Extech Instruments IR255 User Manual Download Page 3

EXTECH

 

INSTRUMENTS

 

3

                                               

IR255

en

EU_V1.4

   

9/14

 

Description

 

 

Meter

 

Description

 

1.

 

LCD

 

Display

 

2.

 

SET

 

Button

 

3.

 

MAX

MIN

 

/

 

Down

 

Arrow

 

Button

 

4.

 

Laser

 

pointer

 

lens

 

5.

 

IR

 

Thermometer

 

lens

 

6.

 

Backlight

Laser

 

Pointer

 

/

 

Up

 

Arrow

 

Button

 

7.

 

Measurement

 

Scan

 

Trigger

 

8.

 

Battery

 

Compartment

 

 

 

Display

 

Description

 

 
 
 
 
 
 
 
 
 
 
 
 

 

Emissivity

 

value

 

indication

 

 

Laser

 

pointer

 

active

 

icon

 

 

Scan

 

mode

 

(active

 

while

 

the

 

trigger

 

is

 

pulled;

 

displayed

 

temperature

 

tracks

 

the

 

temperature

 

of

 

the

 

scanned

 

surfaces)

 

 

Hold

 

mode

 

(displayed

 

temperature

 

freezes

 

with

 

trigger

 

release)

 

 

Maximum/Minimum

 

temperature

 

icons

 

 

Battery

 

capacity

 

indicator

 

(flashes

 

when

 

battery

 

voltage

 

is

 

critical)

 

 

Display

 

Backlight

 

icon

 

 

Temperature

 

units

 

(°F

 

/°C)

 

 

Temperature

 

Alarm

 

icons

 

and

 

audible

 

alarm

 

disable

 

icon

 

 

1

2

3

8

7

6

5

4

Summary of Contents for IR255

Page 1: ...USER GUIDE Mini InfraRed Thermometer With Laser Pointer and High Low Alarms Model IR255...

Page 2: ...ity Audible and visible alarm indication for High and Low Temperature Alarm Safety International Safety Symbols This symbol adjacent to another symbol or terminal indicates the user must refer to the...

Page 3: ...splay Description Emissivity value indication Laser pointer active icon Scan mode active while the trigger is pulled displayed temperature tracks the temperature of the scanned surfaces Hold mode disp...

Page 4: ...laser beam approximately a half inch below the point of test pressing the Laser button again turns the laser off b Select the temperature units o C o F in the Settings Mode see later section c Push t...

Page 5: ...eter is used to enable disable the audible temperature alarm The icon will flash in this mode Use the up and down buttons to toggle the setting When the audible alarm is disabled the display will show...

Page 6: ...ment may be affected by external sources of light In addition the spot size may be so large that it encompasses surface areas not intended to be measured It is necessary to ensure that the size of the...

Page 7: ...spot aim the meter outside the area of interest then scan across in an up and down motion until the hot spot is located Maintenance Cleaning To clean the lenses use compressed air to clear dust and o...

Page 8: ...y if the device is to be stored for longer than 60 days o Never dispose of batteries in a fire Batteries may explode or leak o Never mix battery types Always install new batteries of the same type Nev...

Page 9: ...D distance S spot Laser power Less than 1mW Spectral response 630 to 670 nm wavelength General Specifications Display 1999 count backlit LCD display with function indicators Display rate 250ms approx...

Reviews: