background image

EA80  V2.1H    11/06 

11

Support line (781) 890-7440 

Technical support: Extension 200; E-mail: [email protected] 

Repair & Returns: Extension 210; E-mail: [email protected] 

Product specifications subject to change without notice 

For the latest version of this User’s Guide, Software updates, and other 

up-to-the-minute product information, visit our website: www.extech.com 

Extech Instruments Corporation, 285 Bear Hill Rd., Waltham, MA 02451 

Warranty 

EXTECH INSTRUMENTS CORPORATION

 warrants this instrument to be free of defects 

in parts and workmanship for 

one year

 from date of shipment (a six month limited warranty 

applies to sensors and cables). If it should become necessary to return the instrument for 

service during or beyond the warranty period, contact the Customer Service Department at 

(781) 890-7440 ext. 210 for authorization or visit our website 

www.extech.com

 for contact 

information.  A  Return  Authorization  (RA)  number  must  be  issued  before  any  product  is 

returned to Extech. The sender is responsible for shipping charges, freight, insurance and 

proper  packaging  to  prevent  damage  in  transit.  This  warranty  does  not  apply  to  defects 

resulting  from  action  of  the  user  such  as  misuse,  improper  wiring,  operation  outside  of 

specification,  improper  maintenance  or  repair,  or  unauthorized  modification.  Extech 

specifically  disclaims  any  implied  warranties  or  merchantability  or  fitness  for  a  specific 

purpose and will not be liable for any direct, indirect, incidental or consequential damages. 

Extech's total liability is limited to repair or replacement of the product. The warranty set 

forth  above  is  inclusive  and  no  other  warranty,  whether  written  or  oral,  is  expressed  or 

implied. 

Calibration and Repair Services 

Extech offers repair and calibration services

 for the products we sell. Extech also 

provides NIST certification for most products. Call the Customer Service Department for 

information on calibration services available for this product. Extech recommends that 

annual calibrations be performed to verify meter performance and accuracy. 

 

 

Copyright 

©

 2006 Extech Instruments Corporation 

All rights reserved including the right of reproduction in whole or in part in any form. 

 

 

 

more infor for 

Extech EA80

Phone: 01235 838 555

Email: [email protected]

Web. www.airconcern.co.uk

Air Concern Ltd, Building 173 Curie Avenue Harvell Didcot, Oxfordshire

Summary of Contents for EA80

Page 1: ...User s Guide Indoor Air Quality Meter Datalogger Model EA80 ...

Page 2: ...EA80 V2 1H 11 06 2 Ø2 5 ...

Page 3: ...not hold the instrument close to your face Exhaled CO2 will affect the accuracy of the reading Taking Measurements The sensor for Temperature Humidity Dew Point and Wet Bulb measurements is located in the remote probe Hold the probe in the air in the area to be tested DO NOT immerse in liquid The sensor for CO2 measurements is located on the top of the meter itself Selecting temperature units of m...

Page 4: ...tly on the second display 4 Allow adequate time for readings to stabilize 5 Read the measurements on the LCD Dew Point Temperature Measurement 1 Press the button to power on the meter 2 Press DEW button 3 The display will show the Dew Point Reading on the second display 4 Allow adequate time for the readings to stabilize 5 Read the measurements on the LCD 6 Press DEW button again to exit dew point...

Page 5: ...its stamp time 4 Press MX MN button again The icon will appear with the current value and current time 5 Press MX MN button again cycle through the recorded MAX MIN and current readings 6 Press button to exit this mode 7 Press TIME button exit the time display mode Data Hold 1 Press the H button momentarily to freeze the displayed reading The H icon will appear on the upper left hand side of the d...

Page 6: ...ng and exit this mode Turning Alarm On Off Press ALARM button to turn on the alarm function ALM is displayed When the CO2 value is below the low limit value the meter displays mark and beeps When the CO2 value exceeds the high limit value the meter displays and beeps To exit the ALARM function press ALARM button again Setting the Real Time Clock 1 Press SET button to enter the real time clock sett...

Page 7: ... times the INTV mark is displayed and enter to the setting interval time mode Press or button to select desired interval time from 1 second to 255 seconds Press button to store the setting value and exit this mode Auto Datalogging mode Press and hold MEM button for two seconds 3 beeps the LCD will display and the memory location M will flash each time a recording is made The maximum memory capacit...

Page 8: ... 1 Press button to turn the meter on 2 Place the probe in a known humidity reference for 60 minutes 3 Press the SET button 6 times until SET and CAL are displayed on the LCD 4 Press or button to adjust the display to the reference value 5 Press to store the value and exit the calibration mode Temperature Calibration 1 Press button to turn the meter on 2 Place the probe in a known temperature refer...

Page 9: ...ndensing Dimensions 158 L x72 W x35 H mm 6 22 x2 83 x1 38 Weight approx 255g including batteries Accessories Instruction Manual Battery AC Adaptor Software CD ROM RS232 Cable CO2 Specifications Sensing Range 0 to 6000ppm Sensing Resolution 1ppm Accuracy 101 4 kPa 29 92 inHg and 25 C 77 F 3 of reading or 50ppm whichever is greater Sensing Method Dual wavelength detector with non dispersive infrared...

Page 10: ...nstrument Battery Replacement When the symbol appears on the LCD the six 1 5V AAA must be replaced 1 Turn the meter off 2 Remove the meter s battery cover 3 Replace the batteries observing polarity 4 Affix the battery cover and secure the rear screws RS 232 Interface Software Installation and Operation Software operational instructions are located on the software disc ...

Page 11: ... damage in transit This warranty does not apply to defects resulting from action of the user such as misuse improper wiring operation outside of specification improper maintenance or repair or unauthorized modification Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct indirect incidental or consequential ...

Reviews: