Troubleshooting
Troubleshooting
Important:
It is essential that all operator safety mechanisms be connected and in proper operating
condition prior to use.
When a problem occurs, do not overlook the simple causes. For example: starting problems could be caused
by an empty fuel tank.
The following table lists some of the common causes of trouble. Do Not attempt to service or replace major
items or any items that call for special timing of adjustments procedures (such as valves, governor, etc.). Have
this work done by your
Engine Service Dealer
.
Note:
When disconnecting electrical connectors Do Not pull on the wires to separate the connectors.
Problem
Possible Cause
Corrective Action
1. Parking brake is not engaged.
1. Engage the parking brake.
2. Brake switch not adjusted properly.
2. Adjust the brake switch.
3. Battery does not have a full charge.
3. Charge the battery. See
Check
Battery Charge
and
Recommended
Jump Starting Procedure
sections in
Maintenance.
4. Electrical connections are corroded, loose
or faulty.
4. Check the electrical connections for
good contact. Clean connector terminals
thoroughly with electrical contact cleaner,
apply dielectric grease and reconnect.
5. Fuse is blown.
5. Replace the blown fuse.
Starter does not crank.
6. Relay or switch is defective.
6. Contact an Authorized Service Dealer.
1. Fuel tank is empty.
1. Fill the fuel tank.
2. Fuel shutoff valve is closed.
2. Open the fuel shutoff valve.
3. The throttle and choke are not in the
correct position.
3. Be sure the throttle control is midway
between the “SLOW” and “FAST”
positions, and the choke is in the “ON”
position for a cold engine or the “OFF”
position for a warm engine.
4. Dirt in fuel filter.
4. Replace the fuel filter.
5. Dirt, water, or stale fuel is in the fuel
system.
5. Contact an Authorized Service Dealer.
6. Air cleaner is dirty.
6. Clean or replace the air cleaner element.
7. Electrical connections are corroded, loose
or faulty.
7. Check the electrical connections for
good contact. Clean connector terminals
thoroughly with electrical contact cleaner,
apply dielectric grease and reconnect.
8. Relay or switch is defective.
8. Contact an Authorized Service Dealer.
9. Faulty spark plug.
9. Clean, adjust or replace spark plug.
Engine will not start, starts hard, or fails to
keep running
10. Spark plug wire is not connected.
10. Check the spark plug wire connection.
1. Engine load is excessive.
1. Reduce the ground speed or aeration
depth.
2. Air cleaner is dirty.
2. Clean or replace the air cleaner element.
3. Oil level in the crankcase is low.
3. Add oil to the crankcase.
4. Cooling fins and air passages for the
engine are plugged.
4. Remove the obstructions from the cooling
fins and air passages.
5. Dirt in fuel filter.
5. Replace the fuel filter.
Engine loses power.
6. Dirt, water, or stale fuel is in the fuel
system.
6. Contact an Authorized Service Dealer.
35
Summary of Contents for SAR481KA30
Page 1: ...STAND ON AERATOR For Serial Nos 312 000 000 Higher Part No 4501 251 Rev A...
Page 11: ...Safety 116 6459 116 6460 116 6462 116 6990 116 7709 11...
Page 37: ...Schematics Schematics Electrical Diagram 37...
Page 38: ...Schematics Electrical Schematic 38...
Page 39: ...Schematics Hydraulic Diagram 39...
Page 41: ...Service Record Date Description of Work Done Service Done By 41...
Page 42: ...42...