7.1
General Specifications
Display
4 digit (9999) backlit multifunction LCD
Over range indication
OL
is displayed when air velocity or air temperature
measurements exceed the specified measurement range
Low battery indication
Battery symbol
appears when batteries are low
Reading update rate
Two readings per second
Sensor types
Magnetic induction wind speed sensor and NTC (nega-
tive temperature coefficient) sensor
Meter power
Three (3) 1.5 V (AAA) batteries
Dimensions
6.4 x 2.2 x 1.1 in. (163 x 55 x 28 mm)
Weight
4.2 oz. (118 g)
7.2
Measurement Specifications
Accuracy specifications apply for the following conditions: Temperature:
73.4
℉
± 9
℉
(23
℃
± 5
℃
); Relative Humidity:
≦
80 %
Air Velocity ranges
Resolution
Accuracy (% of reading)
1.5 to 30 m/s (meters per second)
5.4 to 108 km/h (kilometres per hour)
2.9 to 58 knots
3.3 to 67 mph (miles per hour)
295.2 to 5905 ft/min (feet per minute)
1 to 12 Beaufort scale (bft)
0.1 m/s
0.1 km/h
0.1 knots
0.1 mph
0.1 ft/min*
1 bft
*up to 999.9
± (5% + 0.5 digits) m/s
± (5% + 15 digits) km/h
± (5% + 10 digits) knots
± (5% + 10 digits) mph
± (5% + 180 digits) ft/min
± 1 bft
Note: m/s is the standard unit. All other units are calculated from the m/s value.
Air Temperature range
Resolution
Accuracy
14 to 122
℉
(-10 to 50
℃
)
0.2
℉
(0.1
℃
)
± 4
℉
(± 2
℃
)
#NAS100075; r. AA/78827/78827; en-US