Extech Instruments 45170CM User Manual Download Page 3

45170CM

en

GB_V1.1

   

1/15

 

3

Measurements

 

A.

 

Air

 

Velocity

 

Measurements

 

1.

 

Use

 

the

 

Mode

 

button

 

to

 

step

 

to

 

the

 

Anemometer

 

mode

 

(An).

 

In

 

Anemometer

 

mode,

 

the

 

display

 

will

 

show

 

Air

 

Velocity

 

and

 

Temperature.

 

2.

 

Press

 

Unit

 

button

 

to

 

select

 

desired

 

unit

 

of

 

measure

 

(FPM,

 

MPH,

 

KNOT,

 

KM/H,

 

or

 

M/S).

 

3.

 

Face

 

the

 

Air

 

Flow

 

Sensor

 

into

 

the

 

source

 

of

 

the

 

air

 

stream.

  

4.

 

Allow

 

time

 

for

 

the

 

reading

 

to

 

stabilize

 

and

 

then

 

note

 

the

 

value

 

on

 

the

 

display.

 

B.

 

Relative

 

Humidity

 

and

 

Ambient

 

Air

 

Temperature

  

Measurements

 

1.

 

Use

 

the

 

Mode

 

button

 

to

 

step

 

to

 

the

 

RH

 

mode

 

(rH).

 

In

 

RH

 

mode,

 

the

 

display

 

will

 

show

 

the

 

Relative

 

Humidity

 

reading

 

(upper

 

right)

 

and

 

the

 

Temperature

 

reading

 

(lower

 

left).

 

2.

 

Press

 

the

 

°

C/°F

 

button

 

to

 

select

 

the

 

desired

 

temperature

 

unit

 

of

 

measure.

 

C.

 

Temperature

 

Measurements

 

Using

 

Type

 

K

 

Thermocouple

 

1.

 

Use

 

the

 

Mode

 

button

 

to

 

step

 

to

 

the

 

Type

 

K

 

Temperature

 

mode

 

(tP).

 

In

 

Temperature

 

mode,

 

the

 

display

 

will

 

show

 

only

 

the

 

thermocouple

 

temperature.

 

2.

 

Plug

 

the

 

thermocouple

 

into

 

the

 

meter's

 

thermocouple

 

input

 

jack

 

on

 

the

 

face

 

of

 

the

 

meter.

 

If

 

no

 

thermocouple

 

is

 

connected,

 

or

 

if

 

the

 

thermocouple

 

is

 

defective,

 

the

 

meter

 

will

 

display

 

dashes.

 

3.

 

Press

 

the

 

°

C/°F

 

button

 

to

 

select

 

the

 

desired

 

temperature

 

unit

 

of

 

measure.

 

D.

 

Light

 

Measurements

  

1.

 

Use

 

the

 

Mode

 

button

 

to

 

step

 

to

 

the

 

Light

 

Meter

 

mode

 

(Light).

 

For

 

convenience,

 

the

 

LCD

 

display

 

is

 

orientated

 

180°

 

from

 

all

 

of

 

the

 

other

 

function

 

displays.

 

2.

 

Press

 

the

 

Lux/Ft

cd

 

button

 

to

 

select

 

Lux

 

or

 

Footcandle

 

units

 

of

 

measure.

 

3.

 

Before

 

making

 

measurements

 

‘zero’

 

the

 

meter

 

by

 

blocking

 

the

 

light

 

sensor

 

(to

 

cause

 

a

 

‘no

 

light’

 

condition)

 

and

 

pressing

 

the

 

Z

 

button.

 

The

 

reading

 

should

 

zero.

  

4.

 

To

 

measure

 

light,

 

position

 

the

 

meter

 

so

 

that

 

the

 

light

 

source

 

shines

 

as

 

directly

 

as

 

possible

 

on

 

the

 

meter’s

 

light

 

sensor

 

dome.

 

Note

 

the

 

reading

 

on

 

the

 

display.

  

E.

 

Airflow

 

(CFM,

 

CMM)

 

Measurements

  

1.

 

Use

 

the

 

Mode

 

button

 

to

 

select

 

the

 

Air

 

Flow

 

mode

 

(AirFL).

 

In

 

Airflow

 

mode,

 

the

 

meter

 

can

 

measure

 

the

 

volume

 

of

 

air

 

moving

 

through

 

a

 

duct,

 

for

 

example.

 

The

 

display

 

will

 

show

 

the

 

CFM

 

(cubic

 

feet

 

per

 

minute)

 

or

 

CMM

 

(cubic

 

meters

 

per

 

minute)

 

unit

 

icon

 

on

 

the

 

bottom

 

of

 

display.

 

Use

 

the

 

UNIT

 

button

 

to

 

toggle

 

CFM

 

and

 

CMM

 

units.

 

2.

 

Press

 

the

 

Area

 

button

 

(A)

 

and

 

then

 

use

 

the

 

and

 

▲▼

 

buttons

 

to

 

program

 

the

 

area

 

value.

 

Press

 

the

 

REC

 

/

 

Enter

 

button

 

to

 

save

 

the

 

area

 

value.

 

See

 

the

 

‘Useful

 

Equations’

 

section

 

for

 

help

 

on

 

calculating

 

the

 

area

 

of

 

a

 

duct

 

or

 

other

 

airway.

 

3.

 

For

 

air

 

flow

 

measurements

 

the

 

area

 

units

 

are

 

meters

 

squared

 

or

 

feet

 

squared.

 

The

 

lower

 

display

 

will

 

show

 

m

2

 

(for

 

CMM)

 

or

 

F

2

 

(for

 

CFM).

  

4.

 

The

 

area

 

setting

 

range

 

is

 

0.001

 

to

 

30.000

 

meters

 

squared

 

or

 

0.01

 

to

 

322.92

 

feet

 

squared.

 

5.

 

After

 

programming

 

the

 

area,

 

face

 

the

 

anemometer

 

sensor

 

into

 

the

 

wind

 

source

 

and

 

note

 

the

 

CFM

 

or

 

CMM

 

air

 

volume

 

reading.

 

Summary of Contents for 45170CM

Page 1: ...USER GUIDE 5 in 1 Environmental Meter with CFM CMM Model 45170CM ...

Page 2: ...m to check for the latest version of this User Guide Product Updates and Customer Support Meter Description 1 Vane Airflow Sensor 2 Type K Thermocouple Input Jack 3 Display 4 Power ESC Button 5 Unit Zero Button 6 C F Lux Ft cd Area Button 7 Light Sensor 8 RH and Air Temperature Sensors 9 Hold Button 10 Rec Enter Button 11 Mode Button Note Battery compartment on back of meter Power ON OFF Press the...

Page 3: ... to the Light Meter mode Light For convenience the LCD display is orientated 180 from all of the other function displays 2 Press the Lux Ft cd button to select Lux or Footcandle units of measure 3 Before making measurements zero the meter by blocking the light sensor to cause a no light condition and pressing the Z button The reading should zero 4 To measure light position the meter so that the li...

Page 4: ...ll automatically turn off after 10 minutes if no keys are pressed during this period Note that the Auto power off function is disabled in the Max Min recording mode Battery Replacement When the low battery icon appears or when the meter will not switch ON please replace the battery The battery compartment is located on the back of the meter secured by a Phillips head screw Open the compartment and...

Page 5: ...0 0 1 4 RH from 10 to 70 RH 4 rdg 1 2 RH 70 RH Light Auto Ranging 0 to 2 200 Lux 1 Lux 5 rdg 8 digits 1 800 to 20 000 Lux 10 Lux 0 to 204 0 Fc 0 1 Fc 170 to 1 860 Fc 1 Fc General Specifications Display Dual Multifunction LCD display Sensors RH Thin film capacitance humidity sensor Temperature Thermistor or optional external Type K Thermocouple Air sensor Low friction vane wheel Light Photo diode w...

Reviews: