background image

2

                                                     

IR270

en

GB_V1.0

   

12/17

 

Introduction

 

Thank

 

you

 

for

 

selecting

 

the

 

Extech

 

IR270

 

IR

 

Thermometer.

 

The

 

IR270

 

makes

 

non

contact

 

(infrared)

 

surface

 

temperature

 

measurements

 

and

 

includes

 

a

 

laser

 

pointer

 

for

 

convenient

 

targeting.

 

The

 

meter

 

switches

 

ON

 

and

 

starts

 

scanning

 

surface

 

temperatures

 

as

 

soon

 

as

 

you

 

pull

 

the

 

trigger.

 

This

 

device

 

is

 

shipped

 

fully

 

tested

 

and

 

calibrated

 

and,

 

with

 

proper

 

use,

 

will

 

provide

 

years

 

of

 

reliable

 

service.

 

Please

 

visit

 

our

 

website

 

(www.extech.com)

 

to

 

check

 

for

 

the

 

latest

 

version

 

and

 

translations

 

of

 

this

 

User

 

Manual

 

and

 

Customer

 

Support.

 

Features

 

 

Measures

 

non

contact

 

surface

 

temperature

 

up

 

to

 

650°C

 

(1202°F)

 

 

Automatic

 

ranging

 

 

12:1

 

Distance

 

to

 

Spot

 

Ratio

 

(Field

 

of

 

View)

 

 

Laser

 

pointer

 

targeting

 

 

Automatic

 

Data

 

Hold

 

when

 

trigger

 

is

 

released

 

 

High/Low

 

temperature

 

alarms

 

 

Maximum,

 

Minimum,

 

Average,

 

and

 

Differential

 

displays

 

 

20

memory

 

datalogger

 

 

Selectable

 

emissivity

 

 

Display

 

backlight

 

 

Selectable

 

temperature

 

units

 

(°F

 

/

 

°C)

 

 

Battery

 

status

 

indication

 

Safety

 

International

 

Safety

 

Symbols

 

This

 

symbol,

 

adjacent

 

to

 

another

 

symbol

 

or

 

terminal,

 

indicates

 

the

 

user

 

must

 

refer

 

to

 

the

 

manual

 

for

 

further

 

information

 

Warnings

 

o

 

Do

 

not

 

directly

 

or

 

indirectly

 

point

 

the

 

laser

 

at

 

the

 

eyes

 

of

 

a

 

person

 

or

 

an

 

animal

 

o

 

Inspect

 

for

 

damage

 

or

 

for

 

any

 

shortage

 

of

 

parts

 

or

 

accessories

 

before

 

use

 

o

 

Replace

 

the

 

battery

 

immediately

 

after

 

the

 

battery

 

indicator

 

flashes

 

o

 

Do

 

not

 

use

 

the

 

thermometer

 

near

 

explosive

 

gases,

 

steam,

 

or

 

dust

 

o

 

Note

 

that

 

an

 

object

 

with

 

high

 

reflectivity

 

will

 

normally

 

cause

 

the

 

measured

 

temperature

 

value

 

to

 

read

 

much

 

lower

 

than

 

the

 

actual

 

temperature

 

o

 

Use

 

the

 

device

 

only

 

as

 

described

 

in

 

this

 

User

 

Manual

 

Cautions

 

To

 

avoid

 

thermometer

 

damage,

 

please

 

avoid

 

the

 

following

 

hazards:

 

o

 

EMF

 

from

 

welding

 

equipment

 

or

 

electro

induction

 

heaters

 

o

 

Static

 

electricity

 

o

 

Thermal

 

shock

 

caused

 

by

 

large

 

or

 

abrupt

 

environmental

 

temperature

 

changes;

 

wait

 

30

 

minutes

 

to

 

allow

 

the

 

thermometer

 

to

 

stabilize

 

to

 

new

 

environmental

 

conditions

 

o

 

Do

 

not

 

use

 

this

 

device

 

in

 

excessively

 

high

 

temperature

 

environments

  

 

<1mW Output at 650nm

Summary of Contents for IR270

Page 1: ...User Manual InfraRed Thermometer With Laser Pointer and High Low Alarms Model IR270 Additional User Manual Translations available at www extech com ...

Page 2: ...mperature units F C Battery status indication Safety International Safety Symbols This symbol adjacent to another symbol or terminal indicates the user must refer to the manual for further information Warnings o Do not directly or indirectly point the laser at the eyes of a person or an animal o Inspect for damage or for any shortage of parts or accessories before use o Replace the battery immedia...

Page 3: ... Scan mode The icon flashes while the trigger is pulled The displayed reading represents the temperature of the scanned surface 2 Data hold mode Reading is held after trigger is released 3 Primary display Surface temperature reading 4 Datalogger mode 5 Secondary display mode icons EMS MAX MIN DIF AVG HAL LAL 6 Secondary Display value 7 Battery status icon Flashes when battery voltage is critically...

Page 4: ...nd then the meter will automatically shut off 5 Refer to the Field of View section for distance to target spot ratio considerations 6 The meter defaults to the programmed conditions in use when the meter was last switched OFF For example if the laser is set to default to ON and the temperature units are set to o F at the time the unit is switched OFF the unit will switch ON and use the same settin...

Page 5: ...mpensates for deviations in ambient temperature but it can take up to 30 minutes for the meter to adjust to wide ambient temperature changes 7 To find a hot spot aim the meter outside the area of interest then scan in an up and down motion until the hot spot is located Secondary Display Modes The secondary display area is located on the bottom of the meter s LCD You can step through the secondary ...

Page 6: ...ngs recorded during the last measurement scan performed High Alarm Limit HAL Use the M button to step to the HAL parameter Use the arrow buttons to set the High Alarm limit While measuring the meter beeps when the displayed reading is higher than the high alarm setting If the backlight is on the backlight color will turn red in a high alarm condition Low Alarm Limit LAL Use the M button to step to...

Page 7: ...applied to cover the measured surface Wait a period of time to allow the tape or paint to reach thermal equilibrium with the surface of the covered object Measure the temperature of the surface covered with tape or paint only Emissivity Factors for Common Materials Material under test Emissivity Material under test Emissivity Asphalt 0 90 to 0 98 Cloth black 0 98 Concrete 0 94 Skin human 0 98 Ceme...

Page 8: ...atteries When the battery icon flashes or when the meter does not switch ON replace the battery The battery compartment is located in the meter handle The battery compartment cover is located just below the trigger Pry the compartment cover loose from the top of the compartment to open the compartment Replace the 9V battery following correct polarity and then close the battery compartment before u...

Page 9: ...power Class 2 1mW 650nm 10nm IR Spectral response 8 14 µm Repeatability 0 5 rdg or 1 C 1 8 F whichever is greater General Specifications Display Backlit LCD with multifunction indicators Response time 150ms Out of range indicator HI for over range Operating temperature 0 C 50 C 32 F 122 F Operating relative humidity 10 90 RH Storage temperature 10 C 60 C 14 F 140 F Storage relative humidity 80 RH ...

Reviews: