background image

 

Oyster10-en-US_v2.3   9/15 

12

Garantía

 

FLIR

 

Systems,

 

Inc.

,

 

garantiza

 

este

 

dispositivo

 

marca

 

Extech

 

Instruments

 

para

 

estar

 

libre

 

de

 

defectos

 

en

 

partes

 

o

 

mano

 

de

 

obra

 

durante

 

un

 

año

 

a

 

partir

 

de

 

la

 

fecha

 

de

 

embarque

 

(se

 

aplica

 

una

 

garantía

 

limitada

 

de

 

seis

 

meses

 

para

 

cables

 

y

 

sensores).

 

Si

 

fuera

 

necesario

 

regresar

 

el

 

instrumento

 

para

 

servicio

 

durante

 

o

 

después

 

del

 

periodo

 

de

 

garantía,

 

llame

 

al

 

Departamento

 

de

 

Servicio

 

a

 

Clientes

 

para

 

obtener

 

autorización.

  

Visite

 

www.extech.com

 

para

 

Información

 

de

 

contacto.

 

Se

 

debe

 

expedir

 

un

 

número

 

de

 

Autorización

 

de

 

Devolución

 

(AD)

 

antes

 

de

 

regresar

 

cualquier

 

producto.

 

El

 

remitente

 

es

 

responsable

 

de

 

los

 

gastos

 

de

 

embarque,

 

flete,

 

seguro

 

y

 

empaque

 

apropiado

 

para

 

prevenir

 

daños

 

en

 

tránsito.

 

Esta

 

garantía

 

no

 

se

 

aplica

 

a

 

defectos

 

resultantes

 

de

 

las

 

acciones

 

del

 

usuario

 

como

 

el

 

mal

 

uso,

 

alambrado

 

equivocado,

 

operación

 

fuera

 

de

 

las

 

especificaciones,

 

mantenimiento

 

o

 

reparación

 

inadecuada

 

o

 

modificación

 

no

 

autorizada.

 

FLIR

 

Systems,

 

Inc.,

 

rechaza

 

específicamente

 

cualesquier

 

garantías

 

implícitas

 

o

 

factibilidad

 

de

 

comercialización

 

o

 

idoneidad

 

para

 

cualquier

 

propósito

 

determinado

 

y

 

no

 

será

 

responsable

 

por

 

cualesquier

 

daños

 

directos,

 

indirectos,

 

incidentales

 

o

 

consecuentes.

 

La

 

responsabilidad

 

total

 

de

 

FLIR

 

está

 

limitada

 

a

 

la

 

reparación

 

o

 

reemplazo

 

del

 

producto.

  

La

 

garantía

 

precedente

 

es

 

inclusiva

 

y

 

no

 

hay

 

otra

 

garantía

 

ya

 

sea

 

escrita

 

u

 

oral,

 

expresa

 

o

 

implícita.

 

 

Servicios

 

de

 

calibración,

 

reparación

 

y

 

atención

 

a

 

clientes

 

FLIR

 

Systems,

 

Inc.,

 

ofrece

 

servicios

 

de

 

reparación

 

y

 

calibración

 

para

 

los

 

productos

 

que

 

vendemos

 

de

 

Extech

 

Instruments.

 

Además

 

ofrecemos

 

certificación

 

NIST

 

para

 

la

 

mayoría

 

de

 

los

 

productos.

 

Llame

 

al

 

Departamento

 

de

 

Servicio

 

al

 

Cliente

 

para

 

solicitar

 

información

 

de

 

calibración

 

para

 

este

 

producto.

 

Para

 

verificar

 

el

 

funcionamiento

 

y

 

precisión

 

se

 

debe

 

realizar

 

la

 

calibración

 

anual.

 

Además

 

se

 

provee

 

Soporte

 

Técnico

 

y

 

servicios

 

generales

 

al

 

cliente,

 

consulte

 

la

 

información

 

de

 

contacto

 

en

 

seguida.

 

 

 

Líneas

 

de

 

soporte:

 

EE.UU.

 

(877)

 

439

8324;

 

Internacional:

 

+1

 

(603)

 

324

7800

 

Soporte

 

Técnico

 

Opción

 

3;

 

correo

 

electrónico:

 

[email protected]

 

Reparación

 

/

 

Devoluciones:

 

Opción

 

4;

 

correo

 

electrónico:

 

[email protected]

 

Las

 

especificaciones

 

del

 

producto

 

están

 

sujetas

 

a

 

cambios

 

sin

 

aviso

 

Por

 

favor

 

visite

 

nuestra

 

página

 

en

 

Internet

 

para

 

la

 

información

 

más

 

actualizada

 

www.extech.com

 

FLIR

 

Commercial

 

Systems,

 

Inc.,

 

9

 

Townsend

 

West,

 

Nashua,

 

NH

 

03063

 

USA

 

Certificado

 

ISO

 

9001

 

 

 

Copyright

 

©

 

2013

2015

 

FLIR

 

Systems,

 

Inc.

