10
QUARTZ
CLASSIC
Important:
Be careful to not damage any panels and electronic components while disassembling the machine.
The power cord must be unplugged when disassembling the machine.
Remove the four screws form the cup shelf.
Remove the screw at the top of the rear panel,
then remove it.
INSTALLATION AND START-UP
Note:
If you want to disconnect the machine from the mains water supply and start using only the internal
water tank again, make sure to replace the inlet valve cover plug. The machine will leak if this plug is
not reinstalled.
01
02
i
To prepare the machine for connection to an external water supply follow the connection procedure
explained below.
Connecting the machine to the domestic water supply must performed by a qualified person.
Run about 20 liters of water from the domestic water supply before connecting the machine to make sure
there are no contaminants in the plumbing system.
Connect the flexible inlet hose (included in the accessory box) to the domestic water supply and tighten it
with a wrench. The hose only connects to a ½” male connection.
Only use safe drinking water with a hardness rating between 5 - 8ºTH (French hardness degress) / 2.8 -
4.5ºdH (German hardness degrees ) / 3.5 - 5.6ºe (English hardness degrees) / 50 - 80 ppm (parts per million)
of calcium. If the hardness value is below this limit, corrosion of hydraulic components is likely. If the value is
higher, lime-scaling inside the boiler will occur. In both cases, the proper function of the machine and quality
and taste of the coffee will be negatively affected.
If you choose to connect the machine to an external water connection, it is strongly recommend to connect
the drip tray to an external drain. See page 11 for more information.
Connecting to the domestic water supply
Summary of Contents for Quartz Classic One Touch
Page 1: ...R TM_EN Part No 1764264_05 QUARTZ CLASSIC TECHNICAL MANUAL...
Page 30: ...30 QUARTZ CLASSIC Machine Drawing EXPLODEDVIEW 06 05 14 04 03 02 10 08 11 13 12 01 09 07...
Page 36: ...36 QUARTZ CLASSIC Manifold system Drawing EXPLODEDVIEW 01 10 10 11 12 13 11 03 04 05 06 07 02...
Page 46: ...46 QUARTZ CLASSIC Water tank Drawing 01 02 03 04 05 EXPLODEDVIEW 06...
Page 48: ...48 QUARTZ CLASSIC 01 02 07 06 02 05 04 03 08 Water tap Drawing 09 10 EXPLODEDVIEW 13 12 11...