Operation

 

NOTES

:

 

Read

 

and

 

understand

 

all

 

Warning

 

and

 

Caution

 

statements

 

in

 

this

 

operation

 

manual

 

prior

 

to

 

using

 

this

 

meter.

 

Meter

 

Power

 

The

 

meter

 

is

 

powered

 

by

 

two

 

(2)

 

AAA

 

1.5V

 

batteries

 

(located

 

in

 

compartment

 

on

 

bottom

 

of

 

meter

 

handle).

 

Press

 

and

 

hold

 

the

 

Power

 

button

 

for

 

>

 

2

 

seconds

 

to

 

switch

 

the

 

device

 

ON

 

or

 

OFF.

 

When

 

the

 

meter

 

switches

 

ON

 

the

 

display

 

shows

 

the

 

battery

 

status

 

(FULL,

 

for

 

example).

 

There

 

is

 

also

 

a

 

battery

 

status

 

icon

 

displayed

 

on

 

the

 

lower

 

right

 

hand

 

corner

 

of

 

the

 

LCD.

 

Low

 

battery

 

indication

 

When

 

the

 

displayed

 

battery

 

icon

 

appears

 

empty

 

or

 

if

 

the

 

power

 

ON

 

battery

 

status

 

message

 

indicates

 

weak

 

battery

 

power,

 

the

 

batteries

 

should

 

be

 

replaced

 

immediately.

 

Refer

 

to

 

the

 

battery

 

replacement

 

procedure

 

in

 

the

 

maintenance

 

section.

 

Automatic

 

Power

 

OFF

 

The

 

meter

 

switches

 

OFF

 

automatically

 

after

 

a

 

20

 

minute

 

period

 

of

 

inactivity

 

(±30

 

seconds).

 

To

 

disable

 

the

 

Auto

 

Power

 

OFF

 

feature:

 

 

With

 

the

 

meter

 

power

 

OFF,

 

press

 

and

 

hold

 

the

 

Power

 

button

 

for

 

>2

 

seconds

 

 

When

 

the

 

display

 

shows

 

the

 

battery

 

status

 

(FULL,

 

for

 

example),

 

press

 

the

 

backlight

 

button

 

until

 

the

 

display

 

shows

 

‘AoFF’.

  

 

The

 

APO

 

feature

 

is

 

now

 

disabled

 

and

 

the

 

meter

 

will

 

not

 

shut

 

off

 

automatically.

 

 

Note

 

that

 

the

 

next

 

time

 

the

 

meter

 

is

 

powered

 

up,

 

the

 

Auto

 

Power

 

OFF

 

function

 

will

 

be

 

re

enabled

  

and

 

the

 

user

 

will

 

have

 

to

 

repeat

 

the

 

Auto

 

Power

 

OFF

 

disable

 

instructions

 

to

 

disable

 

this

 

function

 

when

 

desired.

 

Backlit

 

LCD

 

Press

 

the

 

backlight

 

button

 

to

 

switch

 

the

 

LCD

 

backlight

 

ON

 

or

 

OFF.

 

Note

 

that

 

excessive

 

use

 

of

 

the

 

backlight

 

feature

 

will

 

shorten

 

battery

 

life.

 

Data

 

Hold

 

Press

 

the

 

HOLD

 

button

 

with

 

the

 

meter

 

ON

 

to

 

freeze

 

the

 

displayed

 

reading.

 

The

 

HOLD

 

icon

 

will

 

appear

 

along

 

with

 

the

 

held

 

reading.

 

Press

 

the

 

HOLD

 

button

 

again

 

to

 

release

 

the

 

HOLD

 

feature.

 

The

 

HOLD

 

icon

 

will

 

switch

 

OFF

 

and

 

the

 

meter

 

will

 

show

 

real

 

time

 

readings.

  

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for MA3010

Page 1: ...USER GUIDE 3000A TRUE RMS AC Flexible Clamp Meters Model MA3010 and MA3018 www com information itm com 1 800 561 8187...

Page 2: ...uments that offer Auto Power OFF Data Hold and backlight features This meter is shipped fully tested and calibrated and with proper use will provide years of reliable service Features 3000A AC True RM...

Page 3: ...expose this product to rain or moisture Verify the meter operation by measuring a known current If in doubt have the meter serviced Do not apply more than the rated voltage current as marked on the m...

Page 4: ...t of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which measures are taken to limit the transient over voltages to an appropriate low level Note Examples include protected electro...

Page 5: ...Power Hold button 3 Battery Compartment 4 Backlight button 5 LCD display 6 Clamp Lock mechanism Display Icons HOLD Data Hold A Amperes Current Minus symbol negative FULL Battery status message on pow...

Page 6: ...y after a 20 minute period of inactivity 30 seconds To disable the Auto Power OFF feature With the meter power OFF press and hold the Power button for 2 seconds When the display shows the battery stat...

Page 7: ...to the device under test 2 Turn the knurled clamp lock mechanism counter clockwise to release the flexible clamp 3 Fully enclose only one conductor of the device under test with the flexible clamp pr...

Page 8: ...ery compartment 1 With a flat blade screwdriver or coin rotate the battery compartment cover to the unlock position 2 Remove the battery compartment cover 3 Replace the 2 AAA 1 5V batteries observing...

Page 9: ...ntralized primary conductor at optimum position no external electrical or magnetic field and within operating temperature range MA3010 MA3010 Error MA3018 MA3018 Error Distance from optimum position 1...

Page 10: ...racy C 18 C 64 5 F 28 C 82 4 F Altitude Maximum operating altitude 2000m 6562 Battery Two AAA 1 5V batteries Battery life 200 hours with alkaline batteries Auto power OFF After approx 20 minutes of in...

Reviews: