V2.1 03/06
22
RS232 COMMUNICATIONS
Installation
1.
Start the PC.
2.
Insert the Software Program diskette into drive A :
3.
Select "START" and then "RUN" from the Windows menu bar.
4.
Type "A:\ SETUP” in the OPEN box and select "OK"
5.
Follow the installation instructions on the screen.
Initialization
1.
Connect the RS232 cable
between the meter and the
PC's serial port.
2.
Turn the Rotary Switch to
the measurement function
desired.
3.
Press and HOLD the
HELP
RS232
key for 4 seconds to
enable the RS232 output. A
blinking “RS232” will appear
on the display
4.
Select the "MultiScope"
icon in the
START/PROGRAM menu to
launch the program.
Operation
1.
In the "MultiScope" opening screen, select "Setup / Comm port".
2.
Select the proper COM port and click " OK"
3. Setup
Menu:
a.
Select "Setup / Sampling Time" to set the sampling (data record) time for each
measurement. ( 250ms, 500ms, 1s, 2s, 5s, 10s, 30s, 1min, 10min, 30min, 1hr,
10hr, 1day )
b.
Select "Setup: dB " to select the dB reference impedance.
c.
Select "Setup: Baudrate " to select the communications baud rate.
4. View
Menu:
a.
Select "View: Bar " to display the data as a bar plot.
b.
Select "View: Line " to display the data as a line plot.
c.
Select "View: Text " to display the data in a numeric format.
5.
Run Menu: Select Star, Stop or Pause to control the datalogging.
6. File
Menu:
a.
Select "File/Save" to save the recorded data.
b.
Select "File/Open" to open an existing file.
c.
Select "File/Print" to print the file.
7.
To Capture a graphical display:
a.
In the View menu, select either the Line or Bar display (Capture will not occur
with Text display selected)
b.
On the meter, Press HOLD key. The flashing HOLD icon will appear on the
top center of the display and after a five second delay, the captured graphical
display will appear in the display window of the monitor. (The captured display
can be printed or saved to a file).
c.
Capturing a graphical display interrupts the logging session. Press HOLD
once more to exit the capture screen and return to the datalogging screen.
Select RUN then START to resume logging.
查询"381285"供应商