 

Reservados

 

todos

 

los

 

derechos,

 

incluyendo

 

el

 

derecho

 

de

 

reproducción

 

total

 

o

 

parcial

 

en

 

cualquier

 

medio

 

www.extech.com

 

  

 
  

 

 

www.calcert.com

[email protected]

1.888.610.7664

0

5

10

15

20

25

30

Summary of Contents for 793950050118

Page 1: ...USER GUIDE pH mV Temperature Meter Model OYSTER 10 www calcert com sales calcert co 888 610 7664 0 5 10 15 20 25 30 ...

Page 2: ...ic displays MIN MAX readings audible alerts 5 point buffer recognition Auto Manual temperature compensation This instrument is shipped fully tested and calibrated and with proper use will provide years of reliable service Please visit the Extech Instruments website www extech com to check for the latest version of this User Guide Extech Instruments is an ISO 9001 certified company Meter Descriptio...

Page 3: ...self to the buffer s pH value 1 Connect the pH electrode to the meter s BNC connector input 2 Open the top half of the meter to an appropriate viewing position 3 Power the meter with the POWER CAL button 4 Place the electrode into a buffer solution 5 Press and hold the CAL key until the CAL display icon appears 6 During calibration CAL is shown on the display followed by SA saved 7 When calibratio...

Page 4: ...plug the electrode and rinse it in distilled water 8 Place approx 1 ml of pH 4 solution in the wetting cap before replacing it mV ORP Measurements 1 Note that calibration is not required for mV ORP measurements 2 Use the pH mV button to select the mV mode The display will reflect the unit of measure 3 Remove the wetting cap from the ORP electrode and connect the cable via the BNC meter connection ...

Page 5: ...ory cycle the meter power External Temperature Offset Adjustment The Offset Adjustment is used to fine tune the temperature reading of the external temperature probe This procedure is for the external probe only when ATC is active 1 Place the temperature probe into a known temperature and note any temperature reading error 2 Simultaneously Press and Release the and buttons 0 0 will appear on the L...

Page 6: ...olution shake the electrode with a snap motion to remove residual drops of solution 6 Use part of the sample buffer to be tested next as a rinse solution whenever possible 7 When calibrating use a buffer as close as possible to the expected pH of the sample 8 Keep buffers and samples at the same temperature to avoid temperature effects 9 pH readings stabilize at various rates allow time for readin...

Page 7: ...LCD viewing angle 90 o to 180 o Over range Indication Displays Power 9 volt battery or optional AC adapter Auto Power OFF After 10 minutes of inactivity Low Battery Indication Battery icon appears on LCD Operating Temperature 41ºF to 104ºF 5ºC to 40ºC Storage Temperature 4 o F to 140 o F 20 o C to 60 o C Operating Humidity Max 80 up to 87ºF 31ºC decreasing linearly to 50 at 104ºF 40ºC Storage Humi...

Page 8: ...gulations with regard to battery disposal Never dispose of batteries in a fire Batteries may explode or leak Never mix battery types Always install new batteries of the same type Troubleshooting the Meter Meters are the least likely cause of pH measurement problems To rule out the meter check the following 1 Check the 9V battery and replace it if necessary 2 When using the AC adaptor for power che...

Page 9: ...50 to assure reasonable readings Limit time of measurement Keep probe in the 7 0 buffer between readings Dehydrated membrane Read solution for dry bulb below Dry Bulb Long term storage without wetting Soak electrode tip in wetting cap filled with 1ml 7 00 buffer for 24 to 48 hours Static Charge Wiping electrodes Rinse electrode in 7 0 buffer and blot Do no wipe electrode Same readings in different...

Page 10: ...total liability is limited to repair or replacement of the product The warranty set forth above is inclusive and no other warranty whether written or oral is expressed or implied Calibration Repair and Customer Care Services FLIR Systems Inc offers repair and calibration services for the Extech Instruments products we sell NIST certification for most products is also provided Call the Customer Ser...

Page 11: ...FLIR est limitée à la réparation ou au remplacement du produit La garantie définie ci dessus est inclusive et aucune autre garantie écrite ou orale n est exprimée ou implicite Calibrage réparation et services après vente FLIR Systems Inc offre des services de calibrage et de réparation pour les produits Extech Instruments que nous commercialisons Nous fournissons également une certification NIST p...

Page 12: ...onsabilidad total de FLIR está limitada a la reparación o reemplazo del producto La garantía precedente es inclusiva y no hay otra garantía ya sea escrita u oral expresa o implícita Servicios de calibración reparación y atención a clientes FLIR Systems Inc ofrece servicios de reparación y calibración para los productos que vendemos de Extech Instruments Además ofrecemos certificación NIST para la ...

Reviews: