Express Water EZRO5 Installation Manual Download Page 7

12

13

Tubing Quick Connect Guide

To Cut Tubing

M

ake your cuts against a flat cutting surface with a razor blade, or use a handheld tube cutter. Any cuts to 

your Tubing must be perfectly straight. 

NOTE!

Improperly cut Tubing may leak water or fail to lock into Fittings.

Wait until all elements of your RO System are in their final locations before cutting your Tubing. 

Make sure you measure the length you will need before cutting.

Attach Tubing

Push Tubing in straight and level with the 

Collet. The Tubing will go 5/8ths of an inch 

into the Collet before the lock is activated. 

Pull out on the Tube to make sure the lock 

has activated and the Tubing is secure.

NOTE! 

Once connected, make sure to 

check tubing is secure.

5/8”

5/8”

Insert or Remove Locking Clips

To lock a Tube in place make sure the 

Tubing is fully inserted then slide the open 

end of the Clip between the Collet and 

Fitting. The Clip must be removed before 

the Tubing can be removed. To remove 

the Clip pull away until it slides out from 

between the Collet and Fitting.

Unlocked

Locked

The tubing in your RO System uses a Quick Connect locking mechanism to 

lock the Color Coded Tubing in place. Be careful not to damage your tubing 

as you unpack it. 

NOTE! 

Make sure to remove any plugs before attempting to insert tubing.

Plug

Collet

Locking

Clip

Fitting

Release Tubing/Plugs

If there is a Locking Clip on the Collet it must 

be removed before the Tubing can be released. 

Push and hold the Collet in to release the lock 

while pulling out on the Tube/Plugs.

NOTE! 

Collet must be held down while 

pulling up on the tube to release the tube.

Hold 

Down

Pull 

Up

Installation

1.

 Identify if your faucet is compatible with the 13/16” 

female threaded diverter valve

 

- I

f it is not compatible you may need the 13/16” 

male to 13/16” male adapter -or the- 15/16” male to 13/16” 

male adapter

 

- I

f your faucet is not compatible with either of these 

adapters you will need to purchase an appropriate adapter 

to connect your faucet to the diverter valve

1.

 Push the RO Faucet stem into the Faucet Adapter on the 

Post Activated Carbon Filter

2.

 Make sure the faucet is fully pushed in

CAUTION!

The water supply to the unit 

MUST

 be 

COLD WATER ONLY

. Using 

HOT WATER

 will severely damage 

your RO System.

2.

 Screw on Diverter Valve 

(with appropriate adapters 

if needed)

3.

 Remove the black 

plug from the Union 

Connection and insert the 

Black Tubing

4.

 Remove the blue 

plug from the Sediment 

Filter and insert the 

White Tubing

5.

 Check to make sure 

tubes are fully inserted

15/16” to 13/16”

13/16” to 13/16”

Diverter Valve

RO Faucet

Summary of Contents for EZRO5

Page 1: ...Customer Support 1 800 992 8876 RO Countertop System Installation Manual ...

Page 2: ...t solution for safe clean water in your home We know life isn t always so simple though If you have questions during your setup we can help Just give us a call during normal business hours at 1 800 992 8876 Monday Friday 10am 5pm PST Connection Points A to B Connect the WHITE Tubing from the Diverter Valve Out Point A to the Sediment Filter s IN Point B C to D Connect the BLACK Tubing from the Div...

Page 3: ...e and local laws and codes regarding plumbing even if they differ from what is stated in this manual If your state law requires use a professional licensed installer or plumber who meets the requirements of this system All o rings fittings filter canisters and teflon tape wears out after a certain period of time The lifetime of your components are subject to change with the quality of the water su...

Page 4: ...g Quick Connect Guide Installation Diverter Valve RO Faucet Using the System System Startup System Maintenance Filter Change Instruction Troubleshooting FAQ Warranty Page 8 Page 10 Page 11 Page 12 Page 13 Page 13 Page 14 Page 14 Page 15 Page 15 Page 16 Page 17 Page 18 ...

Page 5: ...running right away just remove your aerator and screw the diverter valve on We support 13 16 male threaded faucets 13 16 female threaded faucets and 15 16 female threaded faucets If you have another type of faucet you will need to visit a home or plumbing supply store to adapt from your faucet type to 13 16 male as the diverter valve is 13 16 female Get Ready for Pure Water The flow through your f...

Page 6: ...hite Tubing 3ft Diverter Valve Female 13 16 Fits 13 16 male thread Faucet Adapters 13 16 Male to 13 16 Male 15 16 Male to 13 16 Male Black Tubing 3ft Locking Clips Push Fit RO Faucet System Diagram 1 Diverter Valve 2 System Feed Tube 3 System Drain Tube 4 Sediment Filter 5 Stem Elbow 1 4 6 Granular Activated Carbon Filter 7 Male Elbow 1 8 8 RO Membrane Housing 9 Drain Flow Restrictor 10 Union Conn...

Page 7: ... damage your tubing as you unpack it NOTE Make sure to remove any plugs before attempting to insert tubing Plug Collet Locking Clip Fitting Release Tubing Plugs If there is a Locking Clip on the Collet it must be removed before the Tubing can be released Push and hold the Collet in to release the lock while pulling out on the Tube Plugs NOTE Collet must be held down while pulling up on the tube to...

Page 8: ...to sit in The system will release water when it is disassembled 2 Make sure that water flow to the system is off 3 Place the RO System in the bucket or a sink and disconnect the the elbows from each side of the SED GAC and PAC filters For detailed directions of disconnecting these refer to the Quick Connect Guide Page 12 One side of the SED has an inflow tube instead of an elbow One side of the PA...

Page 9: ... the system is 45 and the maximum PSI is 80 If your PSI is too high you can purchase a Pressure Regulator to reduce your pressure to acceptable levels Let us walk you through these options call us at 1 800 992 8876 Monday Friday 10am 5pm PST or visit expresswater com Does this unit soften water Your RO System will soften water However hard water does reduce the lifespan of your filters What is the...

Page 10: ... year from the date of original purchase Not Covered This warranty does not cover labor for removal or installation accumulation of dirt or grime you are responsible for your own cleaning systems with the serial number removed or altered damage from improper storage high or low temperature sun damage etc damage from a system not installed as instructions directed anyone other than original purchas...

Page 11: ......

Reviews: