LED4
LED Scan rate
600Hz
Default:1200Hz
1200Hz
2000Hz
4000Hz
25KHz
Main functions
1. address:Current DMX address
A.Setting DMX address by button
press
ENTER
button when show the
address
menu, then adjust
the DMX address by pressing
[UP]
or
[DOWN]
button
Press
[ENTER]
to confirm or pressing
[ESC]
to return to main
menu
.
B.Setting DMX address by controller
1.
Set the DMX value of channel 5 to 10-15,channel 17 to 20-26,
channel 7 to 30-36,channel 8 to 40-46,then the devices
connected to the controller will enter to the setting address
mode
2.
Set the DMX value of
channel 1
from 0-59,then you will see
the the first number of the Address change to (channel 1
vaule)/10.
For example
,when set the value of channel 1 to 20,the first
DMX address number will be 2(20/10=2) ,
3.
Set the DMX value of
channel 2
from 0-99,then you will see
the the sencond number of the Address change to (channel 2
vaule)/10.
For example
,when set the value of channel 2 to 30,the first
DMX address number will be 2(30/10=3) ,
4.
Set the DMX value of
channel 3
from 0-99,then you will see
the the third number of the Address change to (channel 3
vaule)/10.
For example
,when set the value of channel 1 to 40,the first
DMX address number will be 3(40/10=4) ,
And the DMX address you set by conctroller will be 234.
5.
Set the DMX value of
channel 4
to 255,then you will save
the DMX address setted by the controller.
Caution: It won’t save the address if the address number is