38389-en-US_V2.8 4/15
6
Clamp size
Opening 1.3" (33mm) approx.
Diode Test
Test current of 0.3mA typical;
Open circuit voltage 1.5V DC typical.
Continuity Check
Threshold
<50
; Test current < 1mA
Low Battery Indication
“BAT” is displayed
Overrange Indication
“1 “ is displayed
Measurements Rate
2 per second, nominal
Peak detection
Response time < 10ms
Temperature sensor
Type K thermocouple
Input Impedance
7.8M
(VDC and VAC)
Display
3-3/4 digits (4000 counts) LCD
AC bandwidth
50/60Hz (AAC and VAC)
AC response
True rms (AAC and VAC)
Operating Temperature
14 to 122
o
F (-10 to 50
o
C)
Storage Temperature
-14 to 140
o
F (-30 to 60
o
C)
Relative Humidity
90% (0
o
C to 30
o
C); 75% (30
o
C to 40
o
C); 45% (40
o
C to 50
o
C)
Altitude
Operating: 3000m; Storage 10,000m
Over voltage
Category II 600V
Battery
9V
Battery
Auto OFF
After 15 minutes of inactivity
Dimensions/Weight
8x3.2x1.7" (204x80x43mm)/0.62 lbs. (281g)
Safety
For indoor use and in accordance with Overvoltage Category II, Pollution
Degree 2. Category II includes local level, appliance, portable equipment,
etc., with transient overvoltage less than Overvoltage Cat. III