Resistance and Continuity Measurements  

WARNING

: To avoid electric shock or damage to the meter, remove power to the circuit under test and discharge 

all capacitors. 

1)  Set the Function switch to the 

 position. 

2)  Insert the test leads to the meter as follows: Red lead to “V,Hz,

” terminal; Black lead to the 

COM input. 

3)  With the pointed end of the test leads measure resistance. Remember that resistance 

measurements are made in parallel with the device or circuit under test. 

4)  Read the resistance value on the LCD. 
5)  If the resistance is less than 40

, the continuity beeper will sound. 

Frequency Measurements 

1)  Ensure that at least 0.1A AC is detectable with an ACA measurement before measuring 

Frequency. 

2)  Set the Function switch to the Hz position. 
3)  Insert the test leads to the meter as follows: Red lead to “V,Hz,

” terminal; Black lead to the 

COM input. 

4)  With the pointed end of the test leads measure frequency 
5)  Read the Frequency measurement on the LCD in Hz. 

Additional Features 

Relative Measurements 

1)  Press the Zero key and the present measurement will Zero. 
2)  All subsequent measurements are displayed with respect to the zeroed reading. For example, 

if a 20A reading is zeroed and a 30A reading is subsequently measured, the LCD will display 
10A. 

3)  To return to normal operation, press the zero key one more time. 
4)  Note that Relative mode is not available if the MIN/MAX mode is enabled. 
5)  Relative mode is not available in continuity or Hz mode. 
6)  Note that the Zero button is disabled if ohm and continuity or Hz functions are selected. 
7)  LCD displays relative numerical value without bargraph. 

Data Hold 

To freeze a reading on the LCD, press the Data Hold key. The HOLD icon will appear and the 
measurement will be held on the meter’s LCD. To release the Data Hold function and return the 
meter to normal operation, press the Data Hold key again. Data Hold is disabled if ohm and 
continuity function are selected. 

MIN/MAX Reading Mode 

Pressing the MIN/MAX key allows the meter to display ONLY the highest and the lowest readings 
encountered. Press the MIN/MAX key once to view the minimum reading, press it again to view 
the maximum reading. The LCD will toggle between the MIN and MAX values. Press and hold 
MIN/MAX button for more than 2 seconds to return to normal operating mode. Zero function will 
be disabled when MIN/MAX is enabled. MIN/MAX is not available in continuity or Hz mode. 
 

Summary of Contents for 380941

Page 1: ...User Guide AC DC Mini Clamp Meter Model 380941 ...

Page 2: ...aution in its operation The rules listed below should be carefully followed for safe operation 1 NEVER apply voltage or current to the meter that exceeds the specified maximum 2 USE EXTREME CAUTION when working with high voltages 3 DO NOT measure voltage if the voltage on the COM input jack exceeds 500V above earth ground 4 NEVER connect the meter leads across a voltage source while the function s...

Page 3: ...A value on the LCD AC Voltage Measurements WARNING To avoid electric shock or damage to the meter do not make any voltage measurements that exceed the maximum specified 1 Set the Function switch to the VAC position 2 Insert the test leads to the meter as follows Red lead to V Hz terminal Black lead to the COM input 3 With the pointed end of the test leads measure voltage Remember that voltage meas...

Page 4: ...surements are displayed with respect to the zeroed reading For example if a 20A reading is zeroed and a 30A reading is subsequently measured the LCD will display 10A 3 To return to normal operation press the zero key one more time 4 Note that Relative mode is not available if the MIN MAX mode is enabled 5 Relative mode is not available in continuity or Hz mode 6 Note that the Zero button is disabl...

Page 5: ...splay 30 times sec bargraph Weight 225g 8 oz including battery Dimensions 183 x 63 6 x 35 6mm 7 2 x 2 5 x 1 4 HWD Jaw opening 23mm 0 9 Standards IEC 1010 Category III 300V Category II 600V Range Specifications Function Range Resolution Accuracy Overload protect DC Current 40A 10mA 1 0 2dgts 400A DC 0 to 150A 100mA 1 0 2dgts 400A DC 150 to 200A 100mA 2 2 2dgts 400A DC AC Current 50 60Hz 40 to 400Hz...

Page 6: ...bound Battery ordinance to return all used batteries and accumulators disposal in the household garbage is prohibited You can hand over your used batteries accumulators at collection points in your community or wherever batteries accumulators are sold Disposal Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle Cleaning Caution Use only a dry cl...

Reviews: