Specifications 

 

Function Range 

Resolution 

 

Accuracy 

DC Voltage 
(V DC) 

200mV 0.1mV 

 (0.5% r 2 digits) 

2000mV 1mV 
20V 0.01V 
200V 0.1V 
600V 1V 

AC Voltage 
(V AC) 

200V 0.1V 

 (1.2% r 10 digits 

   (50/60Hz) 

600V 1V 

DC Current 
(A DC) 

2000

A 1

 (1.0% r 2 digits) 

20mA 

10

200mA 

100

 (1.2% r 2 digits) 

10A 10mA 

 (2.0% r 2 digits) 

Resistance 

200

 0.1

 

 (0.8% r 2 digits) 

2000

 

1

 

20k

 0.01k

 

200k

 0.1k

 

2000k

 1k

 

 (1.0% r 2 digits) 

Battery Test 

9V 

10mV 

 (1.0% r 2 digits) 

 1.5V 

10mV 

 

Input Limits 
Function Maximum 

Input 

VAC 600VDC/VAC 
VDC 

600VDC, 600VAC, 200Vrms on 200mV range 

Ohms, Continuity 

220Vrms for 15sec max 

mA DC 

200mA, 250V fast acting fuse 

10A DC 

10A, 250V fast acting fuse 

 
NOTE:

 Accuracy is stated at 65

o

F to 83

o

F (18

o

C to 28

o

C) and less than 75% RH. 

www.ponpe.com

contact:

[email protected]

Summary of Contents for MiniTec MN24

Page 1: ...User s Manual MiniTecTM Series MultiMeter Model MN24 www ponpe com contact sale ponpe com...

Page 2: ...he meter 2 Make sure any covers or battery doors are properly closed and secured 3 Always remove the test leads before replacing the battery or fuses 4 Inspect the condition of the test leads and the...

Page 3: ...ositive jack Note Tilt stand fuse and battery compartment are located on the rear of the unit Symbols Continuity Diode test micro amps m milli volts amps k kilo ohms ohms VDC volts direct current VAC...

Page 4: ...ve mA jack for currents to 200mA b Positive 10A jack for currents to 10A 2 Turn the rotary switch to the ADC range needed 3 Touch the test probes in series with the circuit under test and read the cur...

Page 5: ...s will indicate near 0mV and an open device will indicate I in both polarities Battery Test 1 Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into t...

Page 6: ...e meter in mild ambient conditions Temperature extremes can shorten the life of the electronic parts and distort or melt plastic parts 3 Handle the meter gently Dropping it can damage the electronic p...

Page 7: ...he battery door and secure with the screw Fuse Replacement WARNING To avoid electric shock disconnect the test leads from any source of voltage before removing rear cover 1 Disconnect the test leads f...

Page 8: ...ng 2 digits 10A 10mA 2 0 reading 2 digits Resistance 200 0 1 0 8 reading 2 digits 2000 1 20k 0 01k 200k 0 1k 2000k 1k 1 0 reading 2 digits Battery Test 9V 10mV 1 0 reading 2 digits 1 5V 10mV Input Lim...

Page 9: ...w operating voltage Battery one 9 volt NEDA 1604 battery Fuses mA A ranges 0 2A 250V fast blow A range 10A 250V fast blow Operating Temperature 32 o F to 122 o F 0 o C to 50 o C Storage Temperature 4...

Page 10: ...ages FLIR s total liability is limited to repair or replacement of the product The warranty set forth above is inclusive and no other warranty whether written or oral is expressed or implied Calibrati...

Reviews: