Cleaning
Turn off the mains to the equipment before carrying out any maintenance and wait for it cool down. We
advise using lukewarm water and detergents to clean enameled elements.Never use abrasive products.
Rinse the glass worktop with water and dry using a soft cloth. Use sponges or a moist cloth to clean the
tops, and remember that water in excess can damage the electric elements. Clean tough stains using
non abrasive detergents, or warm vinegar.
Clean the electric tops using a moist cloth, then lightly oil the the top when it is still warm.
Only licensed repairers should service the appliance.
Installation
Fitting guidelines
The voltage rating of the hob heating elements is 220-240V .Appliance with three-pole cable are set
upfor operation current at the voltage and frequency indicated on the rating plate Look at the connection
wiring diagram.The earth conductor is yellow/green. The connection to the electricity supply must be
made by a qualified person and followingthe regulations in force. When the appliance is to be installed
above a built-in oven,the two apliances must be connected separately, to make it easier to take the
appliances out and for electrical safety.
5
Recommended type of
connection lead
E
L1
L
L
L2
N
N1
N
N2
CONNECTION DIAGRAM
Caution! Voltage of heating
elements 220-240V Caution! In the event
of any connection the safety Wire
must be connected to the E terminal.
L1
N1 N2
L2
• If the cable is damaged or to be replaced, the operation must
be carried out the by a service agent or a suitably
qualified professional.
• If the appliance is being connected directly to the mains, an
omnipolar circuit breaker must be installed with a minimum
opening of 3mm between contacts.
•
The installer must ensure that the correct electrical connection has been made and that it is compliant with all
applicable standards and safety regulations.
•
The cable must not be bent or compressed.
•
The cable must be checked regularly and replaced by authorised technicians only.
This appliance is equipped with a five
-pole cable
suitable
for
electrical connection to
alternating current
at the voltage and frequency indicated on the rating plate Look at the connection wiring diagram. The
earth conductor is yellow/green. The connection to the electricity supply must be made by a qualified
person and following the regulations in force.
When the
appliance is to be installed above a built-in oven, the two appliances must be connected
separately. The supply cable must be so positioned that no point can reach a temperature 50°C higher
than ambient temperature. Also check that the supply system has an effective earth connection and
corresponds to the standards in force and that the breaker can be reached easily when the appliance is
installed.