background image

Vers. 1.0 / 29.01.21 

 

Ethernet to 2x Serial RS

-

232

 

EX

-

6112

 

Ethernet zu 2x Seriell RS

-

232

 

Manual

 

Anleitung

 

Summary of Contents for EX-6112

Page 1: ...Vers 1 0 29 01 21 Ethernet to 2x Serial RS 232 EX 6112 Ethernet zu 2x Seriell RS 232 Manual Anleitung...

Page 2: ...gung 12 8 Technische Daten 12 9 Technische Zeichnung 13 Inhaltsverzeichnis Index Copyright 2021 by EXSYS Vertriebs GmbH All Rights Reserved 1 Description 13 2 Extent of Delivery 13 3 Layout Connection...

Page 3: ...ngstreiber VCOM der Ihre serielle Anwendung perfekt migriert ohne die Software zu modifizieren Dar ber hinaus k nnen serielle Ger te mit dem Remote Pair Master Slave Modus ber den Peer to Peer Modus m...

Page 4: ...Netzteil Power ACT LED PoE LED TXD LED RXD LED Reset Schalter 3 2 Anschl sse LED s RJ45 Anschluss RJ45 Anschluss Pin Signal Pin Signal Pin Signal 1 BI_DA 4 BI_DC 7 BI_DD 2 BI_DA 5 BI_DC 8 BI_DD 3 BI_...

Page 5: ...erden ca ben tigt Aus Das Ger t ist ausgeschaltet TXD LED rechts Gr n Blinken Die serielle Schnittstelle sendet Daten Aus Die serielle Schnittstelle sendet keine Daten RXD LED links Gr n Blinken Die s...

Page 6: ...Ger teserver Werkseinstellung Der EX 6112 wird mit folgenden Werkseinstellungen ausgeliefert Login User Name admin Password system IP Address DHCP Automatisch zugewiesen Network Operation Mode VCOM M...

Page 7: ...itgelieferte VCOM Admin Utility vspsetup exe installieren Das Installationsprogramm befindet sich auf der im Lieferumfang enthaltenen Treiber CD in folgendem Ordner Wichtig Bitte f hren Sie das Instal...

Page 8: ...d 6 VCOM Admin Utility 2 Zuordnung der COM Ports Um den virtuellen COM Anschluss zu erstellen und dem seriellen Ger t zuzuordnen klicken Sie auf COM Mapping Add COM OK Um die COM Port Nummer zu ndern...

Page 9: ...lte nun folgender Eintr ge im Ger temanager sichtbar sein 3 ndern der Einstellungen der seriellen Schnittstelle Wenn Sie die Einstellungen der seriel len Schnittstelle auf andere Werte als die Standar...

Page 10: ...Utility Nachdem Sie eingeloggt sind klicken Sie auf Remote Device Management und dann Doppelklick auf den ausgew hlten Device Server in der Liste Doppelklick Klicken Sie auf Remote Device Management D...

Page 11: ...Modbus UDP TCP Client als den Standard VCOM Modus ndern m ssen Sie stattdessen den Webbrowser verwenden Um das Web Konfigurationsmen zu ffnen klicken Sie auf Remote Device Management w hlen Sie Device...

Page 12: ...sfer Rate 50 bis 921 6 Kbps Baud Rate Anschl sse 2x 9 Pin D SUB serieller Stecker 1x RJ45 Ethernet Anschluss 1x 12V DC Buchse 1x Terminal Block 5 24V Hardwaresystem Ethernet 10 100 Mbit s VCOM Admin U...

Page 13: ...provides a virtual COM port redirection driver VCOM that perfectly migrates your serial application without modifying the software In addition serial devices with remote pair master slave mode can com...

Page 14: ...included Power Supply Power ACT LED PoE LED TXD LED RXD LED Reset Button 3 2 Connections LED s RJ45 Port RJ45 Port Pin Signal Pin Signal Pin Signal 1 BI_DA 4 BI_DC 7 BI_DD 2 BI_DA 5 BI_DC 8 BI_DD 3 B...

Page 15: ...power up Off The unit is not booted yet TXD LED right Green Blinking The Serial Port is sending out data Off The Serial Port is not sending out any data RXD LED left Green Blinking The Serial Port is...

Page 16: ...5 Configuration of the Device Server Factory Settings The EX 6112 is delivered with the following factory settings Login User Name admin Password system IP Address DHCP Assigned Automatically Network...

Page 17: ...IP address you must install the VCOM Admin Utility vspsetup exe that comes with the device The installation program is located on the driver CD included in the scope of delivery in the following fold...

Page 18: ...H All Rights Reserved 6 VCOM Admin Utility 2 Assignment of COM Ports To create the virtual COM Port and assign it to the serial device click COM Mapping Add COM OK To change the COM Port number click...

Page 19: ...ager The following entry s should now be visible in the device manager 3 Changing the settings of the serial interface If you change the settings of the serial interface to values other than the defau...

Page 20: ...GmbH All Rights Reserved After you are logged in click Remote Device Management and then double click the selected device server in the list Click Remote Device Management double click on the selected...

Page 21: ...operation mode to other modes e g Modbus UDP TCP Client than the default VCOM mode you must use the web browser in stead To open the web configuration menu click Remote Device Management select Devic...

Page 22: ...al Information 9 Technical Drawing Data Transfer Rate 50 to 921 6 Kbps Baud Rate Connectors 2x 9 Pin D SUB serial Connector 1x RJ45 Ethernet Port 1x 12V DC Connector 1x Terminal Block 5 24V Hardware S...

Page 23: ......

Page 24: ......

Reviews: