Meter Description 

1. Humidity/Temperature 

Probe 

2. 

Multifunction LCD with bargraph 
and status indicators 

3. 

Power ON/OFF button 

4. MX/MN 

button 

5. 

DATA HOLD button 

6. 

Humidity / Temperature select 
button 

7. SET 

button 

8. 

Units (C/F) select button 

9. MEM 

(memory) 

button 

10. ENTER 

button 

11. READ 

button 

12.  DEW POINT temperature select 

& left arrow button 

13. UP/DOWN 

programming 

keys 

14.  WET BULB temperature select & 

right arrow button 

15.  RS-232 optical jack 
16.  The battery compartment is 

located on the rear of the instrument 

9

3

6

4

7
8

5

2

  

1

Summary of Contents for EA25

Page 1: ...User s Guide EasyView Digital Hygro Thermometer Datalogger Model EA25 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com ...

Page 2: ...ce sensor Temperature thermistor Response Time Humidity 45 to 95 1 min 95 to 45 3 min Temperature Approx 2 seconds for a 10 o C change Reading Rate 2 readings per second RS 232 PC Interface Optical connection with supplied interface cable Software compatible with Windows TM XP Vista and Windows 7 systems Datalogger storage Stores 99 sets of data in manual mode 15 000 in auto mode Sampling Interval...

Page 3: ...button 6 Humidity Temperature select button 7 SET button 8 Units C F select button 9 MEM memory button 10 ENTER button 11 READ button 12 DEW POINT temperature select left arrow button 13 UP DOWN programming keys 14 WET BULB temperature select right arrow button 15 RS 232 optical jack 16 The battery compartment is located on the rear of the instrument 9 3 6 4 7 8 5 2 1 ...

Page 4: ... button allows the user to view the elapsed time for a particular MX or MN reading in Minutes Seconds 59mins 59secs max or Days Hours 99days 24hours max 4 To check the highest and lowest Dew Point or Wet Bulb temperatures use the DEW and the WET buttons 5 The following data displays are available in the MX MN mode Maximum and Minimum Humidity with the associated Temperature Maximum and Minimum Tem...

Page 5: ... has been downloaded otherwise it will be lost Up to 15 000 sets of data can be recorded in automatic datalogging mode ALL of the following settings must be configured before datalogging Real Time Clock Set to the current time in hours minutes and seconds Start Time Set the time that datalogging will automatically begin Stop Time Set the time that datalogging will automatically stop Interval Time ...

Page 6: ...ired minute that datalogging will end 5 Press to move to the two flashing digits representing seconds 6 Press or to set the desired second that datalogging will end 7 Press enter key to store the datalogging stop time and move to the next screen Datalogging Sampling Interval Setting 1 INTV interval appears along with the current interval selection in seconds 2 Use the or buttons to change the numb...

Page 7: ...cations chart earlier in this manual Battery Replacement When the battery power falls low the BT symbol will appear on the LCD Replace the six 1 5 AAA batteries by removing the rear battery compartment screw and accessing the battery compartment Check that the polarity orientation is correct when placing the batteries in the compartment Ensure that the compartment cover is securely fastened when f...