6.
Maintenance and troubleshooting
6.1
General
The
exodraft
Inline fan is designed for prolonged use, and no regular maintenance is required. This specifically applies
in case it is being used with fuel oil. The Inline fan is designed to make this an easy task. The front part of the venter has
the motor and impeller mounted on it, and it slides out to provide easy access.
The CFI should be inspected periodically (at least once a year) for leakage, and cleaned, if needed.
6.2
Preparing the inline fan for cleaning
Referring to fig. 11 below, follow these steps to open the CFI inline fan so it can be cleaned and inspected:
1. Use removable lifting eyes for disassembly and assembly of motor section. (CFI300 & CFI350)
2. Remove the four hex nuts holding the motor mounting plate to the housing.
3. Motor and impeller assembly can be lifted out of the housing. See table listing weights for each model.
4. Clean the impeller and inside of the housing as needed.
5. Replace the motor and impeller assembly and tighten hex nuts to secure motor section.
Remove (4) hex nuts before
removing motor/impeller assembly
Fig. 11
NOTE
The approximate weights of the CFI motor/impeller assemblies are as follows:
CFI300-41 19 Kg
CFI350-41 21 Kg
CFI400-42 32 Kg
CFI500-42 48 Kg
WARNING
Do not open the housing unless power to the CFI Inline fan has been disconnected from power supply.
3110067 CFI 300-500 UK 290415
12
• Maintenance and troubleshooting