Introduction

 

Thank

 

you

 

for

 

selecting

 

the

 

Extech

 

EC210

 

conductivity

 

meter

 

which

 

simultaneously

 

displays

 

conductivity

 

and

 

Temperature.

 

Conductivity

 

is

 

measured

 

with

 

a

 

remote

 

electrode

 

that

 

includes

 

a

 

thermistor

 

for

 

measuring

 

temperature.

 

This

 

device

 

is

 

shipped

 

fully

 

tested

 

and

 

calibrated

 

and,

 

with

 

proper

 

use,

 

will

 

provide

 

years

 

of

 

reliable

 

service.

 

Please

 

visit

 

our

 

website

 

(www.extech.com)

 

to

 

check

 

for

 

the

 

latest

 

version

 

of

 

this

 

User

 

Guide.

   

Features

 

 

Three

 

ranges

 

2000uS,

 

20mS,

 

and

 

100mS

 

with

 

auto

 

range

 

functionality

 

 

Conductivity,

 

TDS

 

and

 

temperature

 

measurement

 

functions

 

 

Detachable

 

probe

 

for

 

ease

 

of

 

use

 

in

 

a

 

variety

 

of

 

measurement

 

environments

 

 

User

 

adjustable

 

automatic

 

temperature

 

compensation

 

(set

 

to

 

‘0’

 

for

 

uncompensated

 

Conductivity

 

measurements)

 

 

Carbon

 

rod

 

electrode

 

type

 

for

 

longevity

 

 

LCD

 

display

 

shows

 

Conductivity

 

and

 

Temperature

 

simultaneously

 

 

DATA

 

HOLD

 

for

 

holding

 

displayed

 

reading

 

 

Record

 

and

 

view

 

MIN

 

MAX

 

readings

 

 

Programming

 

mode

 

for

 

selecting

 

o

C/

o

F

 

temperature

 

units,

 

enabling/disabling

 

the

 

auto

 

power

 

off

 

utility,

 

and

 

programming

 

the

 

temperature

 

compensation

 

functionality

 

 

Summary of Contents for EC210

Page 1: ...User Guide Conductivity Meter Model EC210 ...

Page 2: ...er Guide Features Three ranges 2000uS 20mS and 100mS with auto range functionality Conductivity TDS and temperature measurement functions Detachable probe for ease of use in a variety of measurement environments User adjustable automatic temperature compensation set to 0 for uncompensated Conductivity measurements Carbon rod electrode type for longevity LCD display shows Conductivity and Temperatu...

Page 3: ...5 6 7 8 9 Meter Description 1 Main measurement display 2 Temperature reading 3 Power Escape button 4 Function Hold Up arrow button 5 Record Enter button 6 Setting down arrow button 7 Battery compartment rear 8 Probe connection 9 Probe ...

Page 4: ...l show END if the electrode does not detect an appropriate solution value 8 While the CAL icon is flashing use the arrow buttons to adjust the displayed Conductivity reading to match the Conductivity value of the solution 9 After a few seconds the meter will display END Calibration is complete Conductivity Measurements Measurement Preparation Before taking measurements perform the calibration desc...

Page 5: ...ctions on selecting o C o F temperature units and for adjusting the automatic temperature compensation Data Hold Press the Function Hold key to freeze the displayed value The LCD will display HOLD along with the held reading Press the Hold key again to release the data hold function MIN MAX Data Recording When selected the Data Recording function records the Min and Max readings 1 Press the REC bu...

Page 6: ...ture Compensation Percent Setting SEt When the display shows SEt press ENTER SEt will flash and the upper display will show the temperature compensation percent Use the and buttons to set the desired temperature compensation percentage After selecting the desired value press ENTER to save the data The display now shows the temperature units Continue below Temperature Units Select The lower display...

Page 7: ...tall a new 9V battery by snapping the battery terminals onto the wired connectors observing correct polarity and inserting the battery into the compartment lid chamber 5 Install the compartment lid chamber into the meter housing and secure with the two screws Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries ...

Page 8: ...rature 0 to 50 C 32 to 122 F Humidity 80 RH Battery power 9V alkaline battery Power Consumption Approx 6 0 mA DC Weight 295 g 0 65 lbs including batteries probe Dimensions Meter 135 x 60 x 33mm 5 3 x 2 4 x1 3 Probe 22mm 0 87 diameter x 120mm 4 72 length Electrical Specifications Measurement Range Resolution Accuracy Conductivity 20 00mS 100 0mS 2000 uS 0 01mS 0 1mS 1uS 2 FS 1dgt TDS 1 200 12 000 6...

Reviews: