background image

 

LED4 

 

 

LED Scan rate 

600Hz 

 

Default:1200Hz 

 

1200Hz 

 

2000Hz 

 

4000Hz 

 

25KHz 

 

 
 
Main functions 

 

1. address:Current DMX address 
  A.Setting DMX address by button 

press 

ENTER 

button when show the 

address

 menu, then adjust 

the DMX address by pressing 

[UP]

 or 

[DOWN]

 button 

Press 

[ENTER]

 to confirm or pressing

 [ESC]

 to return to main 

menu

B.Setting DMX address by controller 

1.

Set the DMX value of channel 5 to 10-15,channel 17 to 20-26, 

channel 7 to 30-36,channel 8 to 40-46,then the devices 
connected to the controller will enter to the setting address 
mode  

2.

 Set the DMX value of 

channel 1

 from 0-59,then you will see 

the the first number of the Address change to (channel 1 
vaule)/10. 

For example

,when set the value of channel 1 to 20,the first 

DMX address number will be 2(20/10=2) , 

3.

 Set the DMX value of 

channel 2

 from 0-99,then you will see 

the the sencond number of the Address change to (channel 2 
vaule)/10. 

For example

,when set the value of channel 2 to 30,the first 

DMX address number will be 2(30/10=3) , 

4.

Set the DMX value of 

channel 3

 from 0-99,then you will see 

the the third number of the Address change to (channel 3 
vaule)/10. 

For example

,when set the value of channel 1 to 40,the first 

DMX address number will be 3(40/10=4) , 
And the DMX address you set by conctroller will be 234. 

5. 

Set the DMX value of 

channel 4 

to  255,then you will save 

the DMX address setted by the controller. 

Caution: It won’t save the address if the address number is 

 

Summary of Contents for TourBlinder 400

Page 1: ...PRE MANUAL RAWMNLeng V201705 001 nderungen sind ohne Ank ndigung m glich Changes are possible without prior notice Tour Blinder 400 led80050...

Page 2: ...1 Dimensions...

Page 3: ...m W 193mm Weight 9Kg l IP65 SAFETY INSTRUCTIONS This device has left the factory in perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for...

Page 4: ...r will not accept liability for any resulting defects or problems DMX 512 control connection The product has a DMX 512 input fitted with 3 pin XLR connectors Screened cables in compliance with EIA RS...

Page 5: ...Backlight contr ol Keep screen on Exit the main menu black light will be closed after 10 20 30 second without operation 10 S 20 S 30 S System info Auto test Auto test Hour Xx hour Software version V1...

Page 6: ...umber of the Address change to channel1 vaule 10 For example when set the value of channel 1 to 20 the first DMX address number will be 2 20 10 2 3 Set the DMX value of channel 2 from 0 99 then you wi...

Page 7: ...mode press ENTER button when show the key mode menu then select lock or unlock by pressing UP or DOWN button Show Temperature press ENTER button when show the Temp Uint CS menu select the way of show...

Page 8: ...lor mode then adjust the color by pressing UP or DOWN button 6 Auto test press ENTER button when show the auto test menu select test mode by pressing UP or DOWN button DMX functions and values 1CH Mod...

Page 9: ...obe 000 010 NoFunction 011 132 Strobe Slow to fast 133 255 Macro Strobe Slow to fast 4 LED head 1 000 255 0 100 5 LED head 2 000 255 0 100 6 LED head 3 000 255 0 100 7 LED head 4 000 255 0 100 8 Auto...

Reviews: