Operation 

Meter Power 

Power the meter by long pressing the 

 button. The meter will begin displaying light intensity 

readings. If the LCD does not switch on, check the batteries located in the rear battery 
compartment. Short press power button to turn OFF the meter. 

Zero Calibrate the Sensor 

1.

 

Place the protective cover over the sensor and press the 

 button to power on the meter. 

2.

 

If the display does not read ‘0.0’ short press the 

 button. 

3.

 

The CAL icon will appear in the secondary display. 

4.

 

The CAL icon will switch OFF when the calibration has been completed. 

5.

 

If the protective cap is not covering the sensor when the 

 button is pressed, the LCD 

display will read “CAP”.  In this case, please cover the sensor with the cap and restart this 
procedure.  

6.

 

It is recommended that the meter be switched off and then on again when repeating the 

zero calibration function. 

Taking Measurements 

Remove the sensor cover and aim the sensor toward the light source. View the measurement on 
the meter’s display. 

Selecting the Unit of Measure 

Press the 

 button to toggle the units between Lux and Foot-candles. The units will indicate in 

the display. 

Data Hold 

Short press the   button to freeze or unfreeze a reading on the display.  

 

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for LT505

Page 1: ...USER MANUAL LUX FC Light Meter Model LT505 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 2: ...entire User Manual before operating this device Use the meter only as specified and do not attempt to service or open the meter housing Do not use the meter in the presence of explosive gas or vapor D...

Page 3: ...appear in the secondary display 4 The CAL icon will switch OFF when the calibration has been completed 5 If the protective cap is not covering the sensor when the button is pressed the LCD display wil...

Page 4: ...press the button The MAX AVG MIN display icons will switch off and the meter will return to normal operating mode Auto Power OFF APO In order to conserve battery life the meter will automatically shut...

Page 5: ...ve the battery and store separately Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collectio...

Page 6: ...ter Power 2 x 1 5V AAA batteries Low battery indicator included Automatic power off After approx 12 minutes of inactivity Operating Temp Humidity 5 C to 40 C 40 F to 104 F 80 RH Max Operating Altitude...

Page 7: ...tions 23 5 C Lux autorange Unit Range Resolution Accuracy Lux 999 9 0 1 3 rdg 3 dgts 9 999 1 3 rdg 10 dgts 99 990 10 400 000 100 Foot candle autorange Unit Range Resolution Accuracy fc 99 99 0 01 3 rd...

Page 8: ...om Dining Table 750 1 500 75 150 Clerical Work 750 1 500 75 150 Show Window 1 500 2 000 150 2000 Typing Drafting Store Hospital 75 150 7 15 Indoors 30 75 3 7 Emergency Stairs 150 200 15 20 Corridor St...

Reviews: