background image

            

 

USER

 

GUIDE

 

 

 

 

Digital

 

CO

 

Monitor

 

 

Model

 

CO30

 

  

Summary of Contents for CO30

Page 1: ...USER GUIDE Digital CO Monitor Model CO30 ...

Page 2: ...n 1 Compensation adjustment 2 Control button 3 AC Adaptor jack 4 LCD Display 5 LED indicator Note Tilt Stand Wall mount access and battery compartment located on rear of meter IMPORTANT SAFETY NOTES The CO30 Carbon Monoxide Monitor is intended for general purpose Air Quality monitoring only and has not been certified for use pursuant to any state or city safety Carbon Monoxide Alarm or Monitoring ...

Page 3: ...oding system to inform the user as to the measured CO concentration Green for Good 10ppm Yellow for Caution 10 to 29ppm Red for Danger 30ppm If the LED fails to illuminate please return the unit for service Control button The Control button located on the left side of the meter is used to control and program a variety of meter functions Press and hold the Control button for at least 3 seconds to a...

Page 4: ...units To save setting press and hold the Control button The meter will return to the normal mode Temperature Compensation Adjustment When is shown on the display press and hold the Control button The factory default 0 0 value will flash Turn the compensation potentiometer clockwise to increase the temperature offset or counterclockwise to decrease offset The range is 5 4 F to 5 4 F 3 0 C to 3 0 C ...

Page 5: ...be compromised Note If the meter displays press the Control button to step to the next setting Alarm Beeper Threshold Selection When is shown on the display press and hold the Control button The factory default setting will flash Momentarily press the Control button to choose a 25ppm 30ppm 35ppm 50ppm 100ppm or 200ppm threshold After the selection press and hold the Control button to save and retu...

Page 6: ...y result Never use the meter with the low battery icon displayed Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dispose of this instrument in household waste The user is obliga...

Page 7: ... RH RH Resolution 1 RH Temperature Accuracy 1 C 1 8 F Relative Humidity Accuracy 5 Alarm functionality Meter beeps and displays the alarm bell icon when the CO level exceeds the alarm setpoint default setpoint is 30ppm user adjustable Temperature and RH Compensation Manual user adjustable CO Calibration Standard user function Zero Calibration Standard user function Power 4 x AAA batteries or suppl...