points can be set for Humidity and Moisture measurements. 
Humidity Alarm Set Procedure: 

1.  With RH% displayed, simultaneously press the RH and MODE buttons. 
2.  The “HIGH” icon will appear on the display. 
3. Press 

the 

or 

button to set the high limit desired. 

4.  Press the STORE/ALARM SET button to save the value and proceed to the LOW set value. 
5.  With the “LOW” icon in the display, Press the 

or 

button to set the low limit desired. 

6.  Press the STORE/ALARM SET button to save the value and to return to the normal mode. 
7.  If the humidity measurement is lower than the low alarm setting or higher than the high alarm 

setting, the meter will beep once every second. 

 

Summary of Contents for MO297

Page 1: ...User s Guide Pinless Moisture Humidity Meter with IR Thermometer Bluetooth Model MO297...

Page 2: ...reliable service Meter Description 1 IR temperature sensor 2 Laser pointer 3 Humidity sensor 4 Temperature sensor 5 LCD display 6 Relative Humidity button 7 Mode Zero Button 8 IR thermometer button 9...

Page 3: ...t surface temperature 8 1 distance to spot ratio with 0 95 fixed emissivity Built in Humidity Temperature probe measures Relative Humidity Air Temperature plus Grains Per Pound GPP and Dew Point DP Am...

Page 4: ...int 6 Press the MODE button to display GPP F or g kg C Press the or button to toggle between GPP or g kg Pinless Moisture Measurements 1 Press the power button to turn the meter on 2 Press the MOIST b...

Page 5: ...ble the IR thermometer The meter will display the minimum temperature measured and will update only when a lower temperature is measured 3 Press the MODE button twice to enable the MAX mode and procee...

Page 6: ...shall be displayed along with a flashing Condensation Indicator icon The meter shall beep twice to confirm that the reading is in the high risk area 5 Press the RH button to exit the mode Vapor Pressu...

Page 7: ...the unit beeps The data will be saved to the memory location indicated The numeric display above the MEM icon will then advance to the next location 2 When the 20 memory locations are full the unit w...

Page 8: ...he button for two seconds The Bluetooth icon will appear in the display 2 Pair the meter to the camera by following the Pairing Bluetooth Devices section in the thermal camera manual 3 Once paired the...

Page 9: ...al identifying marker 4 Recall the reading from memory The moisture meter will now continuously transmit this reading via Bluetooth 5 Use the camera to take a thermal image of the area with the identi...

Page 10: ...ure and RH measurements Dew Point 30 to 100 C 22 to 199 F Mixing Ratio 0 999GPP 0 to 160g kg Sample Rate 2 per second Backlight White LED Memory 20 point memory Bluetooth range 32 feet 10 meters appro...

Reviews: