STANDARDS 

PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY 

OVERVOLTAGE CATEGORY I 

Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in 
which measures are taken to limit the transient overvoltages to an appropriate low level. 

Note – Examples include protected electronic circuits. 

OVERVOLTAGE CATEGORY II 

Equipment of OVERVOLTAGE CATEGORY II is energy-consuming equipment to be 
supplied from the fixed installation. 

Note – Examples include household, office, and laboratory appliances. 

OVERVOLTAGE CATEGORY III 

Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations. 

Note – Examples include switches in the fixed installation and some equipment for industrial 
use with permanent connection to the fixed installation. 

OVERVOLTAGE CATEGORY IV 

Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation. 

Note – Examples include electricity meters and primary over-current protection equipment

 

Summary of Contents for AM300

Page 1: ...User s Guide Extech AM300 300A AC Analog Clamp Meter ...

Page 2: ...o not switch to current resistance modes Do not measure current on a circuit whose voltage exceeds 600V When changing ranges always disconnect the test leads from the circuit under test CAUTIONS Improper use of this meter can cause damage shock injury or death Read and understand this user manual before operating the meter Always remove the test leads before replacing the battery or fuses Inspect ...

Page 3: ...I is energy consuming equipment to be supplied from the fixed installation Note Examples include household office and laboratory appliances OVERVOLTAGE CATEGORY III Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations Note Examples include switches in the fixed installation and some equipment for industrial use with permanent connection to the fixed installation OVERVOLTAGE CA...

Page 4: ...ull Scale Resistance 2000Ω 20Ω mid scale 3 of Scale Length Clamp jaw opening 1 5 38mm max Display Analog with Zero Adjustment Input Impedance 240kΩ 75VDC range 530kΩ 300VAC range 1MΩ 600VAC range AC bandwidth 50 to 60Hz 50 to 400Hz for 15 through 300ACA ranges Ambient conditions Temperature 32 104 o F 0 40 o C Relative Humidity 80 Operating Altitude 7000ft 2000m maximum Battery One 1 1 5V AA Batte...

Page 5: ...isplay 4 Press the trigger to open jaw Fully enclose only one conductor For optimum results center the conductor in the jaw 5 The analog display pointer will indicate the current reading AC DC Voltage Measurements 1 Insert the black test lead into the negative COM terminal and the red test lead into the positive V terminal 2 Set the display to the highest AC or DC Voltage range using the thumbwhee...

Page 6: ...log display pointer will indicate the resistance reading Pointer Lock Function The Pointer Lock switch freezes the pointer s position and can be used as a data hold feature This feature is useful in dimly lit or hard to reach locations Maintenance WARNING To avoid electrical shock disconnect the meter from any circuit and remove the test leads from the input terminals before opening the case Do no...

Page 7: ...s responsible for shipping charges freight insurance and proper packaging to prevent damage in transit This warranty does not apply to defects resulting from action of the user such as misuse improper wiring operation outside of specification improper maintenance or repair or unauthorized modification Extech specifically disclaims any implied warranties or merchantability or fitness for a specific...

Reviews: