SAFETY INFORMATION 

 

WARNING

 identifies conditions and actions that may cause hazard(s) to the user; 

CAUTION

 identifies conditions and actions that may damage this Device.   

 
 

Table-1 International Electrical Symbols 

 

AC - Alternating Current 

 

DC - Direct Current 

 

AC and DC - Alternating and Direct Current 

 

Ground 

 

Double Insulation 

 

 

See Explanation In The Manual 

 

To avoid electric shock, injury, or damage to this instrument: 

 

Read this operation manual completely before using this device and follow all safety 
instructions. 

 

This device is for indoor use, altitude up to 2,000m. 

 

Avoid working alone. 

 

Use the device only as specified in this manual; otherwise, the protection provided by the 
meter may be impaired.   

 

Never measure Voltage when the current measurement is selected. 

 

Do not use this device if it looks damaged. 

 

Inspect the leads for damaged insulation or exposed metal. Replace damaged leads. 

 

Disconnect the power and discharge all high-voltage capacitors before testing in the 
resistance, continuity, and diode function. 

 

Use caution when working above 70V DC or 33V RMS and 46.7V peak, these voltages 
may cause a shock hazard. 

 

Always keep your hands behind the protective guard of the probe when measuring. 

 

Select the proper function and disconnect the test leads from test points before changing 
functions. 

 

Do not mix with different types of batteries. Always use specified battery. 

 

The meter is safety-certified in compliance with EN61010 (IEC 1010-1, IEC 1010-2-031) 
Installation Category 

ΙΙ

 250V Pollution Degree 2. 

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176

FAX 781.665.0780 - TestEquipmentDepot.com 

Summary of Contents for CMM-17

Page 1: ...kHz 4 200 20 µ m sec AV µ m sec AV AUTO Quick Start CMM 17 Process Calibrator Multimeter Constant Voltage mA Source Square Wave Auto Scan Ramp Dual Display Multimeter Rechargeable Batteries This guide provides an overview of the meter For more detailed information refer to the CMM 17 User s Guide provided with the meter ...

Page 2: ...Output and Standby control Built in Ni MH rechargeable battery Smart Charger design without battery removal Brightness EL backlight Coarse or Fine output adjust The scale readout for 4 20mA or 0 20mA Adjustable steps and time interval for Auto Scan Adjustable resolutions and start for linear Ramp output 1ms Peak hold to capture inrush voltage and current easily Temperature test with the option of ...

Page 3: ...ure Voltage when the current measurement is selected Do not use this device if it looks damaged Inspect the leads for damaged insulation or exposed metal Replace damaged leads Disconnect the power and discharge all high voltage capacitors before testing in the resistance continuity and diode function Use caution when working above 70V DC or 33V RMS and 46 7V peak these voltages may cause a shock h...

Page 4: ...inals to the device to be tested 6 Press the OUTPUT button The process signal will become active 7 Press the OUTPUT button to return the output to the standby mode Figure 1 Quick Output Operation WARNING Read SAFETY INFORMATION before using this 1 Set switch to M S side 2 Turn the function switch to select combined function 3 Press SHIFT for output setting 4 Use the arrow buttons to set the output...

Page 5: ...entarily to select AC voltage measurement 4 Press the Dual button momentarily to set frequency measuring on secondary display 5 Connect the INPUT terminals by test leads to the source to be tested Figure 2 ACV Hz Measurement 1 Set switch to M or M S side 2 Turn the function switch to V function 3 Press momentarily to select AC voltage test 4 Press momentarily to set frequency measuring on secondar...

Page 6: ...utput for 8 Square wave output for mS 9 Output input units 10 Scan output 11 Ramp output 12 Shift button operation 13 Diode audible continuity 14 Auto range 15 Relative mode 16 Low battery 17 Auto power off icon 18 Data Hold manual trigger 19 Primary display for input 20 Input units 21 Positive negative trigger slope for and mS tests 22 Without ambient temperature compensation 23 4 20 4 20mA 24 0 ...

Page 7: ...n operation for INPUT OFF or OUTPUT ON Press and hold for more than 1 sec to toggle backlit ON OFF Hz Select Hz and Pulse width tests on Primary display Press and hold for more than 1 sec to exit HOLD Freeze existing measured value Press again to trigger next measuring value Press and hold for more than 1sec to exit data trigger hold REL Set the value on the display to be subtracted C F Press and ...

Page 8: ...d output MODE Select output modes for CV CC SCAN and RAMP Select Hz pulse width and Level adjustments for Square wave output SHIFT Press to shift button operation for INPUT OFF or OUTPUT ON Press and hold for more than 1 sec to toggle backlit ON OFF 5 UP 6 DOWN Adjust digit or polarity Press momentarily to increase decrease 1 count for present digit or toggle the polarity of output state M S Provi...

Page 9: ...rements Constant voltage 1 5V 15V 3 DC AC or DC AC mV measurements Constant voltage 1 5V 15V 4 Resistance Continuity measurements Constant voltage 1 5V 15V 5 Diode Audible Continuity Constant current 25 mA Constant voltage 1 5V 15V Constant current 25 mA 6 DC AC or DC AC mA measurements 50mA and 500 mA Square wave output Output and Input Terminals Figure 8 Output Input Terminals 1 2 3 6 5 4 OUTPUT...

Page 10: ...4800 9600 and 19200 Parity None Odd even or none Data bit 8 8 bits or 7 bits Stop bit is always 1 bit ECHO OFF ON or OFF Printer Only OFF ON or OFF Percentage scale 4 20mA 4 20mA and 0 20mA for scale readout Frequency 0 5Hz Set minimum measuring frequency 0 5 1 or 2 Hz Beeper 4800 The driving frequency can be set for 4800 2400 1200 or 600 Hz OFF disables the beeper Temperature C F Four combination...

Reviews: