Maintenance

 

Cleaning

 

and

 

storage

 

1.

 

Meter

 

housing

 

only:

 

Clean

 

with

 

a

 

damp

 

cloth

 

and

 

mild

 

detergent

 

when

 

necessary.

 

Do

 

not

 

use

 

solvents

 

or

 

abrasives.

 

2.

 

Do

 

not

 

attempt

 

to

 

introduce

 

liquid

 

into

 

the

 

vane

 

area

 

when

 

cleaning.

   

3.

 

Store

 

the

 

meter

 

in

 

an

 

area

 

with

 

moderate

 

temperature

 

and

 

humidity.

 

 

Battery

 

Replacement

 

The

 

battery

 

symbol

 

appears

 

on

 

the

 

LCD

 

when

 

the

 

9V

 

battery

 

needs

 

to

 

be

 

replaced.

 

Replace

 

the

 

9V

 

battery

 

as

 

follows:

 

1.

 

Switch

 

the

 

meter

 

OFF

 

if

 

necessary.

 

2.

 

Remove

 

the

 

rear

 

battery

 

compartment

 

cover

 

by

 

sliding

 

the

 

compartment

 

cover

 

downward.

 

3.

 

Replace

 

the

 

9V

 

battery

 

carefully.

 

4.

 

Situate

 

and

 

stow

 

the

 

red

 

and

 

black

 

wires

 

over

 

the

 

top

 

of

 

the

 

battery

 

so

 

that

 

the

 

battery

 

can

 

fit

 

correctly

 

and

 

so

 

that

 

the

 

compartment

 

can

 

close

 

correctly.

 

Use

 

caution

 

to

 

avoid

 

crimping

 

the

 

wires

 

when

 

closing

 

the

 

compartment

 

cover.

  

5.

 

Always

 

re

assemble

 

the

 

meter

 

before

 

operating.

 

 

Never

 

dispose

 

of

 

used

 

batteries

 

or

 

rechargeable

 

batteries

 

in

 

household

 

waste.

 

As

 

consumers,

 

users

 

are

 

legally

 

required

 

to

 

take

 

used

 

batteries

 

to

 

appropriate

 

collection

 

sites,

 

the

 

retail

 

store

 

where

 

the

 

batteries

 

were

 

purchased,

 

or

 

wherever

 

batteries

 

are

 

sold.

 

Disposal:

 

Do

 

not

 

dispose

 

of

 

this

 

instrument

 

in

 

household

 

waste.

 

The

 

user

 

is

 

obligated

 

to

 

take

 

end

of

life

 

devices

 

to

 

a

 

designated

 

collection

 

point

 

for

 

the

 

disposal

 

of

 

electrical

 

and

 

electronic

 

equipment.

  

 

Other

 

Battery

 

Safety

 

Reminders

 

o

 

Never

 

dispose

 

of

 

batteries

 

in

 

a

 

fire.

 

Batteries

 

may

 

explode

 

or

 

leak.

 

o

 

Never

 

mix

 

battery

 

types.

 

Always

 

install

 

new

 

batteries

 

of

 

the

 

same

 

type.

 

WARNING:

 

To

 

avoid

 

electric

 

shock,

 

do

 

not

 

operate

 

the

 

meter

 

until

 

the

 

battery

 

cover

 

is

 

in

 

place

 

and

 

fastened

 

securely.

 

 
 
 
 

Shop for Extech products at:

1.800.561.8187

ShopExtech

.ca

Summary of Contents for AN10

Page 1: ...USER GUIDE Model AN10 Anemometer Shop for Extech products at 1 800 561 8187 ShopExtech ca ...

Page 2: ... Customer Support Safety The probe extending from the top of the meter houses the sensitive air velocity vane sensor do not mishandle shock or allow liquids to come into contact with it The probe sensor can cause personal injury if it is misused or mishandled Use caution when handling this device Do not allow children to handle this device or the accessories and packing materials supplied with it ...

Page 3: ...Unit of measure 6 MAX AVG button also used to change units Note Threaded Tripod mount and Battery Compartment are located on rear of meter not pictured Display Layout 1 Units of measure 2 Air Velocity reading 3 Low Battery symbol 4 Maximum air velocity measurement 5 Average air velocity measurement Shop for Extech products at 1 800 561 8187 ShopExtech ca ...

Page 4: ...meters per hour MAX AVG Recording 1 Press the MAX AVG button momentarily to display the highest air velocity reading maximum recorded The reading shown will be the highest reading measured since the meter was switched ON The MAX icon will appear at the top of the LCD 2 Press the MAX AVG button again to display the average of all air velocity readings AVG taken since the meter was switched ON The A...

Page 5: ...close correctly Use caution to avoid crimping the wires when closing the compartment cover 5 Always re assemble the meter before operating Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Dispos...

Page 6: ...10 to 60 o C 14 to 140 o F 80 RH non condensing Power Supply 9V Battery Battery Life Approx 100 hours Dimensions Weight 135 x 229 x 46mm 5 3 x 9 x 1 8 200g 7 0 oz Copyright 2013 2015 FLIR Systems Inc All rights reserved including the right of reproduction in whole or in part in any form www extech com Measurement Function Range and Resolution Accuracy of reading m s meters per second 1 1 to 20 3 0...

Reviews: