EX710-EU-EN-V3.2-3/12
7
Continuity Measurements
1. Insert the black test lead into the negative
COM
terminal and the red test lead into the
V·
Ω
·CAP·Hz·
positive terminal.
2. Set the function switch to the
•
)
)
)
position.
3. Use
the
MODE
button to select continuity “
•
)
)
)”
. The display icons will change when the
MODE
button is pressed.
4. Touch the test probe tips across the circuit or component under test.
5. If the resistance is < 40
Ω
, a tone will sound.
Diode Test
1.
Insert the black test lead banana plug into the negative COM jack and the red test lead banana
plug into the V·
Ω
·CAP·Hz· positive jack
2.
Turn the function switch to position. Use the MODE button to select the diode function if
necessary (diode symbol will appear on the LCD when in Diode test mode)
3.
Touch the test probe tips to the diode or semiconductor junction under test. Note the meter
reading
4.
Reverse the test lead polarity by reversing the red and black leads. Note this reading
5.
The diode or junction can be evaluated as follows:
•
If one reading displays a value (typically 0.400V to 0.900V) and the other reading
displays
OL
, the diode is good.
•
If both readings display
OL
the device is open.
•
If both readings are very small or ‘0’, the device is shorted.