INSTALLATION
220~240V: 60 units may be connected in series
110~120V: 30 units may be connected in series
NOTE!
If the signal cable is over 60 m between the DMX512 controller
and fixture or beween two fixtures, then a DMX signal amplifier is
needed as well.
HANGING:
The fixture can be
mounted in a hanging position
using the supporting bracket.
The bracket should be secured
to the mounting truss or struc-
ture using a standard mount-
ing clamp. Please note that
when hanging the unit a safety
cable should also be used.
UPRIGHT:
The fixture can
be mounted in an upright
or sitting position using the
supporting brackets.
MOUNTING
POWER CONNECTIONS
DMX-SIGNAL AND TERMINATION
2.0
2.1
2.2
2.3
Termination reduces signal errors and avoids
signal transmission problems and interface. It
is always advisable to connect an DMX termi-
nal. Resistance 120 Ohm (1/4 W) between PIN 2
(DMX) and PIN 3 (DMX +) of the last fixture.